Loading...
HomeMy WebLinkAboutLot Certifications - 05/22/2015 (10)Utilities City electric. slonnwater. wastewater. water of Fort 700 Wood St. Boz 580 Collins Fo rl Collins, CO 80522 970.221.6700' 970.221.6619619 fax • 970.224.61103 TDD utilities@fcgov.com . kgov.cotWutilities CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2:2 (e) Date: 05/19/15 iJF7 Permit Application No. B1405044 (p rcltmse& Address: 369 Pascal Street Lot: 19 Block: 5 Subdivision: Old Town North Subdivision I,(Print) Wyatt M. Knutson a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): 05119/15 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. ® The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormwgierQ�riK&&Son and off the lot/site in a manner consistent with the approved drainage plan. SE °• ° h By: Co NOTE: A COMPLETE certification must be submitted at least two weeks prlm to a request for a Certificate of Occupancy for the IoUsite, Including but not limited to drawings of the Iot/slte showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written information/explanation of discrepancies, and other Information necessary to confirm the above certification to: Final Grade Assurance Observation: IF C T L I T H O M P S O N Per the client's request, a representative of CTL has visually observed and measured elevations of the grading aruond the home at the site referenced below. The following summarizes our observations and opinions at the time of our visit. Client: FIR Development Site Address : 369 Pascal Street Job#: WY00924.000 Lot: 19 Block: 5 Date: 5/19/2015 Contact: Kevin Dewlen Subdivisionffiling: Old Town North Background Information: Referenced Grading Plan: VFLA Dated: 9/19/2014 Job#: 2014-14 STA# MEASUREMENT ELEVATION REMARKS 1 0.00 61.64 BM/Prop. Corner 2 0.15 61.79 Prop. Corner 3 4.29 65.93 4 4.90 66.54 5 6.89 68.531 Fin. Floor 6 5.64 67.28 7 4.62 66.26 8 5.87 67.51 9 5.19 66.83 Hi h Point 10 1.54 63.18 11 1.32 62.96 12 0.47 62.11 Prop. Corner 13 0.50 62.14 1 Prop. Corner 14 1.46 63.10 151 1.24 62.88 161 6.35 67.99 171 5.84 67.48 High Point 18 19 20 21 22 Site: North �,urnmary of opinions: It is our opinion that the top of foundation and g ades around the home are consistent with the above referenced grading plan or are a functionally adequate substitue. ❑ Rejected (2nd observation required) Corrective action: CTL I Thompson, tnc. 1 1103 Old Town Lane, Cheyenne, WY 82009 No Text No Text o \` }��� q\ Q no� • . �• . ` § " | ) E| ! • § 7