CERTIFICATION OF LOT GRADING
Pursuant to City Code § 26-544 and City Land Use Code § 3.3.2 (e)
Date: May 15, 2015
Permit Application No. 13KOr4.82-) CD rJcus.l+ y/,q�ur
Address: 4809 Prairie Vista Drive IS _,
Lot: 13 Block:
Subdivision: Harmony Ridge Filing 2
(,(Print) Kevin E. Forbes , a Colorado registered professional engineer, verify that the
above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately
qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading
is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed
from a survey performed on (Date): May 12, 2015 , accurately and truly depict the elevations and drainage
patterns as they existed on the date of the survey. Based on this information, I certify that (check one):
to The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved
drainage and grading plan for the property (information attached). SEE NOTE.
❑ The elevations and drainage patterns of the IoUsite as measured are in general conformance with the City
approved drainage plan with exceptions (information attached). In my professional judgment the elevations
and grading of the lotisite as constructed are functionally adequate and equivalent to the specifically
approved drainage plan, and will affect stormwater drainage on and off the IoUsite in a manner consistent
with the ap plan. SEE NOT
.......... s� B
9^' y
E. F0,� % (signature)
Kevin E. Forbes
�p
ti 5 204 N. Link Lane, Unit A-8, Fort Collins, CO 80524
(address of signing party)
o,, o kevinforbes@frii.com 970-482-9331
�rVA (email address and telephone number)
PE Stamp
NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the IoUsite, including but not limited to drawings of the IoUsite showing the approved design and as -built surveyed
elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written
information/explanation of discrepancies, and other information necessary to confirm the above certification to:
Fort Collins Utilities
700 Wood Street
Fort Collins, CO 80521
(970)221-6700
Rev. -( 3W014 Submit Two Weeks Prior To Requesting A Certification Of Occupancy For The Property
s.
"AS -BUILT GRADING
LOT 13, HARMONY RIDGE FILING 2
4809 PRAIRIE VISTA DRIVE, FORT COLLINS, COLORADO
e
SCALE. 1$$ - 20'
e
J \ e
OR- Qi� �• \ J1
.e e
d frome t
one StoN 000
21.z hose t basemen
w wi
th w '
!� b �a � �
'fie. •� ' / /
DO. REG/.s
',T
v: • 6
265
• ��s ice:•
NA%
.•
Ssro__
prepared by Stewart & Associates, Inc.
3R
\
SET CORNER AT 1'
OF SIDEYARD SETBAI
GARAGE
33.8
POR -AI\u aLIUA�m \ 32.7
r
MIN. MAIN F.F. ./ 32
L 5r HOME ELEVATION 35.63 r //
FOUNDATION LINE r 0001
UPPER DECK EXTENDS
TWO FEET FROM
14, SETBACK LINE O
�s
9
j9
r
\ / / ALL AT 1' PLUS MINUS
V .c OFF SETBACK LINE
?1.5
DRAINAGE ARROW
20.8
LOT 13, HARMONY RIDGE, FILING 2
SCALE: I" . 20' W.O. 13162/14121
RICHMOND ASSOCIATES
Architects / Planners
SITE FLAN
V�.
IMPROVEMENT LOCATION CERTIFICATE
LOT 13, HARMONY RIDGE FILING 2
4809 PRAIRIE VISTA DRIVE, FORT COLLINS, COLORADO
SCALE. 1$# = 20'
DESCRIPTION:
13, Harmony Ridge Filing 2
Collins, Colorado
RNA
a�a
�o�o�cre;g�.
,Iti p�eG �cP
kpJoe •�.
LOCAnoN CER71AAWE-
hereby certify that this improvement location certificate was prepared for Philgreen Construction,
?at it is not a land survey plat or improvement survey plat, and that it is not to be relied upon for the
stablishment of fence, building or other future improvement lines.