Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Lot Certifications - 04/10/2007 (6)
' 04/09/2007 08:17 9702781910 ADVANCED ENGINEERING STOR A- �`R PAMM W Ow I&C RECEIVE® 3103 Sumac Street Fort Colligg, Celmdo 00829 APR ' I Phori �988A774 Fax, (970 49L" 8-o, 9 APPR 0 9 2007 h,mdthem4+aol.mm QVERLOT GRADING OBSERVATION DATE: ,a -G-p- CLIENT: &Z045E42:;- Co�Jsr r 7c;t.i MEM JOB #: �q -01-Q )A LEGAL: f, oT-S &OCK % ho56a LA,&& ZrtP INSP. BY: ADDRESS: _34Z� 't�1,r.�JrGaJ �ia.yE SITE/GRADING PLAN: �3eA0 �,j �`. >tc�� OoFCS T�14T60''F30�0) We have measured relative elevations at the above mentioned location. The observed elevations were compared to the Grading Plan referenced above. During our observations our representative treasured the relative elevations at the lot sides and corners, top of foundation, and lowest openings. Based upon our findings it is our opinion: a The elevations as measured are in general conformance with the above noted Grading Plan, 16 The elevations as measured are in general conformance with the above noted Grading Plan with the fnl Inuwinu It is our opinion these exceptions, noted above, should not adversely change the grading scheme as shown on the above referenced plan. o Dgring our observations our representative noted that the as measured elevations do not conform to those indicated on the above referenced grading plan. However, it is our opinion the grades as measured should provide an adequate substitute to the above referenced grading scheme, bt Seethe attached "As -Built" grading plan. The elevations measured are not in conformance to the above referenced.grading plan. Deficiencies include: Other comments and/or observations: Limitations; ' It is our opinion that the subject lot, as graded on the above date, should not interfere with offsite !lows unless the grades arc changed or barriers are created such as fences, garden terracing, sidewalks, and/or any landscaping which may change the established flow patterns by diverting or slowing runoff flow. Backfill adjacent to the residence may settle over time and allow ponding to occur around the foundation walls. The baekfill adjacent to the residence must be monitored and maintained to ensure that wnotiwill flow away from the foundation, The grades measured werecompared onlytothe requirements shown on the above referenced grading plan. Other minimum grading requirements which may be specified in the soils report or by other construction documents arc beyond the scope of this report. R Reviewed by: Advanced ,Engineering, LLC Jason E. Baker, P.E. 04/09/2007 08:17 9702781910 ADVANCED ENGINEERING PAGE 02/03 STORMi/ WATER RECEIVED APR 0 9 2007 2 C7 TBM-1 99.4 (B.❑.W') 99.9 00.3 J/ LEGEND; T,O,F. = TOP OF FOUNDATION W,W = WINDOW WELL B.O.W. - BACK OF WALK T.B.M.-1 = TEMPORARY BENCH MARK 1 © PLEASE REFER TO MEM LETTER BRON-01-OIA / DATED 4-6-07 oqc�j 14 lh� 97.7 0.9 Y• e , .A (B.O.W.) OO.S CRAK ` 01.0 L W.W. = 02.0 01.6 ✓ 97.0 - 01.2 T.O.F. = 02.3 (B.❑. W, ) f . 99.4 W. W, a 02.0 f 01.4 01.7 3 01.9 / 96.7 } WSW. = 98.9 (B.❑.W.) 01.6 'f 01.6 [-+obi 1.7 98.6 ,s q� ID 96.7 .p coZ-3 00.9 (B.O.W.) �Q Q01.8 y 98.1 01.0 � 00.1 \ \ \ NOTEa THIS DWORNATION IS BASED ON THE SURVEY PERFORKD ON 4'-9-07. SITE PLAN AND GRADING XWORMATMN PROVIDED BY CLIENT. . 96.4 (B.❑.W.) 'AS -BUILD"- OVERLOT GRADING OBSERVATIONS DATE, 4-6-07 /It MEM CONSULTING, LLC BRONSERT CONST, SCALE, 1'=20' J08 R BRON-Ok-OlA /�jj�� / 3105 SUMAC STREET LOT. 5, BLOCK 6, FOSSIL LAKE 2ND i FO FORT COLLINS, CO FORT COLLINS, CO 80526 DRAFTED Vi CPH (970) 988-9774 No Text