Loading...
HomeMy WebLinkAboutLot Certifications - 11/02/2006 (2).11/01/2006 0e:47 9702234901 KEM HOMES PAGE 04/17 City of hurt Cull irly Date: .0-74-4160 l Jti llii!`.`� l'I['1,'I I'It' • ':lt�rI111V,11'•f �.1 �ht�i�t}'Jli'I %%ol':r CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Permit Application No. 03% Address: 1-01: M Block: Subdivision: �-�2 STRECEIVED R NOV 0 12006 I,(Pdnt) r es , a Colorado registered professional engineer, have personally Inspected (tie above referenced property in the City of Fort Collins, Colorado, and verify that construction of all stormwater facilities and grading there is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date) /0- /J - arXUrAtaly and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this Information, I certify that (check one): d The elevations and drainage patterns of the lot are in substantial conformance with the City approved drainage and grading plan or revised grading plan for the property (Information attached). SEE NOTE. ❑ The elevations and drainage patterns of the lot as measured are in general conformance with the City approved drainage plan or revised grading plan with exceptions (Information attached). In my professional judgment the elevations and grading of the ctcd io functionolly 0 rli adequate and will allow for stormwater drainage con th• .u��►' ved drainage plan. SEE NOTE. 012 By: /^ �cr3s�% slgning NOTE: I A COMPLETE certification must be submitted, including but not limited to drawings of the lotlsite showing the approved design or revised design and as -bulb surveyed elevations of all structures and drainage and grading features (e.g. swelos, retaining walls, Lot comers), written Inforrnationlexplanation or elscrepanclea, etc. to. Fort Collins Utilities (970) 221.6700 700 wood Street Port Co111n.3, CO 00521 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Properly �&�- 111311)6 •11/01/2006 08:47 9702234901 KEM HOMES PAGE 02/17 Weeks & Associates, Inc. Structural Engineers October 24, 2006 STORMWATER RECEIVE® NOV 0 12006 KEM Homes PO Box 1845 Furl Collins, Colorado 60522 Re: Fossil Lake 2nd Filing Lot 10, Block 13 3503 Green Spring Drive Fort Collins, Colorado Project No. 220112 Gentlemen: I hereby state that the elevations and drainag a pattern shown on the enclosed Final Grade Survey Plan were developed from a survey performed on the referenced property on October 16, 2006, and accurately and truly depict the elevations as they existed on this date. To the best of my knowledge, the surveyed grading is In compliance with the approved grading plan for this lot and subdivision as shown on the approved utility plans. The relative elevations as depicted may change subsequent to the dato of the survey, due to the subsidence or upheaval of soil, addition or removal of soils by acts of man, erosion by wind or water or other factors. Therefore, this survey may not accurately the elevations and drainage pattern of the referenced property after the date of th E mra of Survey The elevations and drainage pattern shown on the attached Plan are the Professional Engineer's findings of the finished ground around your residence on the date shown above. You, the homeowner must maintain these elevations and grades to properly drain the water away from your house. Tho builder of your home will not cover damage to your home nmu;Ad as a result of changes made in the finished grades. In addition, it is our understanding that the RWC limited warranty protection on your residence provided by your Builder will not cover structural damage caused as a result of changes made In Uie finished drainage grades. Therefore, It is your responsibility to maintain the grades as set by the Builder and stated by the Engineer. ' Weeks & Associates, Inc. 30013nardwalk, Building 3, Unit t tion Collins, CO 8OS25 (970) 225-2422 11/01/2006 08:47 9702234901 KEM HOMES PAGE 03/17 1 96.1 REc E VED R Nov 01 2006 FINAL GRADE LOT 10, BLOCK 13, FOSSIL LAKE 2ND FILING 3503 GREEN SPRING DRIVE FORT COLONS. COLORADO S74d57'%7"W C�21,21' K,15•00' 2260-C PLAN 94.5 3-CAR GARACE LEFT 96.7 95.4 • 1600, 97.1 . w :0 x 95.9 RR 97.4�s WW=9.5 BB \ 7.0 97.3 y � 97.1 .2 96.6 FFN S'OLOT AREA=9664 SO. FT. O •a','..:. :'.' 