HomeMy WebLinkAboutLot Certifications - 10/26/2006 (2)OCT-23-2006 15:47 FROM:
TO:2216619 P.2
City of Fort Collins
Utilities
electric • stormwater • wastewater . water
CERTIFICATION OF LOT GRADING STORM ER
Pursuant to City Code § 26-544 and RECEIVVEE D
City Land Use Code § 3.2.2 (e) OCT 2 3 2006
Date: 10/23/06
Permit Application No. B060198
Address: 6039 Wild View Drive
Lot: 31 Block:
Subdivision: Swift Addition at Fossil Lake
(,(Print) Wyatt M. Knutson , a Colorado registered professional
engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been
inspected by me or someone under my direct supervision, and verify construction of all stormwater
facilities and grading is complete, and the elevations and drainage patterns shown on the attached
drawing(s) which were developed from a survey performed on (Date) 10/23/06
accurately and truly depict the elevations and drainage patterns as they existed on the date of the
survey. Based on this information, 1 certify that (check one):
❑ The elevations and drainage patterns of the lot/site are in substantial conformance with the City
approved drainage and grading plan for the property (information attached). SEE NOTE.
❑ The elevations and drainage patterns of the IoUsite as measured are in general conformance with
the City approved drainage plan with exceptions (information attached). In my professional
judgment the elevations and grading of the lot as constructed is functionally adequate and will
allow for stormwater drainage consistent with the approved drain 0�
SEE NOTE. o�� � M Ktii 'ip
JO:, o
38108 Z'
By:
(sianat . PE D)
(address of signing
NOTE:
A COMPLETE certification must be submitted, Including but not limited to drawings of the IoUsite showing the approved design and
as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written
information/explanation of discrepancies, ate. to:
Fort Collins Utilities (970) 221.6700
700 Wood Street
Fort Collins, CO 80621
At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property
Rev. 111106
'Q' JQ- Jb
DCT-23-2006 15:48 FROM:
T0:2216619 P.3
Final Grade Assurance Observation:
Per the dicnt. request. a representatite of SEC IIRL• has visually observed and
mw>urcd cle%attnns of the grading around the home at the site referenced below.
I he lidlooing smnmarizes our ob%ery tit ions and opinions at the time of our visit
SECURE
CONSULTING ENGINEERS
V A CTL 1 THOMPSON COMPANY
Client: Brannen Design •I-00n9+rticfian Site Address: G039 Wild Vie%A, Dr_
PO. Box 27a57A Vp 4 re) liriS,CO.
Secure Job#: 9F01//2 Lot: 31 Block: - Filing:
Date: loaS/oa Contact:�_T rannen Subdivision:&6�'t Arlc/tt►on Fend
Background Information:
Referenced Grading Plan: Northern Entaineerlr7Q
5ervices,Inc
Dated: 0t/I10/03 _ Job#: SEE-'02-&Oqf-30_
SIA
Measurement
Elevation
Remarks
1
0.00
84.01
+0.7-1
84.2Z
• 3.57
87.58
4
+q.49
88.50
+ 3. 51
87.52
6
+4.71
88.72
7
r5.90
89.g1
slab
8
+5.92
89,93
slab
9
+2 94
86.95
10
+2.32
86. 33
11
+5.09
89,10
12
+5.21
8q, 22
13
+5.98
89.99
Slab
14
42.74
8ro75
15
+0.68
84,69
16
+ 2.2 2
8G, 23
17
+4.5G
88.57
18
4,9.59
93.G
finiShCd floor
19
+5.44
89,45
20
+4.8G
88 87
21
+2.lq
8G.20
"-
0.00
84.01
23
40.41
8q.42
24
+ 0.88
84.89
Site:
Summary of opinions:
15 It is our opinion that the top of foundation and grades
around the home are consistent with the above
referenced grading plan or are a functionally adequate
substitute.
0 Rejected (2nd observation required)
Corrective action:
Secure Foundations. LLC • 211 West Magnolia Street, Fl. Collins, CO 80521 • Ph: 970-472-6255 • Fax: 970-472-6256
OCT-23-2006 15:48 FROM:
TO:2216619 PA
Final Grade Assurance Observation:
Per the clients request, a representative of SECURE has visually observed and
measured elevations of the grading around the home at the site referenced below.
The following summarizes our observations and opinions at the time of our visit.
SECURE
CONMl
SULTING ENGINEERS
A CTL I THOMPSON COMPANY
Client: Seep )L a pace Site Address: �S66 previotle paom
Secure Job#: Lot: Block: Filing:
Date: Contact: Subdivision:
Backeround Information:
Referenced Grading Plan:
Dated: Job#:
Site:
See Attached
FAT
STORMWATER
RECEIVED
OCT 2 3 2006
Secure Foundations, LLC • 211 West Magnolia Street, Ft. Collins, CO 80521 0 Ph: 970.472-6255 • Fax: 970-472-6256
OCT-23-2006 15:48 FROM:
T0:2216619 P.5
_ .9 ee . r 46
STORMWATER
RECEIVE®
OCT 2 3 2006
OCT-23-2006 15:49 FROM: TO:2216619 P.6
\ � � 28 /
34 \ FG=88.25 /
FG-90.19 TF-88.92
83. < 29
i
LP FC-86.99
coTFa8O7.66 i
33 �� h
FG=89.55
TF-90.22
83.00
w
30
1 FG=86.61
81, 8 \ o / TF=87.28
i O
P
a 86
/ Fc386.07 ti, 31 \ 11P
TF=86.74 FG=86.67
TF=87.34
O I
84
1
1 ST S
I LINE 8
STORM SEWER
-/
LINE 9
LOT 12 jf LOT 12
M O.E.= 102.7 M.O.E.= 102.7
FG= 102.7 Fc= ,02.7 STORMWATER
I Tf= 1034 I TF= 103.4 I RECEIVED
B
O,p
OCT 2 3 2006