HomeMy WebLinkAboutLot Certifications - 10/29/2008Utilities electric • stormwater • wastewater • water City of Fort Collins CERTIFICATION OF LOT GRADING STORMWATER Pursuant to City Code § 26-544 and RECEIVED City Land Use Code § 3.2.2 (e) Date: 10-07-08 OCT 2 9 2008 Permit Application No.: Address: /Gy/ Legal Description: Lot 7 Country Club Corners Third Filing Replat /�- Subdivision: Club Corners Third Filing Replat (,(Print) J�• ItitF £'^^610"500 , a Colorado registered professional engineer, have personally inspected the above referenced property in the City of Fort Collins, Colorado, and verify that construction of all stormwater facilities and grading there is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date) 10-06-% , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the lot are in substantial conformance with the City approved drainage and grading plan or revised grading plan for the property (information attached). SEE NOTE. ❑ The elevations and drainage patterns of the lot as measured are in general conformance with the City approved drainage plan or revised grading plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot as constructed is functionally adequate and Will allow for stormwater drainage consist j4cfS roved drainage plan. SEE NOTE. O."''EjF By: (sign uri?;PEf3Qi) 0. �1665 0Ir •'�'�p�f wq.2� L Z, S"ft 2eo NOTE: A COMPLETE certification must be submitted, including but not limited to drawings of the lotfsite showing the approved design or revised design and as -built surveyed elevations of all structures and drainage and grading features (e.g. swales, retaining walls, lot corners), written information/explanation of discrepancies, etc. to: Fort Collins Utilities (970) 221-6700 700 Wood Street Fort Collins, CO 80521 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property aMA�rl v�og STORMWATER October 7, 2008 RECEIVED Mr. Jay Barber (SIT 2 9 2008 City of Fort Collins Stormwater Utility 700 Wood Street Fort Collins, Colorado 80521 Re: Drainage Certification for Lot 7 Country Club Corners Third Filing Replat Dear Mr. Barber, We recently surveyed grading and building improvements associated with the Lot 7 at the Country Club Comers Third Filing Replat. The building and improvements are located on the east of College Avenue and south of Willox Lane in Fort Collins. Spot elevations were checked at pertinent locations and compared to the grading plan to verify whether the building construction met the intent of the approved grading and drainage plan. The enclosed drawing shows both the grading plan and as -built spot elevations. In general, the building construction meets the requirements of the grading and drainage plan and there is positive drainage away from the building on all sides. The finished floor elevation of the building is slightly above the finished floor elevation shown on the approved grading plan. Very little grading was performed as part of this project due to existing curb, gutter, and sidewalk elevations. However, the intended drainage patterns are met by the grading of the building's finished floor and corner elevations, with slopes set for drainage to flow radially outward from the building. It is my recommendation that the Certificate of Occupancy be released for Lot 7 at the Country Club Corners Third Filing Replat, since the Contractor constructed the building to meet the design drainage patterns. If you have any questions, please call. Sincerely, R Leif Embertson, P.E., CFM Water Resources Engineer Ayres Associates Engineers/Scientists/Surveyors 3665 JFK Parkway, Building 2, Suite 200, Fort Collins, CO 80525-3152 (970) 223-5556, FAX (970) 223-5578 www.AyresAssociates.com Lot7_Letter.DOC 32-1361.00 nPwtyA LOT 7 • • `/O ll` • • �•� L ti]Ei)NMI .� rwAo NOTES: 1, ANYCURB.GVPIERORSIDEWALKOAMA(iEU WBHTHECONSTRUCRON SMALL BE REPAIR AN D BROUGIR BACK TO f TS E%ISUNG CONORION OR BEffER. 2. WATERSMR CESHALLBETYPE"K"COPPERINSTALLEDPERCRY STANOA . N Y s. BEWER'.iF.INICE SINLL BE4"SOR 95 WCINSfALLEDAT 2%MINIMUM SLOPE. 4. ALL DISRIRBED AREAS SHALL BE SEEDED ANO MULCHED. 5. THE RNISHM FLCOR ELEVAT ISTHE SAME ASTHE MINIMUM OPlTIING ATTME BUIWING AND IS THE MINIMUM ELEVADCN FOR PROTECTION FROM THE 1 WYRSIli 6. ERO"aIONCUMRULFIXtTHKP ECTSHALLCONSISTOFINSTALLING ® WATTLES IN THESWALESOURI AND EASTOFTHE BUIMINGANDCNTHE TOW A0.IACEM CURBINLETS, ]. ANYSEDIMEMDEPOSTIEDONADJA DRN MDPMKINGAR � SHALLBECLEANEDO LY. ____ <_ --- LOT SMICIGW 1IS (M. oMulrl. _ .VL �MRMUS M36'ME �_ — WOC NO Ylmr A}rTI .IrO fVMA All 3 M1nE M SWE v AMA .q.,...mgyn�rquprva[rrtua u.,mm �I .Y.t .YII. ��:snra � smM .°wM, _tmwm OV WWI) KAAW nAw—r pp Am .� YrYwwrtml WATTLES mrML M,., p (q 6v ) b 3/4ry WO I FN r,aa nMe r. man . PK 10 5 0 10 20 SCALE: I"- 10' CA11 UMV HOnR 1114)11 LEHiFA OF COUORADO 811 mftfy} a-w9fss oAn N .bvw¢ rPl OW WOE Vrd VAR R11111F KMeer3 a WIWIPIWO MBHA u1MRs 00 9°y@YY6 F�SP l p� 0 Q U �m 4 W �a0 �0— W g WR �wm Ors mw 3 (A V) m W Ir Z u a a a 0W 0 UZ �a l7 F Ii °z Zo a 0 U= 0 J 2 Mu I I/[ M su 3 M � .a Ip{.% Ir w aryeuvi Ilq aI Ym W w+hgan s is a aWlq eba n A a un en w .Aw W rceaaia to w me� ", iry ea.r.A marpwl6 +aM. 4. nIM w al p MArt a4 M q rw 6 .�w+rm+�Iw,a �.n. m.n.nWq ne. q�� xed.+a Aw1.. r.lsr.rrwrrMl.rw�l.r o jF. b IN I,g IA, M. mh. NMMrVr ■ .uA mrpYqur a.,gnpwm rswr �Irlrr.Wrrgar.....r o z z rM..�rrBr -;; �'g G. w glaHw rr rw..l an .bv q WO m. rlro. • �+wn r r'.arrt' r.. m wry pr.r. r A.rr. rr...I Y..q ril ..r r 6 MA' MrYYrYq Ar Ym{ealnn MlaemlawnM]M .�A IM�Ma'I1r Ir Yw nIY /t swa��wwala vialns iwalMMAr Y YF 4 wl/..r HI. rO a Aw+NI 10 YI M M W M MI att a P COLUHS ROVAL TYPICAL WATER SERVICE UTILITY PLAN APPROVAL e xlva oETAa rIY®.® rtulw® mmoe mmlc T® a/A A� Ap oArz F4�WC rc NM cwW STONIIWAIER Mope r_ a. i/am Imv q Q1M1 APPROY : coxsmucnory DUARS ass 11 "'Yiw» r Ss a w NMR CHECKED BY: IMM s IMSTEWAMA URJn CAT CHECKED BY: snWwv.Rn ulun Dore CHECKED BY: eARAD a AEf.4A1MM1 MR PRo3. rvo. IoeTa56ao CHECKED BY: wR 2 OF E