Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Lot Certifications - 08/14/2014 (13)
Utilities electric. stormwaler. wastewater. water �ort 700 Wood St. PO Box 580 Colli ns Fort Collins, CO 60522 �M s 970.221.6700 970.221.6619 fax . 970.224.6003 TDD utilities@fcgov. com • fctlov.com/utilities CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: August 12, 2014 NFL Permit Application No. co fAw6 dj Address: 2862 Breton Way C Lot: 159 Block: Subdivision: Rigden Farm — Filing Six (,(Print) Andy Paddock , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwaler facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): August 12, 2014 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. o The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the approved drainage plan, and will affect stormwater drainage on and off the Iot/site in a in with the approved drainage plan. SEE NOTE. By: j s 607 z (signature, PE stamp)�A: OX 1601 370" Street. Evans. CO 80620 ...... (address of signing party)T� NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the lot/site, including but not limited to drawings of the lotisite showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written informationtexplanation of discrepancies, and other Information necessary to confirm the above certification to: Fort Collins Utilities 700 Wood Street Fort Collins, CO 80521 (970) 221-6700 Rev. 1127112 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property CH - 2uw JOSEPH DRIVE 18rT -1-bV - 9) .7s LEGEND �VVa wl%�I Vn^nn.I GRADE BREWSWALE: SCALE: I' - 20'-0' PROPERTY LINE : - TOP "OF FOUNDATION !• 90:80 ---- SETBACK: --------------- IMAX FINISH GRADE ELEV 190.13 EASEMENT: ------------- AT FOUNDATION WALL DRAINAGE DIRECTION: .i DRIVE SLOPE I 7.33X FRONT GARAGE F.F. 190.30 OI 5' SIDE SETBACK W FRONT SETBACK O7 IS' J.P.A. EASEMENT' 1 ! GARAGE FLOOR ELEV. O2 15' SIDE STREET SETBACK O 15' UTILITY EASEMENT © 9' UTILITY EASEMENT !i AT ENTRY DOOR 90.72 0 6' REAR SETBACK © V U a D EASEMENT ELEV. OF FOOTING BOTTOM I 87.80 • FRONT OF GARAGE SITE 8t GRADING PLAN CLIENT PLAN TS-1433 JOURNEY-HOMES,LLC RMG ENGINEERS 7251 W. 20th ST:;`BLOGa"c-STE. 200 LOT 159 - J;925 SO. FT. GREELEY,-CO. 80634 1601371h STREET RIGDEN FARM` 'fICING SIX ' RMG PROJECT NO:140465 EVANS, CO. 80620 N PHONE: (970) 330-1071 FORT COLLINS. COLORADO REV DATE: 2/4/14 FAX: (970) 330-1252 No Text