CERTIFICATION OF LOT GRADING
Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e)
Date: 05/19/15
Permit Application No. B1—� (y
Address: 363 Pascal Street
Lot: 1$ Block: 5
Subdivision: Old Town North Subdivision
Co C�4. <b y%sil2o�� '\
I,(Print) Wyatt M. Knutson a Colorado registered professional engineer, verify that the
above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately
qualified professional under my direct supervision, and verify that construction of all stormwater facilities and
grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were
developed from a survey performed on (Date): 05/19/15 , accurately and truly depict the elevations and
drainage patterns as they existed on the date of the survey. Based on this information, I, certify that (check one):
❑ The elevations and drainage patterns of the lot/site are insubstantial conformance with the City approved
drainage and grading plan for the property (information attached). SEE NOTE.
® The elevations and drainage patterns of the lot/site as measured are in general conformance with the City
approved drainage plan with exceptions (information attached). In my professional judgment the
elevations and grading of the lo/site as constructed are function
specifically approved drainage plan, and will affect stormwaiegi
consistent with the approved drainage plan. SEE
By:
adequate and equivalent to the
PE
off the lot/site in a manner
CO
NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the lot/site, Including but not limited to drawings of the Iottslte showing the approved design and as -built surveyed
elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written
Information/explanation of discrepancies, and other Information necessary to confirm the above certification to:
Final Grade Assurance Observation: C T L I T H O M P S O N
Per the client's request, a representative of CTL has visually observed
and measured elevations of the grading amond the home at the site referenced
below. The following summarizes our observations and opinions at the time of our visit.
Client: FIR Development Site Address : 363 Pascal Street
Job#: WY00924.000 Lot: 18 Block: 5
Date: 5/1912015 Contact: Kevin Dewlen Subdivision/filing: Old Town North
Background Information:
Referenced Grading Plan: VFLA
Dated: 9/19/2014 Job#: 2014-14
STA#
MEASUREMENT
ELEVATION
REMARKS
1
0.00
61.64
BM/Prop. Corner
2
0.56
62.20
Prop. Corner
3
2.04
63.68
4
3.06
64.70
5
0.76
62.40
Fin. Floor Slab
6
12.19
73.83
Fin. Floor Main
7
5.16
66.80
8
4.62
66.26
9
5.19
66.83
High Point
10
5.86
67.50
11
2.48
64.12
12
1.32
62.96
13
0.47
62.11
Prop. Corner
14
1.08
62.72
Prop. Corner
15
1.47
63.11
16
1.42
63.06
17
5.50
67.14
18
5.29
66.93
High Point
19
20
21
22
Site:
North
Summary of opinions:
It is our opinion that the top of foundation and
grades around the home are consistent with the
above referenced grading plan or are a functionally
adequate substitue.
❑ Rejected (2nd observation required)
Corrective action:
CTL [ Thompson, Inc. I 1103 Old Town Lane, Cheyenne, WY 82009