HomeMy WebLinkAboutLot Certifications - 11/29/2001 (2)SCOTT, COX & ASSOCIATES, INC. consulting engineers do 00 OVERLOT GRADING OBSERVATION SCA Whit CLIErT:::ZI-W t>J DATE: —401 LEGAL: rNSP. BY: GRADING PLAN: ACSOnIS Ar p Asspc, Avg Z j v O S G P•nJ DAgn Z -4-9+ We have measured relative elevations at the above mentioned location. The. observed elevations were compared to the Grading Plan referenced above. During our observations our representative measured the relative elevations at the lot sides and corners, top of foundation, and lowest openings. Based upon our findings it is our opinion: o The elevations as measured are in general conformance with the above noted Grading Plan. i- J The elevations as measured are in general conformance with the above noted Grading Plan with the following It is our opinion these exceptions, noted above, should not adversely change the grading scheme as shown on the above referenced plan. During our observations our representative noted that the as measured elevations do not conform to those indicated on the above referenced grading plan. However, it is ouropinion the grades as measured should provide an adequate substitute to the above referenced grading scheme. See the attached "As -Built" grading plan. a The elevations measured are not in conformance to the above referenced grading plan. Deficiencies include: Other comments and/or observations: Limitations It is our opinion that the subject lot, as graded on the above date, should not interfere with offsite flows unless the grades are changed or barriers are created such as fences, garden terracing, sidewalks, and/or any landscaping which may change the established flow patterns by diverting or slowing runoff Flow. Backfill adjacent to the residence may settle over time and allow ponding to occur undation walls. The backfill adjacent to the residence must be monitored and maintained to ensure th t av from the foundation. The grades measured were compared only to the requirements shown gv frr� ing plan. Other minimum grading requirements which may be specified in the soils report or �• ents are beyond the scope of this report. Rev iewed b gigDate: t :°boq�}te5treet. iwte D: Lid .Colorado 905;H o oifice5 n - 3o,ddrr • :unennna - Lmeland No Text NORTF ELEVATIC 2g (5x 22.4 (B.O.W.) AS -BUILT GRADING ELEVATIONS THE ELEYATIgL9 BHOUN MEfE GN ARE 9A0ED as THE wRver PErraaieo a+ n•n•®i TBM-I= TEMPORARY BENCH MARK M B.O.W.= BACK OF WALK LW$T= LOWEST OPENING (TOP OF WIN. WELL) BILL- BOTTOM OF WINDOW GLA56 WLKOUT= BOTTOM OF WALKOUT DOOR T.OF = TOP OF FOUNDATION = MISSING EXTENSION • = MISSIN6, DOWNSPOUT -1 w O N z� 0V its)0I z 00 JOB NO. 1161-15-1-6 Dxft� 11/29/01 SCALE 1'=30' DRAWN, RLG CHECKED CPH L_L. Q SHEET NO.t 1 OF I