Loading...
HomeMy WebLinkAboutLot Certifications - 02/26/1996 (3)1-1 2,, Z 5� FOUNDATION Engineering, O-� " AND SOILS I� Inc. V4, O `\ ' September 14, 1995 Commission No. 2658-01-06-03 C & C Peterson 3343 Oregon Trail Fort Collins, Colorado 80526 RE: Lot 61, Greenbriar Village Second- Filing (1612 Bayberry Circle), Fort Collins, Colorado — Gentlemen: We have measured the relative elevations of the top of foundation, lot corners, and the side swales at the above referenced address. Based upon our observations, the lot has been graded in substantial conformance with the FHA grading plan completed by Structured Engineering, Inc., Job No. 9301-2ND, dated May 3, 1994. It is also our opinion that the concrete swale to the north of the property has not been affected by the construction of the residence. If you have any questions, please feel free to call. Respectfully, Clifford P. Ham, M.S. Environmental/Earth Sc.i. eriees�':Specia1ist Reviewed y: Kevin W. Patterson, P:'E. >>; FOUNDATION ENGINEERING, 6WO TLTING ENGINEERS, LTD. CPH/jlb 100 East 3rd Street . Loveland, Colorado 80537 • (970) 663-0138 • Fax (970) 663-1660 515 Main Street, Suite C • Longmont, Colorado 80501 • (303) 702-0661 REVISED GRADING PLAN LOT 61, GREENBRIAR VILLAGE SECOND FILING FORT COLLINS, COLORADO V82 Swale 68,6 BM (Back of Walk) .., �� S`OpF' 011crefe Swo/a 691 C.� 068.9 69.4 • 691 69.0 OP \ FINISHED OF 70,g i-OOR � 68,9 682 (Back of Walk):,. r 068.9 068.9 68J 68.3 (Back of Walk) Back of Walk) FOX GLOVE COURT 68.4 Swale 68.5 SCALE : 1" = 20' SURVEYED ; 9 - 12 - FOUNDATION I AND SOILS Engineering, Inc. July 27, 1995 Commission No.: 2658-01-06-02 C & C Peterson 3343 Oregon Trail Fort Collins, Colorado 80526 Gentlemen: We have inspected the open excavation at Lot 61, Greenbriar Second Filing (1612 Bayberry Circle), a subdivision of Fort Collins, Colorado. This inspection was performed on July 26, 1995. Exposed soils indicate the use of a balanced spread footing and/or pad and grade beam type foundation system designed in accordance with the soils report performed by Landmark Engineering, Job No. 2TIGR-93052H-01-709/713, dated June 16, 1993. No water was encountered to a depth of approximately two (2) feet. Due to the anticipated depth of groundwater and/or bedrock below footing elevations, it is our opinion that an exterior perimeter drain is not required for this structure. If you have any quest Res ctfully, ;v Kevin W. Patterson, P:'G�e�� , FOUNDATION & SOILS EN IN KWP/jlb eel free to call. 100 East 3rd Street • Loveland, Colorado 80537 • (970) 663-0138 • Fax (970) 663-1660 515 Main Street. Suite C • Longmont, Colorado 80501 • (303) 702-0661