Loading...
HomeMy WebLinkAboutLot Certifications - 11/17/2014Utilities City�� electric• stormwater. wastewater. water Forst Collins '°OW°on PO Box 580 Fort Collins,, CO 80522 970.221.6700 970.221.6619 lax • 970.224.6003 TOO ulililiesofcgov.com • /cgov.com/ufi1Xes CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: 03/26/15 Permit Application No. B1402689 Address: 532 Caietan Street Lot: 11 Block: 9 Subdivision: Old Town North Subdivision Co "ao,.ved on U A7 no+ "crow rA or,%J on 3/91/2Dr4l I,(Print) Wyatt M. Knutson , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): 03/26/15 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the lodsite are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. ® The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormw it pd off the lot/site in a manner consistent with the approved drainage plan. SEE N ` — M By: Co NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the lot/site, Including but not limited to drawings of the lot/site showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written Informationtexplanation of discrepancies, and other Information necessary to confirm the above certification to: Final Grade Assurance Observation: C T L I T N 0 M P S® N Per the client's request, a representative of CTL has visually observed and measured elevations of the grading aruond the home at the site referenced below. The following summarizes our observations and opinions at the time of our visit. Client: FR Development Site Address: 532 Cajetan Street Job#: WY00924.000 Lot: 11 Block: 9 Date: 3/26/2015 Contact: Kevin Dewlen Subdivision/filing: Old Town North Background Information: Referenced Grading Plan: Shear Engineering Corporation Dated: Job#: STA# MEASUREMENT ELEVATION REMARKS 1 0.00 63.31 BM/Prop. Corner 2 -0.25 63.06 Prop. Corner 3 1.90 65.21 4 2.65 65.96 5 4.90 68.21 Fin. Floor 6 2.65 65.96 7 2.25 65.56 8 3.05 66.36 High Point 9 2.55 65.86 10 1.10 64.41 11 0.85 64.16 12 0.80 64.11 Prop. Corner 13 0.55 63.86 Prop. Corner 14 0.80 64.11 15 0.60 63.91 16 2.90 66.21 17 2.30 65.61 High Point 18 19 20 21 22 Site: tb i North Summary of ooinlons: gIt is our opinion that the top of foundation and rades around the home are consistent with the above referenced grading plan or are a functionally adequate substitue. ❑ Rejected (2nd observation required) Corrective action: CTL I Thompson, Inc. 1 1103 Old Town lane, Cheyenne, WY 82009 JDD NM 225-01-25-01 DATE 05/M/14 SCALE 1'=20' DRAWN RS r4 Grown Tx ivieeriv>, llc. Structural E isuerin9 rj Insgec ions 524 Stover SL Phone: (970) 498 — 9537 Fort Collhm, Colorado 80524 CeO: (970) 691 — 4239 reyeaaf50mw.00m SITE PLAN LOT AREA = 3,400.00 SF FR; DEVELOPMENT LOT 11, BLOCK 9, 532 CAJETAN OLD TOWN NORTH SUB. No Text