Loading...
HomeMy WebLinkAboutLot Certifications - 11/17/2014 (4)Utilities i{ " electric . stormwater • wastewater . water E Y �� 700 Wood St. PO Box 580 Flirt Col lins Fort Collins, CO 80522 970.221.6700 970.221.6619619 fax . 970.224.6003 TDD utilitiesc@fcgov.com • Icgovcom/utilities CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: 03/26/15 Permit Application No. B1402670 Address: 432 Caietan Street Lot: 26 Block: 7 Subdivision: Old Town North Subdivision co ecedowtj c'A 117404 QJ�C.fOKi /',�N.rNat1 6N. �il'i�fM I,(Print) Wyatt M. Knutson , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): 03/26/15 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the lot/site are insubstantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. ® The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect sl consistent with the approved drainage plan. SEE By: and off the lot/site in a manner CO NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the IoVsIte, Including but not limited to drawings of the Iollsite showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. sweles, retaining walls, lot corners), written Informationtexplanation of discrepancies, and other information necessary to confirm the above certification to: Final Grade Assurance Observation: C T L f T H O M P S O N 1 L Per the client's request, a representative of CTL has visually observed and measured elevations of the grading aruond the home at the site referenced below. The following summarizes our observations and opinions at the time of our visit Client : FIR Development Site Address: 432 Cajetan Street Job#: WY00924.000 Lot: 26 Block: 7 Date: 3/26/2015 Contact: Kevin Dewlen Subdivision/filing: Old Town North Background Information: Referenced Grading Plan: Shear Engineering Corporation Dated: Job#: STA# MEASUREMENT ELEVATION REMARKS 1 0.00 62.35 BM/Prop. Corner 2 -0.05 62.30 Prop. Corner 3 0.35 62.70 4 3.05 65.40 5 5.35 67.70 Fin. Floor 6 3.28 65.63 7 2.60 64.95 8 2.55 64.90 High Point 9 3.05 65.40 10 2.10 64.45 11 1.55 63.90 12 1.60 63.95 Prop. Corner 13 1.40 63.75 Prop. Corner 14 2.05 64.40 15 1.10 63.45 Prop. Corner 16 3.15 65.50 17 0.75 63.10 18 19 20 21 22 Site: // 6La ,r /4'.. e fl` /.fq c nr3 North Summary of opinions: o It is our opinion that the top of foundation and grades around the home are consistent with the above referenced grading plan or are a functionally adequate substitue. o Rejected (2nd observation 'required) Corrective action: CTL I Thompson, Inc. 1 1103 Old Town Lane, Cheyenne, WY 82009 X lyq'r. ,, 3 , M1� RADIUS: 15.00' CHORD: 21.21' ry BRG: N17'48'46"W LOT 26 BLOCK 7 / n Ln / .'dry %asp JOB. 22 tom.I 225—01-27-01 Grown Zn meermi,llc DATE 05/30/14 Structural) ineerin9'� Ixfyu nf SCALE V-20' 524 Stover St. Phone: (970) 498 — 9537 DRAVIL Fort Collins, Colorado 80524 Cell: (970) 691 — 4239 RS reyessl50mmaom 7c� SITE PLAN LOT AREA = 3,761.11 SF FR DEVELOPMENT LOT 26, BLOCK 7, 432 CAJETAN OLD TOWN NORTH SUB. No Text