Loading...
HomeMy WebLinkAboutLot Certifications - 07/18/2000SCri-TT, COX & ASSOCIATES, INC. consulting engineers Jttly 14.2000 STQRAtnl" ,, ; Savant Homes. Inc. Alan Strope O) JUL 1 7 M 3320 Hearthfire Drive Fort Collins. Colorado 80524 Project No. 4612-04-01-07 Gentlemen: We have measured the relative elevations for the over lot grading at Lot 77, Greenstone P.U.D. Phase 3, (1631 Streamside Court):Fort Collins, Colorado. During the investigation, we measured elevations at the lot sides and corners, top of foundation, lowest opening, and the drainage swales on the north and south sides of the subject lot. Our representative noted that the swales on the north and south sides of the subject lot allowed runoff flow to reach the sidewalks, east of the subject lot. The lots to the north and south of the subject lot (Lots 78 and 76) were unoccupied at the time of our observations. However, our representative noted that the grades at the west (rear) side of the subject residence were very minimal especially in the vicinity of the northwest portion of the subject residence. Based on our observations, and the information available to this office, the slopes and elevations as measured and with the above noted exceptions, are in general conformance with the intent of the Drainage Plan completed by Parsons & Associates, Job Number 92.18.05-GRN, dated February 7, 1994. Please refer to the attached copies of the As -Built Grade Elevations and Drainage Plan for further information. Furthermore. it is our opinion that the subject lot, as graded, should not interfere with offsite flows unless the grades are changed or barriers are created such as fences, garden terracing, sidewalks and/or any landscaping which may change the established flow patterns by diverting or slowing runoff flow. Backfill adjacent to the residence tnav settle over time and allow ponding to occur around the foundation walls. The backfill adjacent to the residence must be monitored and maintained by the homeowner to ensure that runoff will flow away from the foundation. Thank you for consulting with us on this phase of the project. If you have any questions, please feel free to call. Sincerely. SCOTT, COX & ASSOCIATES Reviewed by: Cliff d P. aln. S. Environmental Special) t I:: CI'ECtiS%CI-I FF,GRA DING\Savant\4612-4-1-7.�vpd ;110 Granite Street, Suite D • Loveland , Colorado 80538 • (9701 663-0138 • Fax: (970) 663-1660 Serving Colorado with offices in • Boulder • Longmont • Loveland SCOTT, COX & ASSOCIATES, INC. consulting engineers July 14, 2000 Lot 77. Greenstone P.U.D. 1631 Streamside Court Fort Collins Colorado Project Number: 4612-04-01-07 Per your request, we have measured the relative elevations of your site for the purpose of comparing the as -built final grade elevations to those specified on the master grading plan for the subdivision. While the observed as -built elevations were in general conformance with the intent of the recommended grading scheme for the subdivision, the ground slopes and elevations may not conform to the grading recommendations outlined in the soils investigation for this property. Furthermore, our representative noted that the grades at the west (rear) side of the subject residence were very minimal especially in the vicinity of the northwest portion of the subject residence. For further information, see SCOTT, COX & ASSOCIATES letter, Job Number: 4612-04-01-07, dated, July 14, 2000. We are bringing this to your attention because your property has been identified as being in an area of potentially expansive soils. Providing good drainage away from structures is very important in these areas. If you would like us to address grading issues in the context of the soils investigation recommendations for this property please contact us. Respectfully, SCOTT, COX & ASSOCIATES, INC. C r P. am Environmental Sp cialist F'\Techs.Clift\Grading\ SavanL\4612-4-1-7g5.wpd I 10 Granite Street, Suite D • Loveland , Colorado 80538 • (970) 663-0138 • fax: (970) 663-1660 serving Colorado with offices in • Boulder • Longmont • Loveland z a X H e 3 I ~ o � y lu U 3 m � 4 ` cp n � Q s Q • a •0 0 n M1 LIJ M1 � In Q Q M1 n W o <3 n n M1. 0 0 O i a n r r LL r 0 a 0 „• 3 0 S Ln I n M1 O c r1 f •n i n d1 r3 M~ V O r n 9J N �• M1 n..c ry Z N K n X •p z W Z Q F ^ � - m N• � � O V r U a r a �o a J OLL LL 1 U �^ Z � p w cp a Q Z `, • u dam J p mo0 W W 67 p t X ^ o 0 W U °a $ r u � o 0 In 0 = r A Q M 0 w � w WIS-7 z � w z O c) :� W w W — > 0 1 j F- N J w I j wWj IQ�ae 0 w O �Lu=a Z W OFF Wes.<�•o �V ar N_ o TRACT �` \ - ks _ 0' DRANAC� EASEMENT 7.6 _ (TYPIC.AL) 7 7 r— 2 T`'P E T _+�` PROFILE C •;N „� ' -ram 4' CURB - I .� INLET - - - n RIPRAP _ T M %T d50=1 SANiT,jRY 8' OR'AtNAGE - - SE WER ' 7