CERTIFICATION OF LOT GRADING
Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e)
Date: May 8, 2015
Permit Application No. B1400816
Address: 5851 Dripping Rock Lane, Bldg. C
Lot:
Block:
Subdivision: Fossil Lake 4th Filing, 1st Replat
�ZSCo Asaao-Jc Co
OMM( W., b,Ja A. Sid •�.,r,s1(� L1.,c Sa .,e� I
(,(Print) Nicholas W. Haws , a Colorado registered professional engineer, verify that the
above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately
qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading
is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed
from a survey performed on (Date): 01.13.15 through 04.29.15 , accurately and truly depict the elevations and
drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one):
❑ The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved
drainage and grading plan for the property (information attached). SEE NOTE.
The elevations and drainage patterns of the lot/site as measured are in general conformance with the City
approved drainage plan with exceptions (information attached). In my professional judgment the elevations
and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved
drainage plan, and will affect stormwater drainage on and off the lot/site in a manner consistent with the
approved drainage plan. SEE NOTE.
ENGINEER'S COMMEN
IN MY PROFESSIONAL OPINION, THIS PROJECT
INHERITED A DEFICIENT GRADING AND DRAINAGE PLAN.
STRICT CONFORMANCE TO THE APPROVED PLAN
WOULD HAVE RESULTED IN ADVERSE DRAINAGE
CONDITIONS. THE CONTRACTOR MADE REASONABLE
ATTEMPTS TO IMPROVE THE DRAINAGE CONDITION. I
CONCUR THAT SAID EFFORTS IMPROVED THE
SITUATION, BUT I CANNOT ATTEST THAT SUCH
MEASURES HAVE FULLY OVERCOME THE INHERITED By:
DES14N. THIS CERTIFICATION IS STRICTLY LIMITED TO
THE PRESENTATOIN OF DATA CONTAINED HEREIN. I
TAKE NO RESPONSIBILITY AND ASSUME NO LIABILITY
ASSOCIATED WITH ANY SHORTCOMINGS OF THE
ORIGINAL DESIGN.
05
05.08.25
301 N. Howes St., Suite 100 180521
(address of signing party)
NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the IoVsite,
including but not limited to drawings of the lollsite showing the approved design and as -built surveyed elevations of all structures,
drainage and grading features (e.g. swales, retaining walls, lot corners), written informationlexplanation of discrepancies, and other
Information necessary to confirm the above certification to:
Fort Collins Utilities (970) 221.6700
700 Wood Street
Fort Collins, CO 80521
At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property
Rev. 2009
wtaso�e w
ewuwoee wn
wn 4°..0�� awwn�a0
�'
_
x i eo ,.�u
_ �
n t wuu..0
�
NVId ONIOVtlO
lYld3!! 19l6i 'ONlId HiFlf10A
n
-
-
to
t
P JDIS I
mlS p1tiN
�1..
_.
—
-- —
a
�,.vau °ems
'dQd 3NY7'tl980A
Y
Ii
la
'
:7
:
F
'
C
-
1
5
i
7apq.
In 5�
I
pp
Q
OCT
e
• �e
F•K
�
'
�
— OVOtl
tl3TJ31Z
ENGINEER'S NOTES:
- AN ADDITIONAL SIDEWALK CONNECTION (AND CORRESPONDING CHASE) FROM THE UNIT PATIOS WEST TO ZIE4LER RD. WAS INSTALLED.
- AN ADDITIONAL SIDEWALK CHASE ALON4 THE NORTHERN PATIOS WAS INSTALLED TO FACILITATE DRAINAGE CONVEYANCE.
- AN ADDITIONAL CURB CUT TO THE NORTHEAST' OF THE BUILDIN4 WAS INSTALLED TO FACILITATE DRAINA4E CONVEYANCE.
- 4UTTERS/DOWNSPOUTS HAVE BEEN PIPED TO HELP DIRECT ROOF RUNOFF AWAY FROM THE BUILDIN4.
e.e.«w wrmam�awcamwpmam� com •sewcq�x n.u.an. iaemu ramwx. i nsm
m