HomeMy WebLinkAboutLot Certifications - 11/17/2014 (4)Utilities
i{ "
electric . stormwater • wastewater . water
E Y ��
700 Wood St.
PO Box 580
Flirt
Col lins
Fort Collins, CO 80522
970.221.6700
970.221.6619619 fax . 970.224.6003 TDD
utilitiesc@fcgov.com • Icgovcom/utilities
CERTIFICATION OF LOT GRADING
Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e)
Date: 03/26/15
Permit Application No. B1402670
Address: 432 Caietan Street
Lot: 26 Block: 7
Subdivision: Old Town North Subdivision
co ecedowtj c'A 117404
QJ�C.fOKi /',�N.rNat1 6N. �il'i�fM
I,(Print) Wyatt M. Knutson , a Colorado registered professional engineer, verify that the
above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately
qualified professional under my direct supervision, and verify that construction of all stormwater facilities and
grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were
developed from a survey performed on (Date): 03/26/15 , accurately and truly depict the elevations and
drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one):
❑ The elevations and drainage patterns of the lot/site are insubstantial conformance with the City approved
drainage and grading plan for the property (information attached). SEE NOTE.
® The elevations and drainage patterns of the lot/site as measured are in general conformance with the City
approved drainage plan with exceptions (information attached). In my professional judgment the
elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the
specifically approved drainage plan, and will affect sl
consistent with the approved drainage plan. SEE
By:
and off the lot/site in a manner
CO
NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the IoVsIte, Including but not limited to drawings of the Iollsite showing the approved design and as -built surveyed
elevations of all structures, drainage and grading features (e.g. sweles, retaining walls, lot corners), written
Informationtexplanation of discrepancies, and other information necessary to confirm the above certification to:
Final Grade Assurance Observation: C T L f T H O M P S O N
1 L
Per the client's request, a representative of CTL has visually observed
and measured elevations of the grading aruond the home at the site referenced
below. The following summarizes our observations and opinions at the time of our visit
Client : FIR Development Site Address: 432 Cajetan Street
Job#: WY00924.000 Lot: 26 Block: 7
Date: 3/26/2015 Contact: Kevin Dewlen Subdivision/filing: Old Town North
Background Information:
Referenced Grading Plan: Shear Engineering Corporation
Dated: Job#:
STA#
MEASUREMENT
ELEVATION
REMARKS
1
0.00
62.35
BM/Prop. Corner
2
-0.05
62.30
Prop. Corner
3
0.35
62.70
4
3.05
65.40
5
5.35
67.70
Fin. Floor
6
3.28
65.63
7
2.60
64.95
8
2.55
64.90
High Point
9
3.05
65.40
10
2.10
64.45
11
1.55
63.90
12
1.60
63.95
Prop. Corner
13
1.40
63.75
Prop. Corner
14
2.05
64.40
15
1.10
63.45
Prop. Corner
16
3.15
65.50
17
0.75
63.10
18
19
20
21
22
Site: // 6La ,r /4'.. e fl`
/.fq c nr3
North
Summary of opinions:
o It is our opinion that the top of foundation and
grades around the home are consistent with the
above referenced grading plan or are a functionally
adequate substitue.
o Rejected (2nd observation 'required)
Corrective action:
CTL I Thompson, Inc. 1 1103 Old Town Lane, Cheyenne, WY 82009
X
lyq'r. ,, 3 , M1� RADIUS: 15.00'
CHORD: 21.21'
ry BRG: N17'48'46"W
LOT 26
BLOCK 7 / n
Ln / .'dry
%asp
JOB. 22 tom.I
225—01-27-01 Grown Zn meermi,llc
DATE
05/30/14 Structural) ineerin9'� Ixfyu nf
SCALE
V-20' 524 Stover St. Phone: (970) 498 — 9537
DRAVIL Fort Collins, Colorado 80524 Cell: (970) 691 — 4239
RS reyessl50mmaom
7c�
SITE PLAN
LOT AREA = 3,761.11 SF
FR DEVELOPMENT
LOT 26, BLOCK 7, 432 CAJETAN
OLD TOWN NORTH SUB.
No Text