HomeMy WebLinkAboutLot Certifications - 07/16/2014Utilities
electric• storrnwater. wastewater. water
T
City,
700 Wood St.
PO Box 580
F6M Collins
Fort Collins, CO 80522.
970.221.6700
970.221.6619 fax . 970.224.6003 TDD
ufiUffes@fcgovCom . fcgov.Com/ulififfes
- CERTIFICATION OF LOT GRADING
Pursuant to City Code § 26-W and City Land Use Code § 3.2.2 (e)
Date:
Permit Application No. B 13o GC, o4 a; r1
Address: Wiva "A, - f-otcaaseb e�. Sic V-4++c.
Lot: Z Block: "—
Subdivision: Pre- sA Af_&_ ZI.10
(,(Print) ZaSCU"A E. f3>4%Z� • a Colorado registered professional engineer, verify that the
-= - - - - above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately
qualified professional under my direct supervision, and verify that construction of all stonnwater facilities and grading
is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed
from a survey perfomied on (Date): accurately and truly depict the elevations and drainage
patterns as they existed on the date of the survey. Based on this information, I certify that (check one):
❑ The elevations and drainage patterns of the lottsite are in substantial conformance with the City approved
drainage and grading plan for the property (information attached). SEE NOTE.
9 The elevations and drainage patterns of the IoVsite as measured are in general conformance with the City
approved drainage plan with exceptions (information
and grading of the lot/site as constructed are fu
approved drainage plan, and will affect stormwa
with the approved drainage plan. SEE
By:
the elevations
to the specifically
a manner consistent
xr•i ruj LG *mvo-4-ac
NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for Ute WOW, including but not limited to drawings of the lotfsite showing the approved design and as -built surveyed
elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written
information/explanation of discrepancies, and other Information necessary to confirm the above certification to:
Fort Collins Utilities
700 Wood Street
Fort Collins, CO 80521
(970) 221.6700
Rev. M27/12 Submit Two Weeks Prior To Requesting A Cerdflcadon Of Occupancy For The Property
ADVANCED
ENGINEERING, LLC
STRUCTURAL DRAINAGE DRAFTING
OVERLOT GRADING OBSERVATION
Site Observation Date:
Site Observation by:
Site Address:1�
Site Legal: "-r-
Site Plan and/or Grading
We have observed portions of the above referenced site. During our observations our representative measured the relative
elevations at the lot sides and comers, top of foundation, and lowest openings. The observed elevations were compared to the
Site Plan and/or Grading Plan referenced above. Based upon our findings it is our opinion that:
The elevations as measured are in general conformance with the above noted Site Plan and/or Grading Plan.
The elevations as measured are in general conformance with the above noted Site Plan and/or Grading Plan with the
following exceptions:
It is our opinion these exceptions, as noted above, should not adversely change the grading scheme as shown on the above
referenced plan.
lq During our observations our representative noted that the as measured elevations do not conform to those indicated on the
above referenced Site Plan and/or Grading Plan. However, it is our opinion the grades as measured should provide an
adequate substitute to the above referenced grading scheme (see comments below).
g See the attached "As -Built' grading plan.
The elevations measured are not in conformance to the above referenced Site Plan and/or Grading Plan. Deficiencies
include:
Other comments and/or observations:
r,
m C tea fir Lc►J6t 7t1Mt nIGrC�t7 EO
t S• oCF sr .��CTY a4�' 7o Ace 6xrSTMI�� LAntOSC. t
Limitations: It is our opinion the above referenced site, as graded on the observation date, should not interfere with offsite flows
unless the grades are changed or barriers are created such as fences, garden terracing, sidewalks, and/or any landscaping which
may change the established flow patterns by diverting or slowing runoff flow. Backfill adjacent to the residence may settle over
time, this settlement may allow ponding to occur adjacent to the foundation walls. To prevent this ponding and related problems,
the backfill adjacent to the residence must b Y d maintained to ensure that runoff will flow away from the foundation.
