Loading...
HomeMy WebLinkAboutLot Certifications - 08/14/2014 (11)Utilities , ,., -r 4" Q electric. stormwater. wastewater. water 700 Wood St. Box580 Fort Collins Fort Collins, CO 60522 Fo s 970.221.6700 970.221.6619 fax . 970,224.6003 TDD ulililies(>fcyov.com . fcgov.corr✓utililies CERTIFICATION OF LOT GRADING Pursuant to City Code § 26544 and City Land Use Code § 3.2.2 (e) Date: August 12, 2014 Permit Application No. B1305057 rrl,obc� a/��io� Address: 2838 Denver Drive Lot: 187 Block: Subdivision: Rioden Farm — Filing Six (,(Print) Andy Paddock , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): August 12, 2014 accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): r�\ The, elevations and drainage patterns of the lot/site are insubstantial conformance with the City approved / -- drainage and grading plan for the property (information attached). SEE NOTE. ❑ The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the approved drainage plan,, and will affect stormwater drainage on and off the lot/site in a m with the approved drainage plan. SEE NOTE. By: n. I» 1601 371h Street Evans, CO 80620 (address of signing party) 37607 x NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the IoUsite, Including but not limited to drawings of the lotlsite showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written informatlonlexplanation of discrepancies, and other Information necessary to confirm the above certification to: Fort Collins Utilities 700 Wood Street Fort Collins, CO 80521 (970)221-6700 Rev. 1127/12 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property r ,. Tl3w TRiA LEGEND: G2ADE BP,EAK/SWALE: --- PROPERTY LINE : -------------- SETBACK: ------------------- EASEMENT :--------- DRiONAGE DIRECTION. lO 5' SIDE SETBACK 020' FRO14T SETBACK 2. 15' SIDE STREET SETBACK G 9' UTILITY EASEMENT C 15' REAR SETBACK; © 14' UTILITY EASEMENT 2838'DENVER'DRIVE SCALE: i" = 20'-0" i TOP OF FOUNDATION ......._...__-....._......._...__...----..........-._........................................ ': 88.70 MAX FINISH GRADE ELEV 88.03 AT FOUNDATION WALL ..............._.._------- -.......... - DRIVE SLOPE ' 7.86%. .... ................ _....... _..._......... _..................__-..._......_..........._.....-....._ FRONT GARAGE F.F. [ 88.20 7 I^' J.F A EASEMENT _..._..___..-..._.......__.._..........._..._.._---------.._._.._._ I GARAGE FLOOR ELEV. . .................... 88 62 AT ENTRY DOOR ELEV. OF FOOTING BOTTOM 85.7O 0 FRONT OF GARAGE SITE & GRADING PLAN CLIENT : JOURNEY HOMES, LLC RMG ENGINEERS PLAN TS-1652 4.575 50 FT 7251 Yi. 201h ST., BLDG. L. STE 200 GREELEY. CO: 80634 RMG 1601 371n STREET LOT 157 - Et'=b(j'O) r F.IGDEM F::RPA - FILING SIX P.MG PROJECT N0: 140405 N G I N E E R S 30-IL1 PHONE: 19D1 330-k l FORT COLLINS. COLORADO DATE: 9/19/13 FAX: (970) 330-125Z cCn'1�4 �� � .. 1i..�q�' � -4 .K':W `j + _�.. _ J •+ Architecture Materials Testing Structural R MG Forensic Geotechnical Civil/Planning ROCKY MOUNTAIN GROUP Job No. 140618 September 26, 2014 City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80522 dmogen@fcgov.com Attn: Dan Mogen Re: Lots 162 thru Lots 193 Rigden Farms, Filing No. 6, Final Plat Fort Collins, Colorado Dear Dan: This letter is provided to the City of Fort Collins to discuss the drainage certifications for Lots 162 thru 193 in Rigden Farms, Filing No. 6. These lots were changed from the originally proposed attached single family dwellings to detached single family dwellings as evident by the submittal of the Site and Grading Plans to the City of Fort Collins. These lots were approved by the City of Fort Collins to be constructed as detached single family homes. The changes to the lots included detached garages and house foundations and each structure was evaluated separately to recommend the top of foundation elevation and minor adjustment to the grading elevations. The original intent of the subdivision master grading plan was followed with the lots draining as proposed in the subdivision grading plan. This was provided with each lot being designed and reviewed as a detached single family home. I hope this provides the information you have requested. Should you have questions, please feel free to contact our office. Cordially, Thomas M. Cope, P.E. us�OtVAI E� Professional Engineer Southern Orrice: Central Orrice: Northern Orrice: Monument: 719.488.2145 Colorado Springs, CO 80918 Englewood, CO 80112 Evans, CO 80620 Woodland Park 719.687.6077 719.548.0600 303.688.9475 970.330.1071 ErbWKurdistan Iraq: 0750 192 99 44 Ulaanbaatar, Mongolia: 976 99106671 www.rmgengineers.com