Loading...
HomeMy WebLinkAboutLot Certifications - 04/10/2006 (4)Utilities electric • stormwater wastewater • water City of Fort Collins Date: DL1 - 5 - o (e CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) STORMWATER RECEIVED APR 0 6 2006 Permit Application No. 5050 3500 / Address: 352� v.9;ldv;cw [)riya Lot: iA Block: 12 Subdivision: Fosc,, 1 l eke rQ(\vA_ (,(Print) e crr y , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or someone under my direct supervision, and verify construction of all stormwater facilities and grading is complete, and the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date) 0 3 - oS • oto , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. ❑ The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot as constructed is functionally adequate and will allow for stormwater drainage consistent with the approved drainages SEE NOTE. signa � s +!!Jr i NOTE: A COMPLETE certification must be submitted, including but not limited to drawings of the lot/site showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written Information/explanation of discrepancies, etc. to: Fort Collins Utilities (970) 221.6700 700 Wood Street Fort Collins, CO 80521 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property Rev. 111106 a Final Grade Assurance Observation: Per the clients request, a representative of SECURE has visually observed and measured elevations of the grading around the home at the site referenced below. The following summarizes our observations and opinions at the time of our visit. SECURE' CONSULTING ENGINEERS MOW A CTL I THOMPSON COMPANY Client: Site Address: 3527 '��. io•f Co ti..z CO Secure Job#• 5FOoq, I Lot: 9 Block: 12 Filing: Date: 3 - 5 - 0 6 Contact:. C. ". lac Subdivision: Foss;.) Lc ke Background Information: Referenced Grading Plan: �' l kt•, "`f er.;. v Dated: �/'.;0 -0I Job4: g159.60FLS STA Measurement Elevation Remarks 1 O 9 1.7 N w to V eol el 2 -6.S r13_z NE Lol•Ca.-.r, 3 0.5 94 2 4 1 . Ci 15.6 Nu L.,-me in,,.r, 5 2.1 U r. !Icb 6 1. 7 pSS.8 15.4 N a (ia c 7 0 3.7 8 1.0 . 7 9 2.7 G it. ii htj 10 3.9 97.6 T.O.F. I1 1 2.5 116.2 12 0.7 9 4. 4 13 1-5 75.Z. 14 - _ 3 9 7. 0 - 6 EL5c Co•.r, 15 3.3 Ci7.0 16 2.4 36- I S1 No,. 61..,- 17 1. Q 1q.7 18 1.6 95,3 HP 19 22 9 5. 9 SU to+ G-r- 20 2.2 45.y 21 I.9 55.6 5F Id Cel...e, 22 23 24 Site: F... �. Iv 1c,4 fa PG$ 4 4and.<c4ged Ws >0 So4It, . Loh -to' ... er! /S [. lctrp! n LN1�Q/ /lw.'s h Summary of opinions: UO It, is our opinion that the top of foundation and grades around the home are consistent with the above referenced grading plan or are a functionally adequate substitute. ❑ Rejected (2nd observation required) Corrective action: r.' � 1� r, WA I Secure Foundations, LLC 9 211 West Magnolia Street, Ft. Collins, CO 80521 • Ph: 970-472-6255 9 Fax: 970472-6256 .GENEfRAL NOTES: — PROVIDE ADEQUATE DRAIANGE AWAY FROM THE STRUCTURE. REFER TO THE SUBDIVISION GRADING PLAN FOR ADDITIONAL REQUIREMENTS. SECURE RECOMMENDS A I FT FALL IN THE FIRST TEN FEET ADJACENT TO THE RESIDENCE THEN, 2% SLOPE FROM TWAT POINT TO THE PROPERTY LINE FOR LANDSCAPED AREAS. CONTRACTOR TO VERIFY ALL DIMENSIONS INCLUDING BUT NOT — LIMITED TO LOT LINES, SETBACKS, EASEMENT, COVENENTS, OR ANY OTHER REQUIREMENTS THAT MAY AFFECT THE LOCATION OF THE HOME ON THE LOT. NOTIFY SECURE OF DISCREPANCIES IMMEDIATELY. SET TOP OF FOUNDATION PER THE APPROVED GRADING PLAN — OR BY LOCAL CODE. LOCATE ALL UTILITIES AS REQUIRED BY COLORADO LAW 3 — PRIOR TO ANY EXCAVATION AT THE SITE. 4 STORMWATER RECEIVED APR 0 6 2006 96.0 1� `15 a SITE PLAN 1'f Ib IB% / ss .. > h �v X t0 95 \S �T Li'l 2034' 511'34'24'E CLIENT: CUSTOM ENVIRONMENTS SITE: 3527 WILDVIEW DRIVE LOT 4, BLOCK 12 FOSSIL LAKE RANCH FORT COLLINS, CO 5 93.1 _I C2l L = 23.56' R=15.00' CHD =2121' a 'a a `'l i1 z � a � 3.2 C'O IC, e 4RIvF G Q % @ 210r 20 FT FRONT y 22.00 SETBACK Z-' s s. 6 0m h h / �MQ � h V h � SI NC MI r 96,E 97.6 0 k _QI IS 1(o.t iv U / .ill rot 3 95.q SECURE 211 W. Magnolia. Suite B Fort Collins, CO 80521 P: (970) 47272-6255 CONSULTING ENGINEERS, LLC F: (970) 472-6256 DBAI(dl: SHEET JAC r PROJECT./ SF05-959 OF DATE: 06—a0-05 in SCALE r-20'