Loading...
HomeMy WebLinkAboutSite Certifications - 07/18/2008July 2, 2008 WE Mr. Jay Barber J•R ENGINEERING City of Fort Collins A Westrian company Storm Water Utility 700 Wood Street Fort Collins, CO 80521 Re: SITE CERTIFICATION FOR THE SHORES OFFICE PARK P.U.D., A PORTION OF LOT 1 AKA BUILDING ENVELOPE 4 JR Project 39539.00 �. i/rf Dear Mr. Barber, We are submitting for your review and approval an overall site certification and as constructed survey of the grading and drainage facilities for the above referenced project based on a record survey conducted by JR Engineering in June 2008. The following is a summary of our findings: The as -built grading elevations appear to be in general conformance with the approved site grading plans except for the areas near the water quality Swale. As -built spot elevations in this area indicate the Swale is flatter than proposed and in some areas the slope is slightly reversed. However, the water quality Swale was intended to be fairly flat with layers of peat mixed sand and gravel beneath the surface to enhance infiltration, and thus, the inconsistencies with the Swale grading are not expected to have a negative impact on the site drainage. To the best of our knowledge the grass Swale layers were installed per plan in the appropriate areas. In conclusion, based on our record survey, the drainage facilities for The Shores have been constructed in general conformance to the approved plans except for the aforementioned inconsistencies in the grass swale area. I find that the storm system as built, should operate as designed in the approved final drainage report. If you have any questions or comments, please contact me at 970.491.9888. Attached are the following supporting documents: • The standard "Drainage Certification Form" used by the City of Fort Collins that provides a list of the various drainage items checked. • A grading exhibit showing the proposed spot elevations vs. the as -built elevations for the site. 2620 Fast Prospect Road, Suite 190, Fort Collins, CO 80525 970-491-9888 • Fax: 970-491-9984 • w Jrengineering.corn Mr. Jay Barber, July 2008 Page 2 of 2 Respectfully submitted, Prepared by: Justin Fecteau Design Engineer Reviewed By Timothy Halopoff Client Manager ���'pN J 7-2-0� Q .•• AF S/ONALENG\� X:\3950000.a11\3953900\Word\Letters\3953900 SITE CERT.doc DRAINAGE CERTIFICATION FORM Please fill out all applicable items in this certification form for single family, multi -family and commercial properties. Write "OK" for items checked or actual number checked in field. Use "N/An for items that are not applicable to the property that is being certified. A. Drainage facilities certification 1. Pond Certification- pjopo&jos WgRg DR4,p'gwD 6oz-1d TNSS P*d7t6s -volume verificationA14 a.topographic records and volume b.cross-sections and spot elevations -positive fall to pan NA -side slopes n/A -invert elevationn/A -spillway elevationn%q -placement and size of riprap NA -side slopes VA? _grading A/A -orifice plate installation and size_A/Q -compaction of berm VA -structural integrity of pondA(A 2. Swales ,A miNOR ,fW,99 014 TfIf &Vftl ANP EA6; Srxv of iY AROPERtY ' -location (are they within easement)NA -dimensions and cross-section .verification NA -longitudinal slopes and side slopes oK -spot elevations O K -permanent erosion control measures (drop structures, riprap, etc....) p/l -tie-in to pipes, pans, curbs, etc.... U/<" -weir size (elevations, size, opening, etc.)^/q -available freeboard AUK -landscaping infringement on swales NA 3. Pipes AJjA1A- paopa wp -size and type A14 -slopes (as -built and comparison to minimum 0.4% , slope) AW -pipe capacity calculations if slopes are significantly altered A14 -invert elevations NA -installation and backfill materialAIA -cover AIA -encasement and clearance from other utility lines close by.IVA -joints A/A 4. Concrete Pan Channels A/Mer PADPO3 R -size IVA -slope /J,q -super elevation AN -cross .section NA -thickness AJA -elevations 014 5. Inlets /VO/JE - PROP05g'� . -size and type Alfi -size of opening (or name of standard used) NA -grate elevation NA -invert elevation /JA -box size Alp 6. Cross pans AINi, PRoposco -size AM -type AIA -grade AM -elevation AIA -cross-sectional depth A/.4 -tie-in to curb and gutter N9 7. Culverts A/swr pAoppAgo -size NA -type n/A -invert elevationA14 -headwalls NR 8. Underdrains MONO pa61045C0 .size A/# -type AM -cover -A./i% -backfillAJ4 -geotextiles M'7 -cleanouts AAA 9. Curb cuts -size -tie in to swale, pipe, etc... c/'4� B. Certification of Grade Elevations Adjacent to Drainage Facilities: -minimum opening elevations OAS -top of foundation elevations O/G -comparison to 100 year WSEL's (Freeboard requirements and floodplain issues) C. Certification of Erosion Control Measures: 1. Permanent Measures: -Permanent vegetation (6" bare spots and weeds under control)pK -riprap ^/A -riprap bedding./IA -drop sections N9 -sediment basins/water quality ponds.iVK -netting mats/blankets/*jA -mulching 2. Temporary Measures: -mulching ,vq -inlet filter installation'A/A -check bale dams NA' -seeding and temporary vegetation O/f -silt fence, 0/C D. Site Cleanup After Construction -construction clean up -smoothing of ruts -reseeding E. Statement of Compliance This certification is signed and stamped and by signing this form the engineer(s) attests that they have inspected u the site and to the best of their knowledge the as -built conditions of the drainage facilities are described in the above form and in the redlined plans enclosed. Failure to properly disclose all known information could result in the rejection of this certification and prevent the release of any Stormwater Utility holds on Building Permits and/or Certificates of Occupancy. F. Signature and Stamp by a Colorado Registered Professional Engineer.