93.6 9 94.5 r' • 96.5 KEM HOMES PROJECT NO. 22002 OCTOBER 24, 2006 WEEKS & ASSOCIATES 94.3 11r�� ?fiC`i E23- 1" = 20'-0" •11/01/2006 08:47 9702234901 KEM HOMES PAGE 05/17 DRAINAGE CERTIFJCATION FORM Please fill out all applicable items in this LerLiti�c,t.iv„ form for single family, multi -family and commercial properties. Write "OK" for items checked or actual number ciic:cked in field. Use "N/An for items that are nvL capplivab'lC tv the Pro;)crty that is being certified. A. Drainage facilities certification 1. fond CertificationA114 -volume verification STORMWATER a.topographin records and volume RECEIVED b.cross-sections and spot elevations -positive fall to pan NOV O 12006 -side slopes -invert elevation -spillway elevation -placement and size of riprap -side slopes _grading -orifice plate installation and size -compaction of berm -structural integrity of pond 2. Swales j11A -location (are they within easement) -dimensions and cross-section verification -longitudinal slopes and side slopes -SpvL elevaLions •11/01/2006 00:47 9702234901 KEM HOMES PAGE 06/17 -permanent erosion control measures (drop structures, riprap, etc....) -tie-in to pipes, pans, curbs, et<;.... -weir size (elevations, size, opeTling, etc.) -available freeboard STORMWATER RECEIVED -landscaping infringement, on swages 3. P1 ea �_ AI- Nov 0 12006 -size and type -slopes (as -built and comparison to minimum 0.T_. siope) pipe capacity calculations if elopes art. significantly altered -invert elevations -in5LdllaLion and backfill mste rial -cover -encasement and clearance from other utility lines close by --j oints 4. Concrete Pan ChannelsA/)ff -size -slope -super elevation -cross .section -thickness -elevations - 5. Inlets //`/� -size and type •11/01/2006 08:47 9702234901 KEM HOMES PAGE 07/17 -size of opening (or name of standard used) -grato olovation -invert elevation -box size 6. Cross -pans Wor -size -type -grade -eleval.iuii -cross-sectional depth -tie-in /to curb and qutter 7. CulverL5AJ/ - R i z a ((( -type -invert elevation -headwalls 8. underdrainsA)/R_ .size -type -covex -backf ill -geotextiles -cleanout's 9. Curb Cuts -size -tie in to Swale, pipe, etc--- STORMWATER RECEIVE® NOV 0 12006 *11/01/2006 08:47 9702234901 KEM HOMES PAGE 08/17 L 0 8. Certification of Grade Elevations Adjacent to Drainage Facilities: p/�-minimum opening elevations STORNIWATER D%C-top of foundation elevat.i.ons RECEIVED -comparison to 100 year WS6L's (Freeboard NOV O 12006 .requirements and fioo(lplain innues) C. Certification of Erosion Control Measures: 1. Permanent Measures: h//R -Permanent vegetation W' bare .spots �tnd wPe(ls unde.T' control) -•riprap -riprap bedding -drop sections -sediment basins/water quality ponds -119Lting mats/blanket3 -mulching / 2. Temporary Measures_:%y -mulching -inlet filtar installation -check bale dams -seeding and temporary vegetation -silt fence D. Site Cleanup After Construction 04 -construction clean up 41t smoothing of. rute -reseeding E. Statement of Compliance •11/01/2006 00:47 9702234901 KEM HOMES PAGE 09/17 This certification is signed and stamped and by signing this form the engineer(s) aLtests that they have i.nspec:Led the site and to the best of thei..r knowledge L•he as -built conditions of the drainage fau.kliLiea site: as de4sc.:r Lbed ir, the above form and in the rcdlined plans ericloscd_ Failure to properly disclose all known information could result in the rejection of this certification and prevent the release of any Sto.rmwatcr Ut.iliLy nolds on Building Permits and/or Certificates of Occupancy. F. Signature and Stamp by a Colorado Registered processional Enginnar- G p STORMWATER ?�9 RECEIVED 0 y 12006 Sol JNOV 0 FSSlON pl