Loading...
HomeMy WebLinkAboutLot Certifications - 04/26/2006Utilities electric • stormwater • wastewater • water City of Fort Collins CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: pp --AL 14 , 7^X=b! Permit Application No. Address: C=>0-7jj Lot: / Block: J7 Subdivision: M-JVM-r.— 1-10L;e:r— I,(Print)a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or someone under my direct supervision, and verify construction of all stormwater facilities and grading is complete, and the elevations and drainage 'patterns shown on the attached drawing(s) which were developed from a survey performed on (Date) ..A.P2a1_ 1-2 0 Zccj�-w , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot as constructed is functionally adequate and will allow for stormwater drainage consistent with the approved drainage plan. SEE NOTE. (signature, PE stam ) (address of signing party) NOTE: A COMPLETE certification must be submitted, including but not limited to drawings of the lot/site showing the approved design and as - built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written infomrettonlexplanation of discrepancies, etc. to: Fort Collins Utilities (970) 2214700 700 Wood Street Fort Collins, CO 80821 At Least Two Weeks Prior To Requesting A Certificate 0f Occupancy For The Property 06 n� NORTHERN ENGINEERING April 20, 2006 Mr. Jay Barber Stormwater Utilities 700 Wood Street Fort Collins, Colorado RE: Myrtle Court Townhomes Building "D" Jay, ADDRESS: PHONE:970.221.4158 WEBSITE: 200 S. College Ave. Suite 100 Fort Collins, CC 80524 FAX: 970.221.4159 www.northernengineering.com STORMWATER RECEIVED APR 2'0 2006 This is in regards to the Myrtle Court Townhomes, and in particular to Building "D". This project is being built by Steve Spanjer. The original plans for this project were done by Ayres and Associates. I have attached a sketch of the site, with as constructed elevations shown. During construction, we added a small shallow protective Swale along the south side of the building, with culverts and sidewalk chases at the sidewalks. Since Northern Engineering conducted the onsite survey, they have made some modifications, particularly as they relate to the window wells, and the minimum opening elevations. They have installed a small timber tie wall around each of the openings along the south side, given the relative lack of grade from the window well threshold to the protective swale (these are not reflected on our attached sketch). Anyway, please call if you have any questions, or would like to meet onsite to take a look at the final grading. Thanks for your time. 1, Roger A Curtiss, P.E. Project Engineer — Northern Engineering cc: Steve Spanjer — Spanjer Homes IMPROVEMENT LOCATION CERTIFICATE FOR MYRTLE COURT CONDOMIUMS LEGAL DESCRIPTION: BUILDING 'D' AT MYRTLE COURT, CITY OF FORT COLLINS, LARIMER COUNTY, STATE OF COLORADO, ADRESS, 607 COWAN STREET MYRTLE STREET 190.09, N89054' 11 "W tl u I N 1 A FUTURE i BUILDING " A " 11 e ❑ 1 p I 1 1 1 I 1 P ; 1 1 LLI 1 G p 1 FUTURE J o BUILDING " B " I o 0 Z 1 I 1 0 II tl tl 1 1 1 w 1 1 Q u w u w 04 1 FUTURE U) Jys �01 BUILDING o3" G1� Z 61 /07 -l&I' ail �' �i-I G1 I9 N 1 , 5L.a W vlp —3 /off I • 1.� .� � 00'. `' � � :, �-`` dZ � � �� 7Ll�•� � Y d . a . . • °. `. � Z{'.EM�fiENC1��SS { �Q. �a 3� � .� '. � V EASEMENT EASII A. ( �1�I •• 1�7. _ EW_ �• a * _ _ a ��'y+ d ` I o { ` a zo.D 1sa L1 i Story Wood and Stone Siding ` M 1 2. . w/ Basement •. �.�wy v 1 t— UNIT2 1. UNIT 1 C I. 1 (J q1 C _p 1 ILS 40 B P1PC 18.5 �O PIPC G, 4�� (,ig' - %14= .. �' G7SU QIEe s G1-- 1 Irv; RRIQ GL'�$ — GLa, 7 — 2L �zIDA y 190.09'—S89°54'11'E ' —f u u ELLV4TID05, REGORPJCT] I 1 30 15 0 30 bQ 4-12-C(G n ( IN FEET ) 1 " = 30 FT. I HEREBY CERTIFY THAT THIS IMPROVEMENT LOCATION CERTIFICATE WAS PREPARED FOR SPANJER HOMES AND THAT IT IS NOT A LAND SURVEY PLAT OR IMPROVEMENT SURVEY PLAT, AND THAT IT IS NOT TO BE RELIED UPON FOR THE ESTABLISHMENT OF FENCE, BUILDING. OR OTHER FUTURE IMPROVEMENT LINES. 1 FURTHER CERTIFY THAT IMPROVEMENTS ON THE ABOVE DESCRIBED PARCEL ON THIS DATE: APRIL 11, 2006 EXCEPT UTILITY CONNECTIONS, ARE ENTIRELY WITHIN THE BOUNDARIES OF THE PARCEL, EXCEPT AS SHOWN, THAT THERE ARE NO ENCROACHMENTS UPON THE DESCRIBED PREMISES BY IMPROVEMENTS ON ANY ADJOINING PREMISES, EXCEPT AS INDICATED AND THAT THERE IS NO APPARENT EVIDENCE OR SIGN OF ANY EASEMENT CROSSING OR BURDENING ANY PART OF SAID PARCEL, EXCEPT AS NOTED. NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS IMPROVEMENT LOCATION CERTIFICATE WITHIN THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT, MAY ANY ACTION BASED UPON ANY DEFECT IN THIS IMPROVEMENT LOCATION CERTIFICATE BE COMMENCED MORE THAN TEN YEARS AFTER THE DATE OF THE CERTIFICATION SHOWN HEREON. SPANJER HOMES NORTHERN ENGINEERING 2w S:&X Ate".,S lw F E: 9'lO.221.41W FAY: 9'N.221A1S9 F"1 Wim C9brY0o 0XV1 wr..mlMnpM°MKmm OpviD ' ST E, GERALD D. GIWLAND COLORADO P.L.S. NO. 14-823 MYRTLE COURT BUILDING 'D' No. REVISION I SY DATE �uu L- EAST MUIHERRY STREET EAST MYRTLE STREET ru F � � b y b EAST LAUREL STREET KEY MAP NOT TO SCALE PROJECT#: 123-003 DRAWN BY: WTR DATE: 041l 1/05