The grades measured were compared o own on the above referenced site plan and/or grading plan. Other
minimum grading requirements w ' 46 8 ils report or by other construction documents are beyond the
scope of this report. �: ��N q,��•,p�
33739
7 7-Reviewed by: Jason E. Baker, P.E. �.c ••.
�SSlnni, E�
229 12'0 Street SW, Loveland, Colorado 80537 Telephone 970-278-1909
.1
No Text
/
\»
Q
�
%
:
y
y
) ,
Z
_
�
\
\ƒ \
ui
�
�
e
I>
rl ,
\ .
m
1>
C@2\2
-t�ul 6
�\�/j)) \
mOm
70 §
_
} \�
® §/!
{ ®�`
r
RIDGEQ4> CON52 SERVICES A D VA N C E D
--\ ® ENG.NEEmNG,LLc
--05
Daniel Mogen
From: Steve ONeal <onealsteve@sbcglobal.net>
Sent: Tuesday, July 15, 2014 7:59 PM
To: Daniel Mogen
Cc: Nerio Baray
Subject: Re: Lot 2 Hearthfire 3514 Hearthfire Drive Grading Cert
Dan,
I left you a voice message, but will confirm in writing. The final grades were shot of the property and
do adhere to the general grade and drainage on the site plan.
The homeowners, Gary and Linda Ellis, asked us to leave this dirt for their landscape use. The plan is
to add this material to the top of existing grade directly off their patio to raise it a few inches higher.
They will maintain their grade lines while doing this to insure proper positive drainage as per the site
plan.
You've seen how we normally leave our finished sites, so know that we typically haul off all excess
dirt. In this case we were asked to leave the dirt to avoid the significant cost to haul offsite, then re
load and haul back to the property after final inspection.
The balance of the property has been fine graded complete with compost as required where lawn and
landscape work is to be placed and that work does adhere to the filed site plan on file with the permit
application and was signed off by the engineer of record.
The bulk and remainder of the dirt will be used to create some landscape berms near the rear of the
property where there are now low areas towards the fence, again while maintaining the prescribed
drainage and drainage swales away from the house as required.
Ridgeway Construction Services will not be performing this work as the homeowner will perform the .
landscape materials and work this summer.
Please let me know if you have any other questions or concerns.
Thanks,
Steve O'Neal
Ridgeway Construction Services LLC
On Tuesday, July 15, 2014 3:16 PM, Daniel Mogen <dmoaen@fcaov.com> wrote:
Steve, there is a large pile of dirt in the backyard. Can you tell me what is going on with that?
Thanks,
Dan
0 -
Sent from my iPhone
On Jul 15, 2014, at 10:36 AM, "Steve O'Neal" <onealsteve @ sbcalobal. net> wrote:
Thanks Dan
Sent from my iPhone
On Jul 15, 2014, at 10:30 AM, Daniel Mogen <dmogen@fcgov.com> wrote:
Hi Steve,
I had not received this grade cert previously so I haven't had a chance to inspect and sign off. I will get out
there and take a look as soon as I can. There is a chance I may be able to get to it this afternoon; I will keep
you posted.
Dan
Dan Mogen, El
Stormwater Engineer
City of Fort Collins Utilities
(970)224-6192
dmogen@fcqov.com
From: Steve ONeal rmailto:onealsteve@sbcolobal.netl
Sent: Tuesday, July 15, 2014 8:53 AM
To: Daniel Mogen
Subject: Fw: Lot 2 Hearthfire 3514 Hearthfire Drive Grading Cert
Dan,
Good morning. Just following up to see if you had received these final grade certificates and had a
chance to do the final sign off for our Certificate of Occupancy.
Thanks,
Steve O'Neal
Ridgeway Construction Services LLC 970-391-9003
On Monday, July 7, 2014 1:37 PM, Jason Baker at Advanced Engineering<iason@advancedengineerinollc.com> wrote:
Please see the attached grading cert for your review. Let me know if you have any questions.
Thanks,
Jason E. Baker, P.E.
President
Advanced Engineering, LLC
229 12ch Street SW, Loveland, CO 80537
970-278-1909 office, 970-690-4616 cell
iason@advanceden-gineeringlic.com