We have measured relative elevations at the above mentioned location. The observed elevations were compared to the
Grading Plan referenced above. During our observations our representative measured the relative elevations at the lots ides
and corners, top of foundation, and lowest openings. Based upon our findings it is our opinion:
A The'elevations as measured are in general conformance with the above noted Grading Plan.
The elevations as measured are In general conformance with the above noted Crading Plan with the following
exceptions:
It is our opinion these exceptions, noted above, should not adversely change the grading scheme as shown on the
above referenced plan.
o During our observations our representative noted that the as measured elevations do not conform to those
indicated on the above referenced grading plan. However, it Is our opinion the grades as measured should
provide an adequate substitute to the above referenced grading scheme.
See the attached "As -Built" grading plan.
13 The elevations measured are not in conformance to the above referenced grading plan. Deficiencies include:
Other comments and/or observations:
Limitatfoov
It is our opinion that the subject lot, as graded on the above date, should not interfere with offsite flows unless the grades are changed
or barriers are created such as fences. garden terracing, sidewalks, and/or any landscaping which may change the cStahli;hed now
patterns by diverting or slowing runoff flow. Backflll adjacent to the residence may settle over time and allow pending to occur
around the foundation walls. Thebackfilladjacenttotheresidencemustbemonitoredandmaintainedtoensurethalnnloffwillflow
miay from the foundation. The grades measured were compared only to the requirements shown on the above referenced grading elan.
Other minimum grading requirements which may be specified in the soils report or by other construction documents are beyond the
scope of this report.
Reviewed by: Advanced Engineering LLC
Jason E. Baker, P.E.
i 33739
`11'b7
04/21/2008 09:12 9702781910 ADVANCED ENGINEERING PAGE 02/03
LEGEND,
T.O.F. - TOP OF FOUNDATION
W.W. = WINDOW WELL
B.O.W. = BACK OF WALK
T.B.M.-1 - TEMPORARY BENCH MARK 1
NOTE, THIS INFORMATION IS BASED ON THE SURVEY PERFORMED ON 4-16-08.
El
SITE PLAN AND GRADING INFORMATION VAS PROVIDED BY CLIENT.
I�
TBM-1
15.9
(BRK)
15.9
(B•O.W.) 16.2
16.7
173 16.9 16.3 <B4O.W.>
I8.1
— � 17.6
18.8
19.4 owes
rr
Ld
T.O.F. = 18.9
�. i.
'
GARAGE
z
:-c
SLAB
W
18.1
al
atss:Ra k-
W.W.
(')
i.
18.8
tiD
18.E 18.5 18.0
16.5
17.2 17.4
17.9 17.2 17.0
}
16,5
CB.O.WJ
(BRK) (B.O.W.)
`AS -BUILT"
OVERL❑T GRADING ❑BSERVATIONS
DATES 4-17-08
MEM
_..•..____..�
CONSULTING, LLC WESTMARK
LOT 39, F❑SSIL LAKE RANCH
6TH
SCALE, r=20'
3105 SUMAC STREET FORT COLLINSO CO
JOB # WEST-03—OIA
FORT
COLLINS, CO 80526
DRAFTED BY, CPH
(970) 988-9774
84/21/2008 09:12 9702781910 ADVANCED ENGINEERING RAGE 03/03