HomeMy WebLinkAboutSite Certifications - 07/20/2005NORTHERN ENGINEERING SERVICES, INC. July 19, 2005 Jay Barber Fort Collins Stormwater Utility 700 Wood St. Ft.Collins, CO 80522 RE: —Raising Cane's Drainage Certification (Certification of Outstanding Items) ,,Project Number: 03-113.15 CER Dear Jay: STORMWAT E6R RECEIVED JUL. 2 0 2005 We have completed our review of the outstanding items for the "Raising Cane's" project, as noted in our previous Partial Drainage Certification dated March 16, 2005. The project engineer conducted a site visit on July 19, 2005 to verify the following: • Completion of the water quality pond outlet. • Completion of the two concrete flumes conveying drainage down the west side of the water quality pond. • Completion of the pan at the southeast comer of the site, which was an addendum to the approved plans. Based on personal inspection, we believe the above items have been substantially completed. Based on this, and on the information regarding all other major drainage improvements discussed in our previous certification letter, we believe the entire site is now in substantial compliance with the design intent of the approved construction drawings. If you require additional information or analysis regarding this project please contact me at 221-4158 ext.106. Sincerely, NORTHERN ENGINEERING SERVICES, INC. Aaron Cvar, P.E. Senior Engineer cc: Brad Sanders, Raising Cane's Chicken Fingers Pi -P 9I,2-3/65 420 SOUTH HOWES, SUITE 202 / FORT COLLINS, COLORADO 80521 / 970.221:4158 / FAX 970.221.4159 NORTHERN ENGINEERING NESERVICESo INC. March 16, 2005 Jay Barber Fort Collins Stormwater Utility 700 Wood St. Ft.Collins, CO 80522 RE: Raising Cane's Partial Drainage Certification Project Number: 03-113.15 CER Dear Jay: STORMWATER RECEIVED MAR 16 2005 We have completed our review of the as -constructed major drainage improvements for the above referenced project as it relates to the approved final construction plan design. This certification is intended to verify compliance of the constructed major drainage improvements for the approved construction plans entitled "Raising Cane's", dated August 2004. Field surveys of the site were conducted by RJL Surveyors in March of 2005 and have been used to verify general conformance to the Plans. The project engineer conducted a site visit on March 15, 2005 to verify grading and major drainage improvements. Based on the survey data provided by RJL and personal site inspection, we believe that all major drainage improvements have been constructed in general compliance with the design, with the following exceptions: The water quality pond outlet is not completed to date. The two concrete flumes conveying drainage down the west side of the water quality pond are not completed to date. The pan at the southeast comer of the site, which was an addendum to the approved plans, has not been completed to date. The volume for the water quality pond was calculated from the topography provided by RJL Surveyors. The design volume for this pond was 0.04 acre-feet. The as -built pond provides a water quality capture volume of 0.05 acre-feet (see attached calculations). Thus, we conclude that the water quality pond will perform adequately with the design intent: We will follow up with an additional letter of certification for the above items that have not been completed to date. Apart from these items, there are minor inconsistencies throughout the site; however, the performance of the drainage design, in my opinion, will not be hindered. Apart from the above items not yet completed, to the best of my knowledge the major drainage improvements for the Raising Cane's site are constructed in substantial compliance with the design intent of the approved construction drawings. If you require additional information or analysis regarding this project please contact me at 2214158 ext.106. Sincerely, NORTHE ?0G ENG14 INEERING SERVICES, INC. �pS/s, O.O Aaron Cvar, P.E. 3627 . Senior Engineer :• •3 ` cc: Brad Sanders, Raising Cane's Chicken Fingers ys, At 420 SOUTH HOWES, SUITE 202 / FORT COLLINS, COLORADO 80521 / 970.221.4158 / FAX 970.221.4159 3,j� lvs : I tmp#i.txt #Units=Elevation,ft,Area,ac,volume,acft,volume,acft # Elev Area conic Vol cumml conic # ft ac acft acft g'o 02.75 0.05 0.01 0.05 2.50 0.04 0.01 0.04 2.25 0.04 0.01 0.03 2.00 0.03 0.01 0.02 %1.75 0.02 0.01 0.01 1.50 0.02 0.00 0.01 1.25 0.01 0.00 0.00 1.00 0.01` 0.00 0.00 0.75 0.00 0.00 0.00 50a 0.50 0.00 0.00 0.00 50�.3 � � i ►� J Ar'Tr �A nitE'S Vo L %J M r,- a i Dt�S STORMWATER RECEIVED MAR 16 2005 Page 1