Loading...
HomeMy WebLinkAboutLot Certifications - 04/07/2014 (36)v City of F6rt Collins Utilities electric. stormwater. wastewater. water 700 Wood St: PO Box 580 Fort Collins; CO 80522 970.221.6700 970.221.6619 fax . 970.224.6003 TDD utilities@fcgov.com . fcgov.com/utifities CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: April 4, 2014 �.l�s� 41.7 11+ Permit Application No, IM-W.0" Address: 3098 Denver Drive Lot: 132 Block: Subdivision: Rigden farm- Filing Six I,(Print) Tom Cope a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed 'from a survey performed on (Date): April 4, 2014 , accurately and truly:depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, 1 certify that (check,one): The elevations and drainage patterns of the Iottsfte are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. o The elevations and drainage patterns of the lottsite as measured are in general conformance with the City approved. drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the spec ,RW,rruip� �� approved drainage plan, and will affect stormwater drainage on and off the lottsite in a mg!, r%qlkft With the approved drainage plan. SEE NOTE; O� �oMaS M Q (signature, PE stam J (address of signing NOTE: A COMPLETE certification must be submitted at least two weeks prior to -a request for a Certificate of Occupancy for the Iotisite, including but not limited to drawings of the lot/site showing the approved design and as -built surveyed elevations of allstructures, drainage and grading features (e.g. swales, retaining walls, lot corners), written information/explanation of discrepancies, and other Information necessary to confirm the,above certification to: Fort Collins Utilities 760 Wood Street Fort Collins, CO 80621 (970) 221-6700 Rev..127U12 At least Two Weeks Prior To Requesting A Certification Of Occupancy Foe The Property o +�'� 34'-3� • io I V `O 83.80 �6�i.1b 4 �' H.P M.W T 84.6 25'-ply 81008'11" wP'.t70 2• �N 31 0.70 ° ° r � 83.70 �' � i � - � � '• • � � - . 9.33' I r I / 1 .r 34'—,bi• a. N Q ®' 21.67' V w ; 1 I N' � r i n 205, 3.63' N I / 0.5 ro / " o (U 8.17 /�, /. // N / I N c� 40' 1 8 33'6, N ". 3 / �N $ B?3"/p In/ 3 `Svc / r a a S�. 060j, 5 �Z 80.00 16 LEGEND �b y 3098 DENVER DRIVE GRADE BREAK/SWALE: SCALE: I" = 20'-0" PROPERTY LINE : — — - — - — —=--- — — - — - — ;TOP OF FOUNDATION 66.25 __........_.._......___........_.............._.._.........._........_.._.....E_........_........... SETBACK: -------------------------- - MAX FINISH GRADE ELEV EASEMENT: ----------- AT FOUNDATION WALL 85.58 -- I.._.........._ .............._........_.. __...._ .... _.............................I. .......... _...... _. DRAINAGE DIRECTION : > !DRIVE SLOPE 16.00% ....... :FRONT GARAGE F F 185.75 ID 5' SIDE SETBACK_................_................_......_...._.<.......... __........ . ® 15' FRONT SETBACK O7 15' J.P.A. EASEMENT I'GARAGE FLOOR ELEV. 0 15' SIDE STREET SETBACK O 9' UTILITY EASEMENT 1 AT ENTRY DOOR 1 86.17 O3 8' REAR SETBACK © 5' U 8 D EASEMENT 1 ELEV. OF FOOTING BOTTOM 183.25 is ® FRONT OF GARAGE SITE & GRADING PLAN CLIENT: PLAN # SL-2242 J 8 J CONSTRUCTION OF NORTHERN COLO. RMG ENGINEERS 7251 W. 201h ST., BLDG. L, STE. 200 1. LOT 132 - 6,177 S0. FT. GREELEY, CO. 80634 1601 371h STREET RIGDEN FARM - FILING SIX N G I N E E R s EVANS, CO. 80620 RMG PROJECT NO: 141587 PHONE: (970) 330-1071 FORT COLLINS, COLORADO DATE: 12/18/13 FAX: (970) 330-1252 t