HomeMy WebLinkAboutLot Certifications - 09/24/2009Q Stantec Consulting Inc 2950 E Harmony Road Suite 290 Fort Collins CO 80528 Tel: (970) 482.5922 Fax: (970) 482.6368 September 23, 2009 Mr. Jay Barber Fort Collins Stormwater Utility 700 Wood Street Fort Collins, Colorado 80522 Re: Grading Certification for Front Range Village I" Replat Lot 7 — Famous Daves BBQ Dear Mr. Barber: The purpose of this letter is to certify that the grading of Famous Daves is in general conformance with the City approved drainage and grading plan with several minor exceptions. Wagner Land Surveying visited the site in mid August and again in early September of 2009 to record spot elevations of the curb & gutter, parking areas, and building finish floor. Wagner Land Surveying also recorded rim and invert information for the new storm drain on the property. Stantec Consulting Ltd. reviewed the topographic information provided by Wagner Land Surveying. In general, the recorded spot elevations were within acceptable construction tolerances. However, several recorded spot shots differed from design grades by over 0.10'. The design drainage patterns were not modified and no adverse effects are expected. Stantec Consulting Ltd. visited the site on September 23, 2009, to inspect grading, drainage patterns and landscaping. Landscaping around the building does not appear to interfere with the proposed drainage patterns. No low spots were observed along the new curb & gutter or in the parking areas. Additionally, no cross lot drainage to or from adjacent lots outside of drainage easements is expected. This certification is signed and stamped by a professional engineer registered in the State of Colorado. By signing this certification the engineer attests that to the best of his (her) knowledge the surveyed grading as shown in the enclosed certification is in compliance with the approved grading plan for this lot and subdivision as shown on the approved utility plans. C:\Documents and Settings\jziliak\Desktop\2009-09-22-Grading _Cert.doc , 1 I 1 y�� d �� Stantec Failure to disclose all known information could result in the rejection of this certification and could cause the withholding of the certificate of occupancy for this lot until corrective action has been taken. Thank you for your time and consideration of this submittal. Sincerely Yours, Stantec Consulting Ltd. Josh Ziliak, PE Project Engineer att: Grading Certification Form Record Drawing Exhibit C:\Documents and Settings\jziliak\Desktop\2009-09-22-Grading_Cert.doc Utilities electric • stormwater • wasteivater • %rater City of Fort Collins CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: 9' 23 - 2o09 Permit Application No. VOS034 3Z. Address: 2 88o E 0.s+ H ar Mo v. v Lot: 7 Block: Subdivision: fro^k- 4 ar`u e- V; Ilea c 1st Cf f1Qt (,(Print) O• a Colorado registered professional engineer, verify that the. above referenced property in the City of Fort Collins, Colorado, has been inspected by me or someone under my direct supervision, and verify construction of all stormwater facilities and grading is complete, and the elevations and drainage patterns shown on the attached drawing(s) which were sh;d early developed from a survey performed on (Date)A! 3"s+ • 5rpt. Zoo9 accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): �0 The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. ❑ The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot as constructed is functionally adequate and will allow for stormwater drainage consistent with the approved drainage plan. SEE NOTE.�- p0 .bIc s >a O. lei F� . By: �� (signature, stamp) 23' 2t . 29So E. Har+r�.r.y te.aol� fart Collars, Ca 8052 g _��� (address of signing party) NOTE:' A COMPLETE certification must be submitted, including but not limited to drawings of the lot/site showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e'g. swales, retaining walls, lot corners), written informationtexplanation of discrepancies, etc. to: Fort Collins Utilities (970) 221-6700 700 Wood Street Fort Collins, CO 80521 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property Rev. 111106 6.18 R 3fi.]8 FG 36.07 R 36,52 FL 36. R 36.i 5 . .. __ _ 36.90 FG 35.00 GRA 3fi }2 FL 35.2�6 5 36.76 FL HP 4935021 I � .