Loading...
HomeMy WebLinkAboutLot Certifications - 10/16/2013 (2)W,luud ar, iv-31-13 L)m Utilities Ci,oelectric. stortnwater. wastewater. wafer Fon.Coltins Fort Coffins, CO 80522 / Vy� ST02M.6700 970.221.6619 fax • 970.224.6003 TDD uffhges@fcgovcom . fogovcorrdu67f6es CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2•Y (a) Date: 10 _I (o) 3 Permit Applicatiori No. 131'5 0 1803 Address: C:jA&& F SAe4^rc, rat. Lot Block: Subdivisio„ L-Att, r— 2 I,(Print) J ASo+.1 )=• 17AK.ElL. , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stomhwater facilities and grading is complete, and that the elevations and drains a patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): O ) accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the lousite are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. )v The elevations and drainage patterns of the Iottsite as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my the elevations. and grading of the lot/site as constructed are functionally adequate a e of t {3Ifig7s Ily approved drainage plan, and will affect stormwater drainage on and tit npT stent with the approved drainage plan. SEE NOTE. "CAD1T8�� I ��i-o2- otF U , 9 DaT lo�tt f �> 39 By: 0 (address NOTE A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the lotfsite, including but not Itrnited to drawings of the tot/srte stowing the approved design and as-bulit surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining waits, lot comers), written irdonnatiordexplanation of discrepancies, and other information necessary to confirm the above certification to: Fort Collins Utilities 700 Wood Street Fort Collins, CO 80521 (970) 221-0700 Rev. f27f12 Submit Two Weeks Prior To Requesting A Certification Of Occupancy For The Property ADVANCED ENGINEERING, LLC STRUCTURAL DRAINAGE DR&MNS OVERLOT GRADING OBSERVATION Site Observation Date: Io4IT_ Advanced Engineering, LLC Ppoject Number: Site Observation by. _ Client Name: Loxv Az-f LknzA Cw- ,,{o • Co. Site Address: 11 De rvo- . SiteLegal: Lou 5 Pr.:►oa. a9. D. Site Plan and/or Grading Plan by l�/ce�1-tf�! EGA 5./cs t SFE ` oZ-o�l e+o D --a t 10 We have observed portions of the above referenced site. During our observations our representative measured the relative elevations at the lot sides and corners, top of foundation, and lowest openings. The observed elevations were compared to the Site Plan and/or Grading Plan referenced above. Based upon our findings it is our opinion drat•: ❑ The elevations as measured are in general conformance with the above noted Site Plan and/or Grading Plan. ❑ The elevations as measured are in general conformance with the above noted Site Plan and/or Grading Plan with the following exceptions: It is our opinion these exceptions, as noted above, should not adversely change the grading scheme as shown on the above referenced plan. * Duffing our observations ourrepresentative noted that the as measured elevations do not conform to those indicated on the above referenced Site Plan and/or Grading Plan. However, it is our opinion the grades as measured should provide an adequate substitute to the above referenced grading scheme (see comments below). * Seethe attached -As-Built"grading plan. ❑ The elevations measured are not in conformance to the above referenced Site Plan and/or Grading Plan. Deficiencies include: Other comments and/or observations: © op t o.3' t e M i E o. ' Ks+ ® rho �2 fo2� o MON. (.ANOSc Limitations: It is our opinion the above referenced site, as graded on the observation date, should not interfere with offsite flows unless the grades are changed or barriers are created such as fences, garden terracing, sidewalks, and/or any landscaping which may change the established flow patterns by diverting or slowing runoff flow. Backfill adjacent to the residence may settle over time, this settlement may allow ponding to occur adjacent to the foundation walls. To prevent this ponding and related problems, the backfill adjacent to the residence must be monitored and maintamedto ensure that nmoffwill flow away from the foundation. The grades measured were compared only tothe re own on the above referenced site plan and/or grading plan. Other minimum grading requirement which may, a report or by other construction documents are beyond the scope of this report �P • N.E. B• /'STcc �G Reviewed by: Jason E. Baker, P.E. /`33739 146 Barberry Place, Loveland, Telephone 970-278-1909 - Fax 970-278-1910 "A5-5UILT" OVERLOT GRADING 05SERVAT IONS LOT 15 SWIFT ADDITION TO FOSSIL LAKE P.U.D. 86A HP 86.5 WW1. 811 85.9 8b3 (B.OW1J p�yE g TF. = 815 .a DOOR 0 Crb.33 < t9 812 GREEN P SPRING DRIVE 83B 813 (B.O.WJ _ LI Sab U De E 83B 84.9 CBAWIJ HI 85.1. 84-1 ct- 319 LEGEND: TOFF. = TOP OF FINISHED FLOOR TF. = TOP OF FOUNDATION. W.W. = TOP OF WINDOW WELL B.O.W. = BACK OF SIDEWALK B.O.C.lG. = BACK OF CURB 4 GUTTER T.5M.-1 = TEMPORARY BENCHMARK I H.P. = HIGH POINT OF SWALE XQ = SEE ADVANCED LETTER 1111-02-1OF DATED 10-11-13 w.W.1 86.0 W.W. 86.0 -82.1 evaa raoieVA�xxT n'ae�e: 171-�-'°� ADVANCED Luxury Homes of N. CO IOn;n3 31Y6 Green Spring Dr, Ft. Collins, Colorado I6CA1=20 ENGINEERING, LLC STRUCTURAL DRAINAGE DRAFTING C4=14 146 B"BERW PL 9. LOKLANU, COLD 00 80537 TELEPHONE 970-276-1909 �4 is i ttc , OZ-COC>.oa ►�a�� VC)103