Loading...
HomeMy WebLinkAboutLot Certifications - 11/17/2015Utilities City, of electric• stormwater.-wastewater. water Fort Collins For Wood , PO Box 580 Fort Collins, CO 80522. 970.221.6700 970.221.6619 fax • 970.224.6003 TDD utilities(a)fcgov.com . fcgov.com/utififfes CERTIFICATION OF LOT GRADING Pursuant to City Code C4 26-544 and City Land Use Code 4 3.2.2 (e) Date: November 17, 2015 Permit Application No. B1502043 Co r41c0.7c i "/-7 Address: 3215 Bryce Drive Lot: 308 Block: n/a Subdivision: Riaden Farm Filing Six (,(Print) Steven M. Strickling a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): October 29. 2015 accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. ❑ The elevations and drainage patterns of the lottsite as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are.functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormwater drainage on and off the IoUsite in a manner consistent with the approved drainage plan. . SEE NOTE. �. � - 31237 '•. I I-1�2015 : tea; O'O '• •'' For and On Behalf of NAL ECG CIVAS Engineering, LLC By: (signature, PE stamp) 10056 Brisbane Lane, Littleton, CO 80130 (address of signing party) NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the IoUsite, Including but not limited to drawings of the IoUsite showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written Information/explanation of discrepancies, and other Information necessary to confirm the above certification to: Fort Collins Utilities 700 Wood Street Fort Collins, CO 80521 (970)221-6700 Rev. 1127112 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property ELEVATION AND DRAINA Surveying, Inc. 6841 SOUTH YOSEMITE STREET 1100 CENTENNIAL, CO 80112 C 307 OUTLINE OF EXISTING HOUSE (DRAINAGE CERTIFI PASSED ON 03-1 c � � TRACT AP BRYCE DRIVE 51' R.O.W. NO Me OUTLINE OF EXISTING HOUSE (DRAINAGE CERTIFICATION PASSED ON 03-21-15 ,) 0 20 40 SCALE: 1"=20' PREPARED FOR: MERITAGE HOMES . LOT 308. RIGDEN FARM FILING SIX, CITY OF FORT COLLINS. COUNTY OF LARIMER, STATE OF COLORADO; ALSO KNOWN AS: 3215 BRYCE DRIVE ELEVATION AND DRAINAGE CERTIFICATE I HEREBY CERTIFY THAT THE ELEVATIONS AND DRAINAGE PATTERNS SHOWN WERE DEVELOPED FROM AN SURVEY PERFORMED UNDER MY DIRECT SUPERVISION ON THE DATE SHOWN. TO THE BEST OF MY KNOWLEDGE AND BELIEF, THE DRAINAGE FOR THE LOT SHOWN (HEREON WAS MEASURED TO THE NEAREST TENTH OF A FOOT AND ACCURATELY REFLECTS THE DESIGN OF THE APPROVED AREA GRADING PLAN PREPARED BY THE ENGINEER OF RECORD. ELEVATIONS AND PATTERNS MAY CHANGE SUBSEQUENT TO THIS AS A (RESULT OF NATURAL AND/OR MAN—MADE OCCURRENCES. THIS DOCUMENT 15 NOT AN IMPROVEMENT LOCATION CERTIFICATE OR LAND SURVEY PLAT. No Text