� 8 �35_94 FL LP a 950J1 & + 49 '\ yp'L£ISe I 1M1 13859 R yy 4M . � NB:. 136.42 R qq q+�Oi� I& Jj A G'"5665 W9 3 . 2 36.66 Acp I 3- 3 58H 1936 HP 12 FL 36.87 FG ' /83].50 ill 36.81 FL HP tt 36.00 F � g451 1 493)49 � Q9 B36.72 FL I in A ' C-1 ]U. 1 I 36.49 FL I '� 449.37. I Hq'3' 36,4 tt 2%SWAL6 h y1 I Yq 493j.42 36 42 R �w 4S 6Fi� iw 4B .V FRONT RANG ILLAGE 35 35.31 R. all � M9 A q36 37 R W I% J8.11 \, fq OU. 6W �y 35.73 iL 4r I 1 'SCAT .79 R 5 'i5 36.53 FG 3�.97 R 34.9 4.95 R 493S,21 v HP 36.5J G OC''r'f64 35.04 R ffm o 136J3 A \ I YP 35.25 FL 35.64 F 1 a q \ 5. 36.06 R I f J8J9 F 06 �¢ Mq Hg4a 1� \ 38.16 R S FG \ FILL J6.88 FL .O8 I f' Jj yS� UO ��MP 36.42 fL1 31i D.I4 FL e \ 49 1 �37.81 G I 38.d7 R �� \� _ CONTRAMCTO TTO i 40 CONSTRUCT SIDEWALK'_ III1 _ �_TTOTHISPOINTUNIT'l V 404a '��-4T=�� -3� SIDEWNI(TO nE INTO F _ \ 4p 1 .. T... T l "�� ...... • l 1, - p / 't L Y' s10EWALKAN0 LE SE IMP UCTE ENT U FRONT MN(E ,RAIMPROVEMENT R / PINTS. GONTPACTOR IO CONFIRM MATCH, INGM➢EB PRIOR TO CONSTRUCTION ---4939-- _. 4940-� I v \ I HARMONY ROAD Is \ \ gg \ isaoe. M.,-Moia 35 85 5.65 FG 17 00 FG .80 FG 6.9 F }1 45. 37.00 FG CC 8.90 SEE BACK SE .58 .,4 46 0Q cRA GDETET. THISS HIs sHEEr. FC 4 N 36.53 FG M1 ?OT FF 493.00 7.00 ]%SWALE = Rio a3 E $; 0 11 1 �M1dL LLL -- 9 S 1AL, Y$ F A t EgSFg PROJECT 0 3 mLOCATION --g D G g� 7 / O� 10 FgaB§ky �/ I $ a IF \\�\ y v__..... KEY MAP LEGMD M� PROPOSED INDEX CONTOUR (DATUM ELEV 49W FT) LEE NOES' t \ Mf- PROPOSED INTERMEDIATE CONTOUR - 1 88 FG \` - FT INTERVAL (DATUM ELEV 49W FT) AM FG 1. THE TOP OF FOUNDATION ELEVATIONS - 4940 - EXISTING INDEX CONTOUR SHOWN ARE THE MINIMUM ELEVATIONS REWIRED FOR PROTECTION FROM THE 100 YR STORM. - - - 49M - - - EXISTING INTERMEDIATE CONTOUR - 1 FT INTERVAL 33.92 BOW EXISTING STORM SEWER LINE fj 2 SEE SHEET C-002 FORABBREMATONS. PROPOSED STORM SEWER LINE I g I � PROPOSED INFALL CURB h CUTTER i PROPOSED SPOT ELEVATION I_9 9ESD aLG73HEETGdD'2 1 #9 FORASRIALTICIXIGRETE I--+- PROPOSED SWALE D \ PA�^CTKKI __-____ - MADE BREAK I� + - PROPERTY LINE ME BOW I I I• q�t ° W I I THICKENED EDGE THICKENED EWE SLAB SEE DETAIL ON sLFS BEE DETAL ON -SHEET D.6°1 1� 35.75 FG 3700 FF/A Nq7M.75 FG- 35.75 FG- 35.75 FG SEE I �p9 PLAN FOR IWALL DETAIL FREEZER 36.28 PC .I \ SLAB o 35.90 ED FF FC 36.7E ME \ 4937GO .00 H 36.90 FG bb 36.90 FG 36.90 FIG bb 36.90 FG 3 4 F I \\\ iF f M N m S .116 G \ 37.Go FF 37.OU FG � W Q FF ELEV SMOKER R g O \ 4937.00 N C7 LE p WJ7 I `� BACK OF NODS GRADING DETAIL O Q 0 34.]0 R O K I ] N LL LL M Z �r CRY of Fort Collins, Colorado v2 C 1 K UTILITY PLAN APPROVAL GO u u (D 34.78 Ec 4935 T F 1.0TALL 8 APPROrEO City Enl Me �. �36 I AND CgAROL CHECKED Bf f_ PBmYFSB0 .••_+•.: •;y4,.a EKISTTNG gOpE - - OFFSIN FLOWS Water h Waeteevler Utility Ovte CHECKED B! SlormWaler Utility Dale CHECKED BY: I 936\ PROPOSED !PROPOSED P! Recreation Dale \ / SWALE NORTH O DUVALL CURB CHECKED BY. / 20x E: WATER Traffic Er imer D0M TSr193� T SECTION A CHECKED Date RES THESE PUNS HAVE BEEN REVIEWED) BY THE LOCAL ' \ ENTITY FOR CONCEPT ONLY. THE RENEW DOES NOT IMPLY RESPONSIBILITY BY THE RENEWING \ Me 27, 2008 DEPARTMENT, THE LOCAL ENTICY ENGINEER, OR Y \\ THE LOCAL ENTITY FOR ACCURACY AND �\ \ CORRECMESS OF THE CALCULATIONS. f5el4p xuxM: 187700050 FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT file KSR mma-1m m \ CENTS IOF COLFORAW N OUANRIMS OF ITEMS ON THE PUNS PRE THE 1 80 OFCOL 87 FINAL QUANTITIES REQUIRED. THE REVIEW SHALL Aw-� am n 01 \ NOT BE CONSTRUED IN MY REASON AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY WE �. °e4 nMMm o�7 air LOCAL ENTTY FOR ADDITIONAL QUANTITIES OF D1XAfiyd No. G170^ fpe mE�eEa unurrs. WWOONK ITEMS SHOWN THAT MAY HE REQUIRED DURING RBr'Bim BOW THE CONSTRUCTION PHASE. M 13