HomeMy WebLinkAboutSite Certifications - 10/16/2005North Star Ianaw design, inc. October 16, 2005 Jay Barber City of Fort Collins 700 Wood Street Fort Collins, CO 80524 Fax:221-6619 Mr. Barber, This letter and attached information is provided to certify that the Phase 1 (Lot 4) drainage improvements at Eastgate P.U.D. Lots 4 and 5 described below have been constructed in substantial conformance with the approved plans dated November 10, 2004. All elevation information is based on surveys completed by RJL Surveying (10/12/05). A site visit was also completed on 10/13/05. This certification includes the following improvements: • The offsite pond was not certified. • The Phase 1 (Lot 4) building finished floor is 0.02' above the design elevation. • The Phase 1 building was constructed 3' closer to the northwest property line (shown on the attached drawing), therefore the parking stalls against the building are 20' deep rather than 17' deep. • A concrete pan (shown on the attached drawing) was added along the northwest property line to facilitate drainage on that side of the building • Per a site visit, the metal sidewalk culverts have been constructed. • The curbs on site appear to be in substantial conformance to the grading plan and convey runoff to the off site pond or to Riverside Avenue. • The landscape areas have been sodded or otherwise planted per the approved plans. In general, based on the site visit and the information provided by RJL Surveying, the runoff from the site will be conveyed to an acceptable release point. The building location as constructed was not verified to meet applicable setbacks. Please call me if you have any questions or if&lo need any additional information. REG �e PP.• � _ op. G� KRp��9�o� cr ici Kroet h, o • 06 : ��` SRO N AU 700 Automation Drive, Unit I Windsor, Colorado 80550 � �L' �� S 970-686-6939 Phone 970-686-1 1 88 Fax otkax p09�' ter\ +a sb .•/ �\ ��\\� FAy ITS Y METAL SDTE C" NNEL i RE AT 1. SEE ME i a = AA `-\\ \ \ •\ ` 1 IC CL\KRi A 1 / O~NL Cp1ERElE SIN \ \ AV AT 5 MAX OFF 0 \ LOT p IT /• 4 ORAWACE / \ L EASEMENT \ NANDI PARKING SIGN- PROPOSEDK.4 em.mrvc S noC iAL.AOENMM FF4r COLKRT T 2A SLOPE NA A].12 -7L III IRS v >ARO Ti ---------------- t1 0 zIDS Q a J r-I — W II n � � / k WTTER w/ PAN. TN. LOT 5 PROPOSED BUILDING 'FE-•5,0 `HANOCAP SIGN' EMSI EDGE OF PAVEMENT 07I1, EXISTING owONEWAA:w.sl`SNom ®� • Y CONCRETE CHANNEL A \_ Ai 1.GR 4CK OF \ \\\\\ Lori i �o mm Im DO 09P?w oo� 5- d .� ^ 0 {'SC g3aaLL 20 10 O 20 40 SCALE: 1- . 20' ApI' a � o ' 0 w1 6 NOTES 1. ALJ SPOT ELEVATIONS ARE FLOWLINE UNLESS NOTED OT ERVASE. 2. CURLLIB AND GUTTER ON SITE IS VERTICAL WITH A V PAN. O ry a \ a 3. AL ON SITE STORM DRAINAGE FACILITIES SHALL BE MAINTAINED N II BY THE PROJECT OMER OR OVINER S ASSOCIATION. ALL STORM \ S� DRAINAGE FACILITIES WITHIN THE RI"t7 OF WAY SHALL Rr a MAINTAINED BY THE CITY OF FORT' INS LEGEND 1 HE HIGH PONT 11 LP LOW PONT Fir FINISHED FLOM n TOP OF FOUNDATION ECP EDGE OF PAVEMENT --- - -- EXISTING CONTOURS " - - ---MPID— -- EXISTING INDEX CONTOURS PROPOSED CONTOURS 49015 PROPOSED INDEX CONTOURS ----••--- PROPOSED P.GALINE -- ---- PROPOSE: INFLOW CURB PROPOSED :".';ALL C-aB ------ — — -- PROD^SEC : 'ONCRE F PAN Z PPODC•EJ DRAIN PIPE Q J RII PEC:q3 DRAWNG ULEVA"ON fi W v Q CC cD s�ppyy ~ FlCAT011 CENTER OF CORADO GALL UTILITY Nfm1987 W O J J `r 9800-92 �' CrLyt z-eOsussz GIN ADVANCEyIX1E YGII plGf GNAGR EXCAVATE ��A IRE M NG 0-NDERLApMD e' i Q City of Fort Co h, Colorado UTILITY PLAN APPROVAL APPROVED:_ _ CL Fn9Ina (I CHECKED BA: _ SHEET R IW a WINSMIA, UIFir EPA CHECK=,^, H•'.5m. .w U1LNX Del. CHECKED By:-- a_ .: m.e1Kn Del. CHECKED BY:____�_ 4 OF 6 T._ r.. a-9 ne and CHECKED BY:_..____ Date