Loading...
HomeMy WebLinkAboutLot Certifications - 04/07/2014 (39)City Utilities electric. stormwaterwastewater. water of FortFortPOCollins 70W00dst Box 580 Fort Collins, CO 80522 .976.221.6706 970.221.6619 fax . 870.224.6003 TDD utilities@fcgov.com . fcgov.com/utililfes CERTIFICATION OF LOT GRADING Pursuant to City Code§ 26-544 and City Land Use Code §.3.2 2 (a) Date: March 21, 2014 fclu sut 4/714 Permit Application No. B1305059 Address: 2808 Denver Drive Lot: 192 Block: Subdivision: Rigden Farm — Filing Six (,(Print) Tom Cope :a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately "qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): March 21, 2014 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): The elevations and drainage patterns of the lot/site are insubstantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. ❑ The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lotisite as constructed are functionally adequate and equivalent to the: approved drainage plan, and will affect stormwater drainage on and offthe loUsite in a m5 with the approved drainage plan. SEE NOTE. By: of signing party) NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the lot/site, Including but not limited to drawings of the lot/site showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, tot comers), written information/explanation of discrepancies, and other Information necessary to confirm the above certification to: Fort Collins Utilities 700 Wood Street Fort Collins, CO 80521 (970) 221-6700 Rev. ;M7112 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property z 5 "0 30, R, / 'C:5, �,�3j3315Q 8 85.30 A � 3 , �^• D 1•I I �O �4i-tea 185.90 Cyr ¢2j.Sn% Df N�fR �RI �f AF 5 ,`y a / ..� ✓ 8 �5. -o�T4w 0505� L GE LND : 2808 DENVER DRIVE GRADE BREAK/SWALE: SCALE: I" - 20'-0" ......_...._._......__._..-......_..........-.........._..._....._.._...__.... - PROPERTY LINE :---•---------------- ': TOP OF FOUNDATION i 87.80 ......._....__.._._........_._._._.._....._......__._.._._..._......w_....... -.._.. SETBACK -------------------------- - i MAX FINISH GRADE ELEV i EASEMENT: ------------- AM OUNDATIOfV_WALL•.,,, 87.t3 (_...............r._.._ ---- DRAINAGE DIRECTION: I DRIVE -SLOPE i 8.32% FRONT GARAGE F.F. 87.30 I 9' SIDE SETBACK 0 20 FRONT SETBACK O7 15' J.P.A. EASEMENT � ............. GARAGE FLOOR ELEV. t O2 15' SIDE STREET SETBACK O5 9' UTfLITY EASEMENT ? AT ENTRY DOOR i 87.72 i.._.-.._._._._..._..__._.._._.._..._.....-._..._....... _ _...-.E.._..�_._._. O3 15' REAR SETBACK © 14' UTILITY EASEMENT i ELEV. OF FOOTING BOTTOM ` v FRONT OF GARAGE 84.80 SITE a GRADING PLAN CLIENT PLAN #TS-1782 JOURNEY HOMES. LLC RMG ENGINEERS 7251 W. 201h ST, BLDG L. STE. 200 LOT 192 - 4,5?5 SO. FT. GREELEY, CO. 80634 1601 37rh STREET P.IGOEN FARM - FILING SIX N E EVANS. CO. 80620 RMG PROJECT NO: 140438 PHONE: (970) 330-1071 FORT COLLINS. COLORADO DATE: 9/19/13 FAX: (970) 310-1252 No Text Architecture Materials Testing Structural RM r� Forensic Geotechnical Civil/Planning ROCKY MOUNTAIN GROUP Job No. 140618 September 26, 2014 City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80522 dmogen@fcgov.com Attn: Dan Mogen Re: Lots 162 thru Lots 193 Rigden Farms, Filing No. 6, Final Plat Fort Collins, Colorado Dear Dan: This letter is provided to the City of Fort Collins to discuss the drainage certifications for Lots 162 thru 193 in Rigden Farms, Filing No. 6. These lots were changed from the originally proposed attached single family dwellings to detached single family dwellings as evident by the submittal of the Site and Grading Plans to the City of Fort Collins. These lots were approved by the City of Fort Collins to be constructed as detached single family homes. The changes to the lots included detached garages and house foundations and each structure was evaluated separately to recommend the top of foundation elevation and minor adjustment to the grading elevations. The original intent of the subdivision master grading plan was followed with the lots draining as proposed in the subdivision grading plan. This was provided with each lot being designed and reviewed as a detached single family home. I hope this provides the information you have requested. Should you have questions, please feel free to contact our office. Cordially, op. REG/t �.� 9/29/14 %. 24995LF-� Thomas M. Cope, P.E. NHS%Npj .�. Professional Engineer Southern Office: Central Office: Northern Office: Monument: 719.488.2145 Colorado Springs, CO 80918 Englewood, CO 80112 Evans, CO 80620 Woodland Park: 719.687.6077 719.548.0600 303.688.9475 970.330.1071 Erbil/Kurdistan Iraq: 0750192 99 44 Ulaanbaatar, Mongolia: 976 99106671 www.rmgengineers.com