HomeMy WebLinkAboutLot Certifications - 06/04/2003 (7)AIRES ASSOCIATES May 28, 2.003 Mr. Jay Barber City of Fort Collins Stormwater Utility 700 Wood Street Fort Collins, Colorado 80521 STOR►w RECE VVA®ER MAY281003 V. Re: Drainage Certification for Lot 4, The Meadows at Fox Creek PUD Dear Jay, We recently surveyed Lot 4 of the Meadows at Fox Creek PUD (2402 Twin Fox Drive) to verify whether the grading met the intent of the approved grading and drainage plan. Spot elevations were checked at pertinent locations and compared to the grading plan. The enclosed drawing shows these as -built elevations. In general, the lot and building meet the requirements of the grading and drainage plan and there is positive drainage away from the building on all sides. The intended drainage patterns are met by the grading on this lot: the west side of the lot (front and rear) drains to Twin Fox Drive, and the east side of the lot (front and rear) drains to a drainag e'swale.that runs along the east property line. Theswale.is adequately constructed to meet is.intended purpose. The rear of the lot is drained to theintended location by way of drainage swales. The first floor elevation identified in the grading and drainage plan was 5106.5. However, the first floor elevation was raised to 5108.5 but does not impact the drainage of adjacent lots and provides positive gradient around the building. The ground elevation around the house varies from 5105.4 to 5106.9. The spot elevations show a minimum slope away from the house of 6.3 percent (0.5 feet over 8 feet) and adequate fall from the building to the street and the rear drainage Swale. It is my recommendation that the Certificate of Occupancy for Lot 4 be released since the Builder graded the lot to meet design drainage patterns. If you have any questions, please call. Sincerely, �(LY Owen Ayres & Associates, Inc. *0 J Batka, P.E. + O REG�"••.,, Project Engineer�1�.••`S��� v; JB:sp 0 =� 36899 '• o _ . Enclosure Owen Ayres & Associates, Inc. ---- Engi neers/Scientists/S urveyors 3665 JFK Parkway, Building 2, Suite 200, P.O. Box 270460, Fort Collins, CO 80527 BARB05C.DOC (970) 223-5556, Denver Metro (303) 572-1806, FAX (970) 223-5578 32-0266.00 Printed on recycled paper N a In m 0 O N N 9 o Q a _o Y 0 U C4 o m s > O N r� _ �• Q aQ� r gs H o LL c 1f1 1fl. .. .•V N a•:' •� IV c4i i O � J N o a C O ILL N r N Z "I -Existing grade shall be .-mat fined in these areas --clue.to presence fffaCe9b IM ff I U .41 1 .high retaining walls. ign shall be submitted ie Director of Engineering r to construction. 0.55 V5Y --'F.G. = 5105.0 F.F. = 51106.5 .7 2 span? F.G. = 503-.0 F.F. = 51o4.5 441 .10 r 6'Crosspan 02.0," DIE 'Ol .1,09 5104 15 0.4 .7 F.G. = 5 -T, F.G. = 5104.5 F.F. = 5106.0 F:G. = 5101.0 `F.F. = 5102.5 F.G. :5101.0 F.F. 5102.5 4-2. cis )roperty Boundary 'Q4 4 F.O. 5105. 0� Property Boundar y 7 ---------------------- 4' Concrete Sidewalk Culvert See Detail 10, Sheet 14 Q=1 cfs 202 qC67 cfs 0-5 Place 28 sf Class 6 riprap,, bury 17 and rl 8 k,, �12 • . 03.3 F.G. = 5103.5 F.F. = 5105.0 30" high retaining walls. Design shall -be submitted to`the-.DW6ctor of -Engineering "prior to construction. 5fO2 6098— A-30" ADS N-1 2 1 9 - Riprap'Blanket See Detail 7; Sheet 1 1 14=8 cfs 1, qt�� cfs-