Loading...
HomeMy WebLinkAboutLot Certifications - 06/15/2006JUN-14-2006 07:19 FROM: TO:2216619 P.2 City of Fort Collins Date: 05/04/06 Utilities electric • stormwater a wastewater a water CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Permit Application No. Ao.VAP%� 40 Address: 3609 Rocky Stream Drive 011 Lot: 49 Block: b -4A Subdivision: Swift Addition at Fossil Lake L° STORMWATER RECEIVED JUN 1 4 2006 (,(Print) Wyatt M. Knutson . a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or someone under my direct supervision, and verify construction of all stormwater facilities and grading is complete, and the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date) 05/04/06 accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. w3 The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot as constructed is functionally adequate and will allow for stormwater drainage consistent with the approved drainage SEE NOTE. o�p00 M K*Hli�;.LiP By: 38106 (sictnat e, PE s M) (address NOTE: A COMPLETE certification must be submitted, Including but not limited to drawings of the lotlsite showing the approved design and as -bunt surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written Informatiordexplanation of discrepancies, etc. to: Fort Collins Utilities (970) 221-6700 700 Wood Street Fort Collins, CO 80521 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property. Rev. 1111106 JUN-14-2006 07:19 FROM: TO:2216619 P.3 Final Grade Assurance Observation: Per the clients request, a representative of SECURE has visually observed and measured elevations of the grading around the home at the site referenced below. The following summarizes our observations and opinions at the time of our visit. SECURE CONSULTING ENGINEERS A CTL (_THOMPSON COMPANY Client: ♦ Site Address: 36A9 A.-.4L Pn Aek 2-705_R For} Secure Job#: 4EODW7 Lot: *1 Block: • Filing: - Date: 05/n4/DG, Contact: Tony Subdivision: SthI Adel lfion Background Information: Referenced Grading Plan: Northern Entm n Dated: 01/10/03 Job#: 02 M.00 S Measurement Elevation Remarks 1 0.004 4881.73 2 -0-11 ft 4 881.62 3 _ t.25 4 - tt 5 -0.84 fE 4880.09 6 - 0.9 6 ft 4 _77 7 - 1.19 f b 488054 g 0.92 11 ABA7.65 9 I.80 Ft 4883,68 to 2-99 ft 14884.12 11 3.01 ft 4e 4.74 12 1.30fE .03 13 1.45 Ft 4883.18 14 -0.40 FE 4 1.33 15 3.75 Ft 4885.49 16 3.G7 St 14BB5.40 17 3. it fle 14 18 , 41;t 19 9.58 ft 4 5.31 20 3.7 8 Q 4885.51 21 3.60 22 3.59 fa 32- 23 -1.33 N 4883-06 24 3. %3 fN 1AN4.8G more Stai►ons on page? site: EA r r t 1 • t . Summary of opinions: It is our opinion that the top of foundation and grades around the home are consistent with the above referenced grading plan or are a functionally adequate substitute. 0 Rejected (2"d observation required) Corrective action: 0 A A� 05m4/Oro FieldlRepresatative Date Secure Foundations, LLC • 211 West Magnolia Street, Ft. Collins, CO 80521 • Ph: 970472-6255 9 Fax: 970472-6256 JUN-14-2006 07:19 FROM: TO:2216619 P.4 Final Grade Assurance Observation: SECURE Per the clients request, a representative of SECURE has visually observed and CONSULTING ENGINEERS measured elevations of the grading around the home at the site referenced below. ' i The following summarizes our observations and opinions at the time of our visit. A CTL 1 THOMPSON COMPANY '.t Client: S Same Site Address: S Arne Secure Job#: Lot: Block: Filing: Date: Contact: Subdivision: Backeround Information: Referenced Grading Plan: Dated: Job#: STA Measurement Elevation Remar 35 G.15124 4888.79 Vloor 26 1.19 VA 4883.52 27 1. 3Z fF 65.05 28 0.1 ft 251 1-14 ft 4982--87 0 2.68 ft 4684.11 31 1.22ft 489L95 32 -0.03 ft 48SV70 33 0.26 ft 48809 311 0.56 ft 2.2 5 0.67 ft 4882AO 36 0.20 Ft 4881.93 37 0.18 ft- 48 38 anG ft4 1.7 39 0.04 ft 48SI.77 40 0.53 ft 48ALIG 4t Toc, of Watt 42 - -91 ft 52. 3 1.51 fE 4883.24 44 1.0 8 4 4882.81 45 i-Qft 4982.86 E 48 Z.92 - 0.48ft 46BI.ZS -0.98ft 4880.75 Site: G a+tached . j. � .. STA Measurmert EleVallOn Remarks 49 -1.12 Pt 52 _�--- --- 50 _ - 1,15 f t o.5 t - D9 ft 52 -0.90 fi; ace Secure Foundations, LLC • 211 West Magnolia Street, Ft. Collins, CO 80521 • Ph: 970472-6255 • Fax: 970472-6256 T0:2216619 P.5 46 AA STORMWATE RECEIVED JUN 1 4 2006 JUN-14-2006 07:20 FROM: BLOCK 4 I Ies 52 i4 I I FG-83.78 I� TF=84.45 III O � ,� 83 KY STR _ D _ E TO:2216619 P.6 \ \ S FG=87.37 / TF=88.04 \ O i i3 10, A M.48 / 16.15 i 8 / � I I i 82 _ 48 �. FG-83.07 49 I T $5.69 TF=83.74 FG-84.35 © I TF=85.02 I BLOC 'P 80 ap o �e ---