Loading...
HomeMy WebLinkAboutLot Certifications - 07/24/2006_ Jul 20 06 05:30p p.2 Utilities electric a storr.:ieater -a v.astew•ater o ivatez Ar- Qity of Fort COM-as CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and j City Land Use Code § 3.2.2 (e) Date: V UL3. 20 ,1W6 Permit Application No. Address: ��0 3 �'OW N opal R Lot a(P Block t lA Subdivision: 4%ACTl FIELF, M 2,MD _:FAuN4 STORMWATER RECEIVED JUL 2 0 2006 (, (Print) V -20- i L a Colorado registered processional engineer, have personally inspect the above referenced property in. the City of Fort Collins, Colorado, and verify that. construction of all stonnwater facilities and grading there is complete, and that the elevations and drainage atterrls shown on the attached drawing(s) which were developed from a survey performed on. (Date) accurately and truly depict the elevations and drainage patterns as they existed on the dare of the survey. Based on this information, I certify that (check one): The elevations and drainage patterns of the lot are in substantial conformance with the City approved drainage and grading plan or revised grading plan for the property (information attached). SEE NOTE ❑ The elevations and drainage patterns of the lot as measured are in general conformance with the City approved drainage plan or revised grading plan with exceptions (nformation attached). In myprofessional judgment the elevations and grading of the lot as constructed is functionally. adequate and wiA allow for stormwater drainage consistent with the approved drainage plan. SEE NOTE.-- co/ � .. , BY: :,, �-., -�• :r ;� <�(&ature'4P9=2 Ti 1&5 ?.id 59W L.oyelar�a(Co �0537 . (address of signing party) NOTE. A COMPLETE certification must be submNtrd, 6xhaflng but not rmribd to drawaags of the lotfsrb showing the appeored design or revised design and as -built surveyed elavatiora of all structsues•and drainage and grading features (e g. swales, retaining walls, lot comers). written InformadonkViarWion of discrepancies, etc. to: Fort Collins utilities (970) 221-FM 700 wood street Fort Collins, CO 80521 At Least TWO weei6 Prior To ftWnsSng A CartiFcabe Of occupancy For The Property X-t,,& -11aq14,C Jul 20 06 05:30p p.3 O 2 Ar a� r �ras4 x� o2 LOT 26 1105 TOWN CENTER DR HEARTHFIRE PUD SECOND FILING FT. COLLINS, CO STORMWATER RECEIVED JUL 2,0 2006 40 0 40 SCALE 1"=40' x® INDICATES GROUND SHOT PER CDS ENGINEERING I, Michael J DeDecker, a duly registered Professional Land Surveyor In the State of Colorado do hereby state that the elevations shown on this Grading Certificate are the direct result of field shots taken July 19, 2006 by me or by personnel under my supervision, and are to represent field conditions on the date of the survey. Michael J DeDecker PLS 20676 For and on behalf of MS Engineering Corp. NOTICE: Aeoordinq to Colorado law, you MUST commence any Iepal aCMon boned an any defect in this survey within THREE Years after you That discovered such defect In no event may any action tweed upon any defect In this survey be Commenced more than TEN years from the date of the certification shown hereon. SCALE: 1• - 40 , Engineering JOHN PROXCT Na 05-4035 DATE: 7-20-06 ® Corporation WALZ f>RMINo Na 4035 L26 RELD BOOK: N/A 165 2nd ST SW REVISION Na LOVELAND, COLORADO 80538 ENTERPRISES DRAWN: TMO CHECKED: MJD 970) _667-8010 SHEET 1 OF 1 Jul 20 06 05:30p p.4 DRAINAGE CERTIFICATION FORM Please fill out all applicable items in this certification form for single family, multi -family and commercial properties. Write "OK" for items checked or actual number checked in field. Use "N/An for items that are not applicable to the property that is being certified. STORMWATER RECEIVED A_ Draiaage facilities certification 1. Pond Certification -volume verification a.topographic records and volume b.cr6ss-sections and spot elevations -positive fall to pan -side slopes -invert elevation . -spillway elevation -placement and size of riprap -side slopes _grading -orifice plate installation and size_ -compaction of berm -structural integrity of pond t4A 2. swales -location (are they within easement). -dimensions and cross-section verification -longitudinal slopes and side slopes -spot elevations JUL 2`0 2006 Jul 20 06 05:30p p.5 -permanent erosion control measures (drop structures, riprap, etc....) -tie-in to pipes, pans, curbs, etc.... -weir size (elevations, size, opening, etc.) S RECEIVED R -available freeboard JUL 2 0 2006 -landscaping infringement on swales 3. Pipes -size and type -slopes (as -built and comparison to minimum 0.4% slope) -pipe capacity calculations if slopes are significantly altered 7'$$ -invert elevations . -installation and backfill material -cover -encasement and clearance from other utility lines close by -joints 4. Concrete Pan Channels -size -slope -super elevation -cross .section -thickness -elevations gh 5. Inlets -size and type Jul 20 06 05:31p p.6 -size of opening (or name of standard used) -grate elevation -invert elevation -box size t,*6. cross pans -size -type -grade -elevation -cross-sectional depth -tie-in to curb and gutter t* 7. Culverts -size -type -invert elevation .-headwalls t4p, 8. onderdrains -size -type -cover backfill -geotextiles -cleanouts 9. Curb cuts -size STORMWATER RECEIVE® JUL 2.0 2006 -tie in to Swale, pipe, etc... B. Certification of Grade Elevations Adjacent to Drainage Facilities: Jul 20 06 05:31p p.7 STORMWATER RECEIVED 5D 83,( -minimum opening elevations JUL 2-0 2006 �gr:).i -top of foundation elevations -71,4:j -comparison to 100 year WSEL's (Freeboard requirements and floodplain issues) C. Certification of Erosion Control Measures: Ak. Permanent Measures: -Permanent vegetation (6" bare spots and weeds under control) -riprap -riprap bedding -drop sections -sediment basins/water quality ponds -netting mats/blankets -mulching f4f-2. Temporary Measures: -mulching -inlet filter installation -check bale dams -seeding and temporary vegetation -silt fence D. Site Cleanup After Construction .construction clean up smoothing of ruts -reseeding ,i s. Statement of Compliance This certification is signed and stamped and by signing this form the engineer(s) attests that they have inspected Jul 20 06 05:31p p,g the site and to the best of their knowledge the as -built conditions of the drainage facilities are as described in the above form and in the redlined plans enclosed. Failure to properly disclose all known information could result in the rejection of this certification and prevent the release of any Stormwater Utility holds on Building Permits and/or Certificates.of Occupancy. v4,_ Signature and Stamp by a Colorado Registered Professional Engineer. .STORMWATE'R RECEIVED JUL 2`0 2006 Jul 20 06 05:31 STORMWATER RECEIVED JUL 2'0 2006