Loading...
HomeMy WebLinkAboutSite Certifications - 04/21/2003C. April 21, 2003 Project No: 1552-01-96 Jay Barber City of Fort Collins Stormwater Utility P.O. Box 580 Ft. Collins, Colorado 80522 SHEAR G�- Re: Tract J, HearthfireP.U.D. First Filing; Fort Collins, Colorado 3� c�� CommunityBuildingMinor Amendment Dear Jay, Shear Engineering Corporation was present at the above referenced site on Wednesday, December 18, 2003, Thursday, December 19, 2003 and Monday, January 27, 2003 for curb and gutter construction observations. Shear Engineering Corporation was present on Tuesday, April 8, 2003, Monday April 14, 2003 and Friday, April 18, 2003 for final grading observations. All curb and gutter construction observations were made to confirm that the curb and gutter in the community center parking lot drains properly and was completed in substantial compliance with the.direction, details and specifications noted on the Tract J, Community Building Minor Amend ment.amended subdivision plan sheets for Hearthfire P.U.D. First Filing; sheet 4B — Tract J Improvements Detail,.sheet 38A — Tract J Grading Detail, sheet 41 A — Tract J Drainage Detail and sheet 43 A — Detail Sheet, Streets and Concrete, by Shear Engineering Corporation, City of Fort Collins Director of Engineering approval date 04/18/02. All final grading observations were made to confirm that final grading functions properly and meets the intent of the Hearthfire P.U.D. First Filing; Tract J Grading Detail. Sheet 38A — Tract J Grading Detail is attached for your immediate reference. The valley pan designed at the northern property line of this lot had not yet been constructed at the time of final grading certification. The grade at the location of this pan has been prepared for it's construction and it is the understanding of Shear Engineering Corporation that it will be constructed in the near future. Shear Engineering will verify the complete construction of this valley pan with a supplement to this letter. All curb and gutter construction drains properly and was completed in substantial compliance with the direction and details of the amended subdivision plan sheets referenced above. All final grading functions properly and meets the intent of the Hearthfire P.U.D. First Filing; Tract J Grading Detail. Shear Engineering Corporation has obtained record field shots, which are indicated on the attached sheet 38A - Tract J Grading Detail (scale: 1" = 20') and the parking lot enlargement (scale: 1" = 10') of sheet 38A — Tract J Grading Detail. J2-�,-P 143167 4836 S. College, Suite 12 Ft. Collins, CO 80525 (970) 226-5334 Fax (970) 282-0311 www.shearengineering.com PAGE 2 April 21, 2003 Project No: 1552-01-96 Re: Tract J, Hearthfire P.U.D. First Filing; Fort Collins, Colorado Community Building Minor Amendment If you have any questions concerning our observations, please call (970) 226-5334. Sincerely, * OZ." M. Adam Denton Shear Engineering Corporation BWS / mad attachments M. City of Fort Collins Building Department Hearthfire, Inc. John Walz Enterprises Page 2 No Text N i w �� .align, 0:9111111111 101 "Awl i.� NOEH W, .� .. , 'e : lea•• �' r 5r NMI mom EQ !�ieeeeeee - :. woe®♦�� •�e�� � � • � ►wee'®ee��i1�� / � e