HomeMy WebLinkAboutLot Certifications - 08/24/2006AM-18-2006 11:06 FROM:
TO:2216619 P.2
City of Fort Collins
Utilities .
electric a stormwater a wastewater • water
CERTIFICATION OF LOT GRADING
Pursuant to City Code § 26-544 and
City Land Use Code § 3.2.2 (e)
Date: August 17.2006
Permit Application No. r of:4�-Zi
Address: 1115 Bateleur Lane
Lot: 20 Block:
Subdivision Hearthfire Subdivision 2n0 Filing
STORMWATER
RECEIVED
AUG 18 2006
(,(Print) Wyatt M. Knutson . a Colorado registered professional engineer,
verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me
or someone under my direct supervision, and verify construction of all stormwater facilities and grading is
complete, and the elevations and drainage patterns shown on the attached drawing(s) which were
developed from a survey performed on (Date) August 17. 2006 accurately and truly depict the
elevations and drainage patterns as they existed on the date of the survey. Based on this information, I
certify that (check one):
o The elevations and drainage patterns of the lot/site are in substantial conformance with the City
approved drainage and grading plan for the property (information attached). SEE NOTE.
The elevations and drainage patterns of the lot/site as measured are in general conformance with
the City approved drainage plan with exceptions (information attached). In my professional
judgment the elevations and grading of the lot as constructed is functionally adequate and will
allow for stormwater drainage consistent with the approved drainage plan.
SEE NOTE.
signat e, PE stamp)
(address of signing party)
NOTE:
A COMPLETE certification must be submitted. Including but not limited to drawings of the lotfsite showing the approved design and
as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written
mfonnationlexplanadon of discrepancies, etc. to:
Fort Collins Utltitles (970) 221.6700
700 Wood Street
Fort Collins, CO 90621
At least Two weeks Prior To Requesting A Certificate Of Occupancy For The Property
Rev 1/1/05
AUG-18-2006 11:06 FROM:
TO:2216619 P.3
Final Grade Assurance Observation:
Per the clients request, a representative of SECURE has visually observed and
measured elevations of the grading around the home at the site referenced below.
The following summarizes our observations and opinions at the time of our visit.
SECURE
CONSULTING ENGINEERS
A CTL i THOMPSON COMPANY
Client: A;, ss. 0 A• Ver-i Site Address: ii/S
Secure Job#: SFvv9i7 Lot: w.�Block• Filing:
,
Date: � Contact: Subdivision: •iorlZe -;g Z. �a+•.•�
Backeround Information:
Referenced Grading Plan: <�roI .Aiurs�+1 a1/
Dated: Job#:
Summary of opinions:
)8(It is our opinion that the top of foundation and grades
around the home are consistent with the above
referenced grading plan or are a functionally adequate
substitute.
❑ Rejected (2nd observation required)
Corrective action:
Field Representative -eCs=jxXti Date
Site:
Secure Foundations, LLC • 211 West Magnolia Street, Ft. Collins, CO 80521 • Ph: 970-472.6255 0 Fax: 970472-6256
RUG-18-2006 11:06 FROM: TO:2216619 P.4
9'
KE
9E
------ tii�9'��f fie E 10 FaOD'_
:.
lop
I �
r•
WAN,, —
- I TE L A N -
71
10'V,y)
NE5A714FIM
*WNv Fl WAo
LAtClk MOUtW. O
'.AM-18-2006 11:07 FROM: TO:2216619 P.5
A \ FG=10.7
FG=09.47 \
2+ 63. 2,N
\ FG=08.93 \
\ ti
263.72bE .
8"PVC S/L
110
FG=O
\ \ ss p \
\ \ Sip
4
02.60 \\ \ 8"P w
N