HomeMy WebLinkAboutLot Certifications - 01/09/2003December 19, 2002
Mr. Jay Barber
Fort Collins Utilities
P.O. Box 580
Fort Collins CO. 80522
Dear Jay,
$TE vARr&A ssOCIATE$
Consulting Engineers and Surveyors
STORMWATER
RECEIVED
DEC 19 2002
- 'ctf?. rr.;. -- . .
Please find enclosed "AS BUILT" grading survey of the grading for Building L and
surrounding landscaping, Fossil Lakes P.U.D. Third Filing, which is 3450 Lost Lake Place, Fort
Collins, Colorado.
The grading is in substantial compliance with the flow directions of the grading plan
approved by the Larimer County Engineering Department on December 28, 2001. The finished
floor elevation of the building is 4902.20, which is 0.4 feet above the finished floor shown on the
grading plan. The garage finished floor elevation to the North is 4900.86, which is 0.06 feet
above the finished floor shown on the grading plan. The garage finished floor elevation to the
South is 4900.84, which is 0.91 feet above the finished floor of said grading plan. All of these
variances are OK.
The grading of the driveways is sufficient to create adequate drainage away from the
structure and channel water into the existing curb and gutter of Shallow Pond Dr. to the North,
and Lost Lake Pl. to the South. The grading of the lawn and landscaping is also adequate to
channel all water away from the building and into the curb and gutter of Shallow Pond Dr. to the
North, and Stonewater Dr. to the East.
If you have any questions regarding this certification, please call.
Sincerely,
Richard A. Rutherford P.E. & P. .S.
RAR/mgr
James H. Stewart and Associates, Inc.
103 S. Meldrum Street • P.O. Box 429 • Ft. Collins, CO 80522
970/482-9331 • Fax 970/482-9382
S.
if IN
j"Y / 11 ^r' /p/ �\ , - x / /' �•'\ •\ t
IN IN
' �'- '••�. x. �./ ! / !iVEII
.... v 'r / j$
1NIL
•.x` �•\' BLOCK 6,, • ,} !. i/'' / /,� x 'c
•�`• / /��!�'/rll % I '$' Y —x�.x x•x.��` i//,R/ l8 %�/\, -!_ _ 1 % „/ ai\.� /i,' �D
// :/ l C' !/'.��:'�r ' r /,5b/ \\'9S, '�``-�•ti`\�/A/j C ELD�
!b �` x;•j I.
\}
17 y
/iN'CI
�V 3aLL
a \ "��!E/� /
CI
Foes. uKE HUD)\�/ l• •L x< C I ,r 'i / \— 2 0
FlP9r F0.W0 / /A, I `TQ d `.,
SCALE: I' AA w'
-! _ BLOCK 13! e
is oti > ��.; o
r « ,I Fr_.ygT,ex 1r e}o ,yf•;%
/ / 0' EA WENT - 9 1 ;
4U Y,' i. % , 'ate••'
Fd RDErrAua
I
N% T 6.f.n-xecm 3 0
ID,/ I .eve \-\ x: xx 14 `
/ A �� \ -VAN
,/
'
IN A-
.p FOSSIL LAKE, P.UD Z
r Q"'�/ - .o / KYF ' ��• SECOND FLING
ut art 'F'
yyyv%
FINANIALDW -
i0 iNU1CAY H -
I O d Q V
SAN
•\\�� m
Y `
1 � t
t r e
e WS.w
\ \
IV
1,Its 0
STANDAMEN
T AE II BFIKWAr \ FFbOTY Of ONLY.
I I -
r I \ It,. \ - n x',' L COLLINS DETAIL
- _- __ - vF-4Pv..0 -- —
w4
g w
_� 7_ t .♦ / gar-.evm. [ ,3 Z
FOSSIL LAKE, AMID,I+Id •I/ / $ � LL
-� CALL UTILITY NOTIFICATION
'SJEnw< CENTER OF COLORADO
FAST --- /, / 1=800-92201987
� I 410 ,. � � � q_4yD.A !
m53I'
N _ 90EWWt - _ . BO'X. 9tOIAV 30 BEFOREx OU 4D V 70A CRAVAT LdHR
Y_ ______-. .___ -_- OR THE INca DIESAWN0 Q
_ _ _
MEMB
_ �_
IPLDIC AA
A �
as
D. _ W ae
9D...lRI.Y TO. -NOSE
1 O' IRAX eT OTwERS BONYR000S-
W i a
J
I 1 LEGEND
p TOW TOP OF WALL ELEVATION v/
dl$. BOW BOTTOM OF WALL ELEVATION O
PEER TO SAFET E FOR MA HND ON THE STREETS HP HIGH POINT LL
3. AREA TO SHEET S FOR HORIZONTAL LOCATION! OF OPIYEMAYS AID STREETS
RE FINISHED FLOOR ELEVATION
GET ELEVATION AT FRONT OF GARAGE
j
' EXISTING CONTOURS
Y - EXISTING INDEX CONTOURS
PROPOSED CONTOURS
' 4M— PROPOSED INDEX CONTOURS 3 OF 10
i-----------
PROPOSED FLOW-INE
doe No. 111-03