HomeMy WebLinkAboutLot Certifications - 09/24/2009Q
Stantec Consulting Inc
2950 E Harmony Road Suite 290
Fort Collins CO 80528
Tel: (970) 482.5922
Fax: (970) 482.6368
September 23, 2009
Mr. Jay Barber
Fort Collins Stormwater Utility
700 Wood Street
Fort Collins, Colorado 80522
Re: Grading Certification for Front Range Village I" Replat Lot 7 — Famous Daves BBQ
Dear Mr. Barber:
The purpose of this letter is to certify that the grading of Famous Daves is in general conformance
with the City approved drainage and grading plan with several minor exceptions.
Wagner Land Surveying visited the site in mid August and again in early September of 2009 to
record spot elevations of the curb & gutter, parking areas, and building finish floor. Wagner
Land Surveying also recorded rim and invert information for the new storm drain on the property.
Stantec Consulting Ltd. reviewed the topographic information provided by Wagner Land
Surveying. In general, the recorded spot elevations were within acceptable construction
tolerances. However, several recorded spot shots differed from design grades by over 0.10'. The
design drainage patterns were not modified and no adverse effects are expected.
Stantec Consulting Ltd. visited the site on September 23, 2009, to inspect grading, drainage
patterns and landscaping. Landscaping around the building does not appear to interfere with the
proposed drainage patterns. No low spots were observed along the new curb & gutter or in the
parking areas. Additionally, no cross lot drainage to or from adjacent lots outside of drainage
easements is expected.
This certification is signed and stamped by a professional engineer registered in the State of
Colorado. By signing this certification the engineer attests that to the best of his (her) knowledge
the surveyed grading as shown in the enclosed certification is in compliance with the approved
grading plan for this lot and subdivision as shown on the approved utility plans.
C:\Documents and Settings\jziliak\Desktop\2009-09-22-Grading _Cert.doc , 1 I
1 y�� d ��
Stantec
Failure to disclose all known information could result in the rejection of this certification and
could cause the withholding of the certificate of occupancy for this lot until corrective action has
been taken.
Thank you for your time and consideration of this submittal.
Sincerely Yours,
Stantec Consulting Ltd.
Josh Ziliak, PE
Project Engineer
att: Grading Certification Form
Record Drawing Exhibit
C:\Documents and Settings\jziliak\Desktop\2009-09-22-Grading_Cert.doc
Utilities
electric • stormwater • wasteivater • %rater
City of Fort Collins CERTIFICATION OF LOT GRADING
Pursuant to City Code § 26-544 and
City Land Use Code § 3.2.2 (e)
Date: 9' 23 - 2o09
Permit Application No. VOS034 3Z.
Address: 2 88o E 0.s+ H ar Mo v. v
Lot: 7 Block:
Subdivision: fro^k- 4 ar`u e- V; Ilea c 1st Cf f1Qt
(,(Print) O• a Colorado registered professional engineer,
verify that the. above referenced property in the City of Fort Collins, Colorado, has been inspected by me
or someone under my direct supervision, and verify construction of all stormwater facilities and grading is
complete, and the elevations and drainage patterns shown on the attached drawing(s) which were
sh;d early
developed from a survey performed on (Date)A! 3"s+ • 5rpt. Zoo9 accurately and truly depict the
elevations and drainage patterns as they existed on the date of the survey. Based on this information, I
certify that (check one):
�0 The elevations and drainage patterns of the lot/site are in substantial conformance with the City
approved drainage and grading plan for the property (information attached). SEE NOTE.
❑ The elevations and drainage patterns of the lot/site as measured are in general conformance with
the City approved drainage plan with exceptions (information attached). In my professional
judgment the elevations and grading of the lot as constructed is functionally adequate and will
allow for stormwater drainage consistent with the approved drainage plan.
SEE NOTE.�-
p0 .bIc
s
>a O. lei F� . By:
�� (signature, stamp)
23' 2t . 29So E. Har+r�.r.y te.aol� fart Collars, Ca 8052 g
_��� (address of signing party)
NOTE:'
A COMPLETE certification must be submitted, including but not limited to drawings of the lot/site showing the approved design and
as -built surveyed elevations of all structures, drainage and grading features (e'g. swales, retaining walls, lot corners), written
informationtexplanation of discrepancies, etc. to:
Fort Collins Utilities (970) 221-6700
700 Wood Street
Fort Collins, CO 80521
At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property
Rev. 111106
6.18 R
3fi.]8 FG
36.07 R
36,52 FL 36. R
36.i
5 . .. __ _ 36.90 FG
35.00 GRA
3fi }2 FL 35.2�6
5
36.76 FL HP
4935021 I � .� 8
�35_94 FL
LP a 950J1 & + 49
'\ yp'L£ISe I 1M1 13859 R yy 4M . � NB:.
