Loading...
HomeMy WebLinkAboutLot Certifications - 06/29/2015 (8)City of Utilities electric• stormwater. wastewater• water F6rt Collins 700w°ods`. PO Box 580 Fort Collins, CO 80522 970.221.6700 970.221.6619 fax • 970.224.6003 TDD utilities@81cgov.com • kgov.corn/utilities CERTIFICATION OF LOT GRADING Date: 06/26/15 Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Permit Application No. B1412570 Address: 344 Pascal Street Lot: 20 Block: 8 Old Town North Subdivision OVI-T . --Z'14 .Sd /24'ZOI-Li I,(Print) Wyatt M. Knutson , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): 06/26/15 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. M The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are specifically approved drainage plan, and will affect stoi consistent with the approved drainage plan. SEE By: and equivalent to the Wff the lot/site in a manner CO NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the toilette, Including but not limited to drawings of the Iottslte showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written Information/explanation of discrepancies, and other information necessary to confirm the above certification to: Final Grade Assurance Observation: C T L I T H O M P S O N Per the client's request, a representative of CTL has visually observed and measured elevations of the grading aruond the home at the site referenced below. The following summarizes our observations and opinions at the time of our visit. Client: FIR Development Site Address : 344 Pascal Street Job#: WY00924.000 Lot: 20 Block: 8 Date: 6/26/2015 Contact: Kevin DeWen Subdivision filing: Old Town North Backaround Information: Referenced Grading Plan: Shear Engineering Corporation Dated: Job#: STA# MEASUREMENT ELEVATION REMARKS 1 0.00 61.66 BM/Prop. Corner 2 0.29 61.95 Prop. Corner 3 1.95 63.61 4 2.65 64.31 5 6.50 68.16 Fin. Floor 6 2.47 64.13 7 2.17 63.83 8 2.78 64.44 High Point 9 3.16 64.82 101 2.17 63.83 11 2.14 63.80 12 1.46 63.12 Prop. Comer 13 1.35 63.01 Prop. Corner 14 1.55 63.21 15 2.12 63.78 16 2.50 64.16 High Point 17 2.92 64.58 18 19 20 21 22 Site: ■■o■■■■ � ■mfo■mi ®■■■�i�ma�■ Wu �®OEM o eta■■■m ■ l■ua■■�■i■l■■_��m■■u■ ■■■m■■■■a■o �u ■■u■ oa■au■■mmNORM■o■■i■ ®m■■■®�mmnuuu■umii■ii of110111 ■ttt®■ ■■u ■tav■ultu■ m ■ ■!•� I■1�■/i f■OO■■■!■�! ■mmom■.■■..■■■■■■u■.. i■■■■ a North Summary of opinions: It is our opinion that the top of foundation and grades around the home are consistent with the above referenced grading plan or are a functionally adequate substitue. ❑ Rejected (2nd observation required) Corrective action: CTL I Thompson, Inc. 1 1103 Old Town Lane, Cheyenne, WY 82009 .AB N0. MP-01-36-01 12/04/14 SCALc 1'=20' DRAWN RS RADIUS: CHORD: BRG: N70' Grvx�t�ngtineerivi�,tonltc. Strsrttxral E tixeerixq aj Txs�rtc s 524 Stow St. Phone. (970) 498 — 9537 Fort Collins. Colorado 80524 Cell: (970) 601 — 4239 reyeeef50man.eom 3,0/ 21 SITE PLAN LOT AREA = 3,628.62 SF FR DEVELOPMENT LOT 20, BLOCK 8 344 PASCAL OLD TOWN NORTH SUB. No Text