CERTIFICATION OF LOT GRADING
Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) 4 SOOA6c%ra .s '�r CO on ¢z4/2ocs
Date: 05/19/15 �riow ri��osrc 4�9�2otS
Permit Application No. B1412044 �►l,�
Address: 350 Pascal Street
Lot: 19
Subdivision: Old Town North Subdivision
I,(print) Wyatt M. Knutson a Colorado registered professional engineer, verify that "the
above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately
qualified professional under my direct supervision, and verify that construction of all stormwater facilities and
grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were
developed from a survey performed on (Date): 05/19/15 accurately and truly depict the elevations and
drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one):
0 The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved
drainage and grading plan for the property (information attached). SEE NOTE.
M The elevations and drainage patterns of the lot/site as measured are in general conformance with the City
approved drainage plan with exceptions (information attached). In my professional judgment the
elevations and grading of the lottsite as constructed are functio adequate and equivalent to the
specifically approved drainage plan, and will affect sto �t1jQDa� g and off the lot/site in a manner
consistent with the approved drainage plan. SE 0. KN
By:
t. r
si ure, PE stadtjJ
��no �mmoth I naton. CO
NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the Wells, including but not limited to drawings of the lottaite showing the approved design and as -built surveyed
elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written
Information/explanation of discrepancies, and other Information necessary to confirm the above certfficatlon to:
Final Grade Assurance Observation: C T L l T H O M P S O N
loll
Per the client's request, a representative of CTL has visually observed
and measured elevations of the gred'ug aruond the home at the site referenced
below: The followi '- -."" -- -b - - __ _.
ng summarizes our observiationsand--"nions'iif tFio-time bf our visit. - -
Client: FR Development Site Address: 350 Pascal Street
Job#: WY00924.000 Lot: 19 Block: 8
Date: W19/2015 Contact: Kevin Dewlen Subdivisiontfiling: Old Town North
Background Information:
Referenced Grading Plan: Shear Engineering Corporation
Dated: Job*
STA#
MEASUREMENT
ELEVATION
REMARKS
1
0.00
62.04
BM/Prop. Corner
2
-0.21
61.83
Prop. Corner
3
1.75
63.79
4
2.22
64.26
5
4.88
66.92
Fin. Floor
6
2.72
64.76
7
2.08
64.12
8
2.74
64.78
High Point
9
3.27
65.31
10
1.15
63.19
ill
1.61
63.65
12
0.97
63.01
Prop. Comer
13
1.07
63.11
Prop. Comer
14
1.51
63.55
15
1.13
63.17
16
2.72
64.76
17
2.34
64.38
High Point
18
19
20
21
22
Site:
North
§Mmmary of opinions:
It is our opinion that the top of foundation and
grades around the home are consistent with the
above referenced grading plan or are a functionally
adequate substitue.
o Rejected (2nd observation required)
Corrective action:
CTL I Thompson, Inc. 1 1103 Old Town Lane, Cheyenne, WY 82009
� � �•Ns7s849, pt
yl �NN
= 7/
01).
e �Hro
A
NN
4f / LOT 19 =
BLOCK 8 y1 00
I �
`a016
Ya1'� E;l
Rgseq< 3TR
�efT
SITE PLAN
LOT AREA = 3,227.53 SF
"O. 225-01-37-01 Crown Engineering, I FcR DEVELOPMENT
DATE
11/14/14 Structural Engineering & Inspections LOT 19, BLOCK 8, 350 PASCAL
SCALE20' 524 stover St. Phone: (970) 498 - 9537 OLD TOWN NORTH SUB.
DRAVte Fart Wine. Colorado 80524 Cell: (970) 691 — 4239
RS reyouffiGmsn.em