HomeMy WebLinkAboutLot Certifications - 11/19/2007 (2)€::ifv of Fort collie-ts Utilities electric • stormwater • wastewater • water CERTIFICATION OF LOT'GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: 10 tl /Z�7.o 6 7 Permit Application No. Zjer /lj_� Address: 132-f geaxtildu:;&r - Cf- Lot: $'7 Block: Subdivision: -Fm), 1W, (,(Print) Kevin E. Forbes, P.E. , a Colorado registered professional engineer, have personally inspected the above referenced property in the City of Fort Collins, Colorado, and verify that construction of all stormwater facilities and grading there is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date) /,/aLI 7 _ Zckil , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): DEC The elevations and drainage patterns of the lot are in substantial conformance with the City approved drainage and grading plan or revised grading plan for the property (information attached). SEE NOTE. ❑ The elevations and drainage patterns of the lot as measured are in general conformance with the City approved drainage plan or revised grading plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot as constructed is functionally adequate and will allow for stormwater drainage consistent with the appror.-}image plan. SEE NOTE. ignature, PE sta (address of signing .O RE NOTE: A COMPLETE certification must be submitted, including but not limited to drawings of the lot/site showing the approved design or revised design and as -built surveyed elevations of all structures and drainage and grading features (e.g. swales, retaining walls, lot corners), written information/explanation of discrepancies, etc. to: Fort Collins Utilities (970) 221-6700 700 Wood Street Fort Collins, CO 80521 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property GRADING CERTIFICATION PLAN LOT 57, HEARTHFIRE P.U.D. FIRST FILLING 1321 HEARTHFIRE COURT, FORT COLLINS COLORADO SCALE: 1 " = 30' 9 • chaos. COURT w Ej m�MF^1l Ro?ss S 9g• D> V19 A� . h A 84.9 x a4.7 Q��l�,es� �} 97.5 84.3 'J`'C�O lyj 96.2 x 84.086.8 A>, \ 88.1 OMB 3 94 95.0 B � 81.8 8.3.7 81.5 86.0 83.4 Ois• � ZJ ;1�1 x.8\,3.5 82.8 1.4 Nov 13 07 11:41a DPH 1-970-224-5046 p.2 DATE: April 18, 2007 ADDRESS: Mr. Mark Daugaard DPH INC. P.O. Box 270433 Fort Collins, CO 80527 PROJECT NUMBER: 07-4314 SUBJECT: Excavation Inspection of Lot 57, Hearthfire P.U.D., 1321 Hearthfire Ct., City of Fort Collins, Larimer County, Colorado REFERENCED SOIL REPORT: Scott Cox No. 1821-09-01-01 SOILS EXPOSED IN EXCAVATION: Lean Clay, Sandstone On April 17, 2007, we visually observed the excavation for the proposed residence at the above referenced site. At the time of our observation the excavation was complete. The excavation ranged in depth from six (6) inches to six (6) feet below original grade. Based on our observation the soils appear consistent with the above referenced soils report, which recommends that the structure be supported by a continuous spread footing foundation bearing on native, undisturbed soils. An exterior perimeter drain should be installed based on the soils encountered at this site. It is further advised that backfiil around the foundation should be compacted to reduce settlement and slope at a 100/9 grade away from the foundation walls. Downspouts and sill cocks should discharge into splash blocks or long downspout extensions that extend beyond backfill limits. FOR AND ON BEHALF OF CDS ENGINEERING CORPORATION Inspected by: Robert R. Greenwald II, P.E. 165 2nd Street S.W. - Loveland, CO 80537 • (970) 667-8010 - Fax: (970) 667-8024 dMPROVEMENT LOCATION 'CERTIFICATE LOT 57, HEARTHFIRE P.U.D. IST FILING, 1321 HEARTHFIRE COURT 0 SCALE: IMPROVEMENT LOCATION CERTIFICATE FOUND 4- REBAR LS/25372 I hereby certify that this improvement location certificate was prepared for MARK DAUGAARD, and that it is not a land survey plat or improvement survey plat, and that it is not to be relied upon for the establishment of fence, building, or other future improvement lines. I further certify that the improvements on the following described parcel on this date, NOVEMBER 07, 2007, except utility connections, are entirely within the boundaries of the parcel, except as shown, that there are no encroachments upon the described premises by improvements on any adjoining premises, except as indicated, and that there is no apparent evidence or sign of any easement crossing or burdening any part of said parcel, except as noted. cojjRr LEGAL DESCRIPTION: LOT 57, HEARTHFIRE P.U.D., 1ST FILING 1321 HEARTHFIRE COURT CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO Signed: J OB NS P.L.S. 7899 Date: O RF.G. 99