CERTIFICATION OF LOT GRADING
Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e)
Date: August 18, 2014 NFZ.
Permit Application No. B1305542 CO rdewseb �zoliot+
Address: _ 2856 Denver Drive
Lot: 184 Block:
Subdivision:.. Riciden Farm — Filing Six
1,(Phnt) Tom Cope , a Colorado registered professional engineer, verify that the
above referenced property in the City of FortCollins, Colorado, has been inspected by me or an appropriately
qualified professional. under my direct supervision, and verify that construction of all stormwater facilities and grading
is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed
from a survey performed on (Date): August 18, 2014 accurately and truly depict the elevations
and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one):
The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved
drainage and grading plan for the property (information attached). SEE NOTE.
Ei The elevations and drainage patterns of the lot/site as measured are in general conformance with the City
approved drainage plan with exceptions (information attached). In my professional judgment the elevations
and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically
approved drainage plan, and will affect stormwater drainage on and off the lot/site in a manners;potiVRXfltuj)
With the approved drainage plan. SEE NOTE.
By:
(signature, PE stamp)
1601 37v' Street. Evans, .CO 80620
(address of signing party)
NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the lot/site, including but not limited to drawings of the lot/site showing the approved design and as -built surveyed
elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written
informationtexplanation of discrepancies, and other information necessary to confirm the above certification to:
Fort Collins Utilities
700 Wood Street
Fort Collins, CO 80521
(970) 221.6700
Rev. 1127112 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property
-51-
3j
S.1
. , I /�?
4�/
87.90
z)
...... .....
7
K-7
0,•
86.82
a
/87.43
X
O 01, )o
q & 16) e-
LEGEND 2856 DENVER DRIVE
G P -'DE 8 R E K / 3 �i L SCALE: I" = 20'-0'
.............
PROPERTY ME .
---------------------:TOP OF FOUNDATION i 89.20
........................ ......... .............
----------------------
- -----
;MAX FINISH GRADE ELEV
t 88.53
E!S'cME4T AT FOUNDATION WALL
............ .. - ..... .... ..... ..... .. ... . ...
:DRIVE SLOPE 7,44v
..... .......... - ............ ....... .... :FRONT
GARAGE F.F.
88.70
ET 20' FRONT SETBACK 15' jP4.EASENTENT;
;GARAGE FLOOR ELEV. 8 9.12
I SIDE STREET SETBACK 9' jT!LlrY E45FINIENT AT ENTRY DOOR
. . . .... .... .. . ..... ...... ........
IS' REAR S,-TqlrK 5' UT!LI7'f c- %' )VAEmT ELEV. OF FOOTING BOTTOM
OG 86.20
a FRONT OF GARAGE
SITE a GRADING PLAN CLIENT
PLAN #TS-1858 JjUPI;Ef HOMES, LLC RMG ENGINEERS
7251 N ',ifh 3T. SLOG L. TE ?OQ
rqEELr(. C0j 90-�34 1601 37'h SW�E'
r I I lqAJFLG
-:-,-�FN F4-:16 y?JG' PP,)jE,'T WjJ-483 ENGINEERS _-j
J - -
F
32" 125'
;j L
�;
i
Architecture Materials Testing
Structural Q!.MG Forensic
Geotechnical Civil/Planning
ROCKY MOUNTAIN GROUP
Job No. 140618
September 26, 2014
City of Fort Collins Utilities
700 Wood Street
Fort Collins, CO 80522
dmogen@fcgov.com
Attn: Dan Mogen
Re: Lots 162 thru Lots 193
Rigden Farms, Filing No. 6, Final Plat
Fort Collins, Colorado
Dear Dan:
This letter is provided to the City of Fort Collins to discuss the drainage certifications for Lots
162 thru 193 in Rigden Farms, Filing No. 6. These lots were changed from the originally
proposed attached single family dwellings to detached single family dwellings as evident by the
submittal of the Site and Grading Plans to the City of Fort Collins. These lots were approved by
the City of Fort Collins to be constructed as detached single family homes.
The changes to the lots included detached garages and house foundations and each structure was
evaluated separately to recommend the top of foundation elevation and minor adjustment to the
grading elevations.
The original intent of the subdivision master grading plan was followed with the lots draining as
proposed in the subdivision grading plan. This was provided with each lot being designed and
reviewed as a detached single family home.
I hope this provides the information you have requested. Should you have questions, please feel
free to contact our office.
Cordially,
'Do REG
vC�:• s M� c
�.� 9/29/14
24995
Thomas M. Cope, P.E. uS�ONAt
Professional Engineer
Southern Office: Central Office: Northern Office: Monument: 719.488.2145
Colorado Springs, CO 80918 Englewood, CO 80112 Evans, CO 80620 Woodland Park 719.687.6077
719.548.0600 303.688.9475 970.330.1071 ErbiUKurdistan Iraq: 0750 192 99 44
Ulaanbaatar, Mongolia: 976 99106671
www.rmgengineers.com