HomeMy WebLinkAboutLot Certifications - 07/24/2006_ Jul 20 06 05:30p
p.2
Utilities
electric a storr.:ieater -a v.astew•ater o ivatez
Ar-
Qity of Fort COM-as CERTIFICATION OF LOT GRADING
Pursuant to City Code § 26-544 and
j City Land Use Code § 3.2.2 (e)
Date: V UL3. 20 ,1W6
Permit Application No.
Address: ��0 3 �'OW N opal R
Lot a(P Block t lA
Subdivision: 4%ACTl FIELF, M 2,MD _:FAuN4
STORMWATER
RECEIVED
JUL 2 0 2006
(, (Print) V -20- i L a Colorado registered processional engineer,
have personally inspect the above referenced property in. the City of Fort Collins, Colorado, and verify
that. construction of all stonnwater facilities and grading there is complete, and that the elevations and
drainage atterrls shown on the attached drawing(s) which were developed from a survey performed on.
(Date) accurately and truly depict the elevations and drainage patterns as
they existed on the dare of the survey. Based on this information, I certify that (check one):
The elevations and drainage patterns of the lot are in substantial conformance with the City
approved drainage and grading plan or revised grading plan for the property (information
attached). SEE NOTE
❑ The elevations and drainage patterns of the lot as measured are in general conformance with the
City approved drainage plan or revised grading plan with exceptions (nformation attached). In
myprofessional judgment the elevations and grading of the lot as constructed is functionally.
adequate and wiA allow for stormwater drainage consistent with the approved drainage plan.
SEE NOTE.--
co/ �
.. ,
BY:
:,, �-., -�• :r ;� <�(&ature'4P9=2
Ti
1&5
?.id 59W L.oyelar�a(Co �0537
.
(address of signing party)
NOTE.
A COMPLETE certification must be submNtrd, 6xhaflng but not rmribd to drawaags of the lotfsrb showing the appeored design or
revised design and as -built surveyed elavatiora of all structsues•and drainage and grading features (e g. swales, retaining walls, lot
comers). written InformadonkViarWion of discrepancies, etc. to:
Fort Collins utilities (970) 221-FM
700 wood street
Fort Collins, CO 80521
At Least TWO weei6 Prior To ftWnsSng A CartiFcabe Of occupancy For The Property
X-t,,& -11aq14,C
Jul 20 06 05:30p
p.3
O
2
Ar
a�
r
�ras4
x� o2
LOT 26
1105 TOWN CENTER DR
HEARTHFIRE PUD
SECOND FILING
FT. COLLINS, CO
STORMWATER
RECEIVED
JUL 2,0 2006
40 0 40
SCALE 1"=40'
x® INDICATES GROUND SHOT
PER CDS ENGINEERING
I, Michael J DeDecker, a duly registered Professional Land Surveyor In the State of Colorado do hereby state that
the elevations shown on this Grading Certificate are the direct result of field shots taken July 19, 2006 by me or
by personnel under my supervision, and are to represent field conditions on the date of the survey.
Michael J DeDecker PLS 20676
For and on behalf of
MS Engineering Corp.
NOTICE: Aeoordinq to Colorado law, you MUST commence any Iepal
aCMon boned an any defect in this survey within THREE
Years after you That discovered such defect In no
event may any action tweed upon any defect In this
survey be Commenced more than TEN years from the
date of the certification shown hereon.
SCALE: 1• - 40 , Engineering JOHN PROXCT Na 05-4035
DATE: 7-20-06 ® Corporation WALZ f>RMINo Na 4035 L26
RELD BOOK: N/A 165 2nd ST SW REVISION Na
LOVELAND, COLORADO 80538 ENTERPRISES
DRAWN: TMO CHECKED: MJD 970) _667-8010 SHEET 1 OF 1
Jul 20 06 05:30p
p.4
DRAINAGE CERTIFICATION FORM
Please fill out all applicable items in this certification
form for single family, multi -family and commercial
properties.
Write "OK" for items checked or actual number checked in
field.
Use "N/An for items that are not applicable to the property
that is being certified. STORMWATER
RECEIVED
A_ Draiaage facilities certification
1. Pond Certification
-volume verification
a.topographic records and volume
b.cr6ss-sections and spot elevations
-positive fall to pan
-side slopes
-invert elevation .
-spillway elevation
-placement and size of riprap
-side slopes
_grading
-orifice plate installation and size_
-compaction of berm
-structural integrity of pond
t4A 2. swales
-location (are they within easement).
-dimensions and cross-section verification
-longitudinal slopes and side slopes
-spot elevations
JUL 2`0 2006
Jul 20 06 05:30p p.5
-permanent erosion control measures (drop structures,
riprap, etc....)
-tie-in to pipes, pans, curbs, etc....
-weir size (elevations, size, opening, etc.) S RECEIVED R
-available freeboard
JUL 2 0 2006
-landscaping infringement on swales
3. Pipes
-size and type
-slopes (as -built and comparison to minimum 0.4%
slope)
-pipe capacity calculations if slopes are
significantly altered
7'$$ -invert elevations .
-installation and backfill material
-cover
-encasement and clearance from other utility lines
close by
-joints
4. Concrete Pan Channels
-size
-slope
-super elevation
-cross .section
-thickness
-elevations
gh 5. Inlets
-size and type
Jul 20 06 05:31p
p.6
-size of opening (or name of standard used)
-grate elevation
-invert elevation
-box size
t,*6. cross pans
-size
-type
-grade
-elevation
-cross-sectional depth
-tie-in to curb and gutter
t* 7. Culverts
-size
-type
-invert elevation
.-headwalls
t4p, 8. onderdrains
-size
-type
-cover
backfill
-geotextiles
-cleanouts
9. Curb cuts
-size
STORMWATER
RECEIVE®
JUL 2.0 2006
-tie in to Swale, pipe, etc...
B. Certification of Grade Elevations Adjacent to Drainage
Facilities:
Jul 20 06 05:31p
p.7
STORMWATER
RECEIVED
5D 83,( -minimum opening elevations
JUL 2-0 2006
�gr:).i -top of foundation elevations
-71,4:j -comparison to 100 year WSEL's (Freeboard
requirements and floodplain issues)
C. Certification of Erosion Control Measures:
Ak. Permanent Measures:
-Permanent vegetation (6" bare spots and weeds under
control)
-riprap
-riprap bedding
-drop sections
-sediment basins/water quality ponds
-netting mats/blankets
-mulching
f4f-2. Temporary Measures:
-mulching
-inlet filter installation
-check bale dams
-seeding and temporary vegetation
-silt fence
D. Site Cleanup After Construction
.construction clean up
smoothing of ruts
-reseeding
,i s. Statement of Compliance
This certification is signed and stamped and by signing
this form the engineer(s) attests that they have inspected
Jul 20 06 05:31p p,g
the site and to the best of their knowledge the as -built
conditions of the drainage facilities are as described in
the above form and in the redlined plans enclosed.
Failure to properly disclose all known information could
result in the rejection of this certification and prevent
the release of any Stormwater Utility holds on Building
Permits and/or Certificates.of Occupancy.
v4,_ Signature and Stamp by a Colorado Registered
Professional Engineer.
.STORMWATE'R
RECEIVED
JUL 2`0 2006
Jul 20 06 05:31
STORMWATER
RECEIVED
JUL 2'0 2006