Loading...
HomeMy WebLinkAboutLot Certifications - 02/14/2007Utilities e:ectric siorvlrvater + wastewater. + ivat:r CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: L 4 J 07 Permit Application No. />�a1ayoel Address: S 70 °1 �gCf iti�4i ZEtc Lot: /7 Block: Subdivision: ?;69: ( lkf—lAQ, Z`q;.e.s STORMWATER RECEIVED FFB 14 2007 1,(Print) &.)6J t'��f32¢� a Colorado registered professional engineer, have personally inspected the above referenced property in the City of Fort Collins, Colorado, and verify that construction of all stormwater facilities and grading there is.complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date) fG.A>a.y CL_?�ae'7, accurately and truly depict the elevations and drainage patterns as they existed on the date -of the survey. Based on this information, I certify that (check one): 3e The elevations and drainage patterns of the lot are in substantial conformance with the City approved drainage and grading plan or revised grading plan for the property (information attached). SEE NOTE. 0 The elevations and drainage patterns of the lot as measured are in general conformance with the City approved drainage plan or revised grading plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot as constructed is functionally adequate and will allow for stormwater drainage consistent with the approved drainage plan. SEE NOTE. (signature, PE stamp) . / 103 S._Meldrum St., Fort Collins. CO 80521 (address of signing party) NOTE: A COMPLETE certification must be submitted, including but not limited to drawings of the lot/site showing the approved design or revised design and as -built surveyed elevations of all structures and drainage and grading features (e g. swales, retaining walls, lot comers), written information/explanation of discrepancies, etc. to: Fort Collins Utilities (870) 2214700 700 Wood Street Fort Collins, CO 80521 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property "AS -BUILT" GRADING LOT 17, BLOCK 1, FOSSIL LAKE P.U.D. 2nd FILING 5709 FALLING WATER DRIVE STORMWATER RECEIVED N02000'20"E 76.00' ,gy - - - 6' UTILITY & DRAINAGE EASEMENT FEB 14 2007 +�a9 SCALE.l " = 20' + w + 3 +, x 13.6 s 01 •s `O h � ph 15.6} ^ 14.1 ° FINISH FLOOR = 17.0 x 13.5 ........ �s GARAGE FLOOR = 14.7 pO, REE. DS . . . . . . . . -� --- -=-------l------------ 141 9 .UTIUTY EASEMENT • `�� �� ....: S02°00'20"W 76.00' 1w1 FALLING WATER DRIVE