Loading...
HomeMy WebLinkAboutLot Certifications - 03/11/2015Utilities ���� j ®¢ electric • stormwater • wastewater • water F6rts Collins Box 580 FoowooPO Fort Collins,s, CO 80522 970.221.6700 970.221.6619619 fax 970.224:6003 TDD utilities0tcgov.com • Icgov.convutilifles CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) W e ee'a0Wo.1 nh7/Z044' Date: 03/26/15 e41'rV%> t+JUn. J 0A =/IfIzo -C Permit Application No. B1402269 Address: 538 Caietan Street Lot: 10 Block: 9 Subdivision: Old Town North Subdivision I,(Print) Wyatt M. Knutson , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): 03/26/15 -, accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the lottsite are insubstantial conformance with the City approved drainage and grading plan for the properly (information attached). SEE NOTE. ® The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormw on and off the lot/site in a manner consistent with the approved drainage plan. SEE _ e..�/ra By: CO NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the lottsite, including but not limited to drawings of the lottsite showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written Informationlexplanation of discrepancies, and other Information necessary to confirm the above certification to: 121 Final Grade Assurance Observation: C T L I T H O M P S O N Per the client's request, a representative of CTL has visually observed and measured elevations of the grading aruond the home at the site referenced below. The following summarizes our observations and opinions at the time of our visit. Client : FR Development Site Address: 538 Cajetan Street Job#: WY00924.000 Lot: 10 Block: 9 Date: 3/26/2015 Contact: Kevin Dewlen Subdivision/filing: Old Town North Background Information: Referenced Grading Plan: Shear Engineering Corporation Dated: Jobs: STA# MEASUREMENT ELEVATION REMARKS 1 0.00 63.11 BM/Prop. Corner 2 -0.35 62.76 Prop. Corner 3 -0.05 63.06 4 2.20 65.31 5 4.80 67.91 Fin. Floor 6 2.65 65.76 7 2.15 65.26 8 2.40 65.51 High Point 9 2.85 65.96 10 0.85 63.96 11 0.70 63.81 12 0.55 63.66 Prop. Comer 13 0.10 63.21 Prop. Corner 14 0.90 64.01 15 0.05 63.16 16 2.60 65.71 17 0.25 63.36 18 19 20 21 22 Site: //���5✓ all North S mmar of opinions; It is our opinion that the top of foundation and grades around the home are consistent with the above referenced grading plan or are a functionally . adequate substitute. ❑ Rejected (2nd observation required) Corrective action: CTL I Thompson, Inc. 1 1103 Old Town Lane, Cheyenne, WY 82009 JOB t61. 225-01-26-01 DATE 05/28/14 SCALE 1 "-20' BRAWN RS C,wwn Zvfnflerill llc Structural E ineerin9 4 Ins�su tons 524 Stover St. Phone: (970) 498 — 9537 Fart Collins, Colorado 80524 Cell: (970) 691 — 4239 reya sTSQmsn.aom SITE PLAN LOT AREA = 3,401.44 SF FR .DEVELOPMENT LOT 10. BLOCK 9, 538 CAJETAN OLD TOWN NORTH SUB. No Text