HomeMy WebLinkAboutLot Certifications - 09/22/2000 (2)STONYBROOK HOMES INC .970 667 2342 P.02
CEO-- 3oo l�
SCOTT, COX & ASSOCIATES, INC. consulting engineers
v
August 29. 2000� U�
Stonybrook
P.O. Box 2425
Loveland. Colorado 80539.
Project No. 1067-27-04-01
Gentlemen:
We have measured the relative elevations for the over lot grading at Ut -2_6.-Block 10. Fq: sit-L-ake-Ranch.-(-.- 05-Rookery
Road) Garimer County . Colorado. During the investigation, we measured elevations at the lot sides and corners, top of
foundation. lowest opening,.and the drainage swalcs on the east and west sides of the subject lot.
Our representative noted that the observed elevations forthe southwest and southeast property corners were approximately
five -tenths to seven tenths of a foot (0,5'-0.7) lower than indicated on the Grading and Erosion Control Plan for this
subdivision. Our representative also noted that the observed grades adjacent to the northeast portion of the subject
residence was approximately eight -tenths of a foot (0.8') lower than indicated on the Grading and Erosion Control Plan.
The difference in elevation from the northeast portion of the subject residence to.the swale on the east property line is
approximately two feet (2').
Based on our observations, and the information available to this office, the slopes and elevations as measured, with the
above noted exceptions. are in general conformance with the intent of the Grading and Erosion Control Plan completed
by Northern Engineering Services, Job Number 9812.00FLF, dated. April 2. 1999. Please refer to the copies of the AS -
Built Grading Elevations, the Grading and Erosion Control Plan for further information.
Furthermore, it is our opinion that the subject lot, as graded. should not interfere with offsite flows unless the grades are
changed or barriers are created such as fences. garden terracing, sidewalks andfor an% landscaping which may change the
established flow patterns by diverting or slowing runoff flow. Backfill adjacent to the residence may settle over time and
allow ponding to occur around the foundation walls. The baekfill adjacent to the residence must be monitored and
maintained by the homeowner to ensure that runoff will flow away from the foundation.
Thank you for consulting with us on this phase of the project. If you have any questions, please
Sincerely,
SCOTT, COX & ASSOCIATES
Rc%iewed by:
Ctiflur . H m.
Environmental S ialist
F. rECHs'(11FFGIUDINGSton}brook'1067.27-4•I.opd.
App by:
James A. Cherm. P.E.
call.
32055
2 9 20p�`�;
• ,.....•�v�
,110 Cranite Street, Slide D • Lov0land , C010rad0 305i3 s hb t•nl in '.,• 0-0 665-I660
irnbq CokNadr,arf, Wrices �n iouuL" •. .'••.�••ml �,n'+e..
STONYBROOK HOMES INC 970 667 2342' '.P.03
K�RY R0AV.
Rp0
NORTH
TBM -1 01.0 a
ELEVATIONS SURVEYED
A49-waA
,
a
• a
a
99.1
023 03.1 02.9 00.9
02:9
(Iwst)
Top of Foundation=04.ro }.
04.0 I 01.5
02.,6
04.3 I
(Iwst) 03.1
04,1 i 01.9
02.-T • i
�wSO 1 f04.2
03,5
O e:4 1
1
I
l
I
0ro.5
Oros
NOTE:
THE THE
ELEVATIONS ERFO HERE N 8-25 BASED AS -BUILT GRADE .ELEVATIONS
ON THE SURVEY PERFOF7!"IED ON 8-79-09.
jOB ND.
I061-21•4•1 -5TONYBROOK .
DATE8C�OTT, COX ♦ E.n OGIA'i�S, INC.
8-2-]9-00 Gonsuleine EnglnarrA Lot zb, BLOCK 10, F0551L LAKE RANCH
SCALE 5n0 ammo E1rMl. EuNe D - LordYno, ColosOo 00538
I', 20.0'
DRAWN, .Po�W 663 • 0U6
DAP
1 ,
`
• -��,• ' �' .} .r �.,.�j,.sti�. .�' i..� -,lam -•�lj• i.'{'�.. ..C.. �� •5'�'•�'
� '.S• . •' �' . .{, `, � 1'�}��1�• �."I � .�,,! .. t• It 1� �_i rr,� -
4.3
�...
• .` w� a • '.fir ♦�ti t�. OR
fit' `' : , �.~ �� i ••
I
w?
Maw
r i!