136.42 R qq q+�Oi� I&
Jj A G'"5665 W9
3 . 2 36.66
Acp
I 3-
3 58H 1936 HP 12 FL 36.87 FG
' /83].50 ill 36.81 FL HP
tt 36.00 F
� g451 1 493)49 � Q9
B36.72 FL I in
A ' C-1 ]U. 1 I 36.49 FL I '�
449.37. I Hq'3' 36,4 tt
2%SWAL6 h y1 I
Yq 493j.42
36 42 R �w
4S 6Fi� iw 4B .V
FRONT RANG ILLAGE
35
35.31 R.
all
�
M9 A q36 37 R W I% J8.11 \, fq OU. 6W �y 35.73 iL 4r I 1 'SCAT .79 R 5
'i5 36.53 FG
3�.97 R 34.9 4.95 R
493S,21
v
HP 36.5J G OC''r'f64 35.04 R
ffm
o 136J3 A \ I YP 35.25 FL 35.64 F
1 a q \ 5. 36.06 R
I f
J8J9 F 06
�¢ Mq Hg4a 1� \ 38.16 R S FG
\ FILL
J6.88 FL
.O8 I f' Jj yS� UO ��MP
36.42 fL1 31i
D.I4 FL e \ 49 1
�37.81 G I 38.d7 R �� \� _ CONTRAMCTO TTO
i 40 CONSTRUCT SIDEWALK'_
III1 _ �_TTOTHISPOINTUNIT'l V
404a '��-4T=�� -3� SIDEWNI(TO nE INTO
F _ \
4p 1 .. T... T l "�� ...... • l 1,
- p /
't L Y' s10EWALKAN0 LE SE IMP UCTE ENT
U FRONT MN(E ,RAIMPROVEMENT
R / PINTS. GONTPACTOR IO CONFIRM MATCH,
INGM➢EB PRIOR TO CONSTRUCTION
---4939--
_. 4940-�
I
v \ I HARMONY ROAD
Is
\ \
gg \
isaoe. M.,-Moia
35 85 5.65
FG
17 00 FG
.80 FG
6.9 F
}1
45.
37.00 FG
CC 8.90 SEE BACK SE
.58
.,4
46
0Q
cRA GDETET.
THISS
HIs sHEEr.
FC
4
N
36.53 FG
M1
?OT
FF
493.00 7.00
]%SWALE
=
Rio a3
E $;
0 11 1 �M1dL LLL -- 9 S
1AL, Y$ F A t EgSFg
PROJECT
0 3
mLOCATION --g D G g� 7
/ O� 10 FgaB§ky
�/ I $ a
IF
\\�\ y v__..... KEY MAP
LEGMD
M� PROPOSED INDEX CONTOUR (DATUM ELEV 49W FT)
LEE NOES' t \ Mf- PROPOSED INTERMEDIATE CONTOUR - 1
88 FG \` - FT INTERVAL (DATUM ELEV 49W FT)
AM FG 1. THE TOP OF FOUNDATION ELEVATIONS - 4940 - EXISTING INDEX CONTOUR
SHOWN ARE THE MINIMUM ELEVATIONS REWIRED
FOR PROTECTION FROM THE 100 YR STORM. - - - 49M - - - EXISTING INTERMEDIATE CONTOUR - 1 FT INTERVAL
33.92 BOW EXISTING STORM SEWER LINE
fj 2 SEE SHEET C-002 FORABBREMATONS.
PROPOSED STORM SEWER LINE
I g
I � PROPOSED INFALL CURB h CUTTER i
PROPOSED SPOT ELEVATION I_9
9ESD aLG73HEETGdD'2 1 #9
FORASRIALTICIXIGRETE I--+- PROPOSED SWALE
D \ PA�^CTKKI __-____
- MADE BREAK I� + - PROPERTY LINE
ME
BOW
I I I•
q�t
° W
I I THICKENED EDGE THICKENED EWE
SLAB SEE DETAIL ON sLFS BEE DETAL ON
-SHEET D.6°1
1� 35.75 FG
3700 FF/A Nq7M.75 FG- 35.75 FG- 35.75 FG
SEE I �p9 PLAN FOR IWALL DETAIL
FREEZER 36.28 PC
.I \ SLAB o 35.90 ED
FF FC 36.7E
ME \ 4937GO
.00 H
36.90 FG bb 36.90 FG 36.90 FIG bb 36.90 FG
3 4 F I \\\ iF f M N m S
.116 G \ 37.Go FF 37.OU FG � W Q
FF ELEV SMOKER
R g O
\ 4937.00 N
C7 LE p
WJ7
I `� BACK OF NODS GRADING DETAIL O Q 0
34.]0 R O K
I ] N LL LL M Z
�r CRY of Fort Collins, Colorado v2 C 1 K
UTILITY PLAN APPROVAL GO u u (D
34.78 Ec 4935
T F 1.0TALL 8 APPROrEO City Enl Me
�. �36 I AND CgAROL CHECKED Bf f_ PBmYFSB0 .••_+•.: •;y4,.a
EKISTTNG gOpE - - OFFSIN FLOWS Water h Waeteevler Utility Ovte
CHECKED B!
SlormWaler Utility Dale
CHECKED BY: I 936\ PROPOSED !PROPOSED P! Recreation Dale
\ / SWALE NORTH O DUVALL CURB CHECKED BY.
/ 20x E: WATER Traffic Er imer D0M
TSr193� T SECTION A CHECKED Date
RES THESE PUNS HAVE BEEN REVIEWED) BY THE LOCAL
' \ ENTITY FOR CONCEPT ONLY. THE RENEW DOES
NOT IMPLY RESPONSIBILITY BY THE RENEWING \ Me 27, 2008 DEPARTMENT, THE LOCAL ENTICY ENGINEER, OR Y
\\ THE LOCAL ENTITY FOR ACCURACY AND
�\ \ CORRECMESS OF THE CALCULATIONS. f5el4p xuxM: 187700050
FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT file KSR mma-1m m
\ CENTS IOF COLFORAW N OUANRIMS OF ITEMS ON THE PUNS PRE THE
1 80 OFCOL 87 FINAL QUANTITIES REQUIRED. THE REVIEW SHALL Aw-� am n 01
\ NOT BE CONSTRUED IN MY REASON AS
ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY WE �. °e4 nMMm
o�7 air LOCAL ENTTY FOR ADDITIONAL QUANTITIES OF
D1XAfiyd No. G170^
fpe mE�eEa unurrs. WWOONK
ITEMS SHOWN THAT MAY HE REQUIRED DURING RBr'Bim BOW
THE CONSTRUCTION PHASE.
M 13