Loading...
HomeMy WebLinkAboutLot Certifications - 06/21/2006JLN-19-2006 07:50 FFZOM: TO:2216619 P.2 Utilities electric • stormwater • wastewater • water CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: 06/16/06 Permit Application No.��oZ1�y/ Address: 6570 Rookery Road Lot: 7 Block: 12 Subdivision: Fossil Lake PUD 1" Filing STORMWATER RECEIVED JUN 19 2006 �.0� y , ... (,(Print) Wyatt M. Knutson . a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or someone under my direct supervision, and verify construction of all stormwater facilities and grading is complete,. and the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date) 06/16/06 accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): L] The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. ❑ The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot as constructed is funct' all adequate and will allow for stormwater drainage consistent with the approved dr " Kj(CF SEE NOTE. KNv s�5i c•• '3 38108 z' . By: bb/�¢ (si ature, P , p). of signing party) NOTE: A COMPLETE certification must be submitted, Including but not limited to drawings of the lotlsite showing the approved design and as-bullt surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written Inforrnatlonlexplan2don of discrepancies, etc. to: Fort Collins utilities (970) 221-6700 700 Wood Street Fort Collins, CO 80521 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property Rev. 1H/06 -P,ku -v 6 JUN-19-2006 07:51 FROM: TO:2216619 P.3 Final Grade Assurance Observation: Per the clients request, a representative of SECURE has visually observed and measured elevations of the grading around the home at the site referenced below. The following summarizes our observations and opinions at the time orour visit. SECURE CONSULTING ENGINEERS A CTL i T14OMPSON COMPANY Client: f Site Address: oc�keq-RoAci. PO BGk 2705IS Fn+ C'an&i,� $AS27 :EOX± CnIIIpS�C-n Secure Job#: SFooA9S Lot: - 7. Block: 1-4 Filing: sSt Date: 06/02/06_ Contact'. Toni. Subdivision: Fncci l I akp PUD Backeround Information: Referenced Grading Plan: NOrthern Elgp�nP¢rtn_� Services Dated:09/20/4q Job#: 9812-00FLF STA Measurement Elevation Remarks I o.00 4890.40 2 -0.03 4896. 3 -0.09 469G.31 4 -0.08 2 5 0.11 4896-51 6 0.31 a8g6.7 i 7 1.04 4997.44 8 3.44 48gg-84 9 3.39 4 419-79 10 3.34 .'1 11 6.59 6_ 12 2.-79 4 - I9 13 2.89 489g.29 14 3.03 489q.4b 15 3.67 4900-07 slab 16 3.59 48g9_98 17 t.64 4898-04 i8 2.54 4818.9 19 3.01 469g.41 t•O.W. 20 2.97 g8gq.37 21 G.24 44o2.64 flirti--ghecl floor 22 3.51 4 _qt 23 I-84 48g8-24 24 -0.45 405-95 Site: See attached ;. 7..r. F • � t SuInroary of opinions: It is our opinion that the top of foundation and grades around the home are consistent with the above referenced grading plan or are a functionally adequate substitute. ❑ Rejected (2ad observation required) Convective action: 16 io6 Fiel Represe ativ PpO L7 V 38108 Z' i� p'. ob 6 Re . wed By Secure Foundations, LLC • 211 West Magnolia Street, Ft. Collins, CO 80521 • Ph: 970.472-6255 • Fax: 970-472-6256 JUN-19-2006 07:51 FROM: TO:2216619 PA Final Grade Assurance Observation: Per the clients request. a representative of SECURE has visually observed and measured elevations of the grading around the home at the site referenced below. The following summarizes our observations and opinions at the time of our visit. SECURE CONSULTING ENGINEERS A CTL I THOMPSON COMPANY Client: Branneo n csuz ♦ Cpn%�rurtten Site Address: GS7n PG Bee 27057A 1=ej4(' l lrnS M Ra�27 a, nt Secure Job#: SEMR9S Lot: �_ Block: J7. Filing: I"t;tr Date: nC tortnG Contact: Ten.. __ Subdivision: :Fo,CCi I La kp POD. Background Information: Referenced Grading Plan: NOI 1i1 .rn F19flliieet $er6ceS J Dated: 44120/99 Job#: 9f312 W FLF STA Measurement Elevation Remarks 25 1.30 4897.70 26 1.GO 469&00 t.o.w. 27 1.51 4897.91 3.45 4899.65 29 3.31 4899.71 .0.w- 30 S-08 48gq .413 31 - 0.54 4995,86 32 1.91 1996.31 33 2.4 2 4898.52 34 2.61 899.01 35 Z. Be4 9- 28 36 2.96 4 99.36 3-7 3.25 12l9cl .6 35 3.16 4900.16 3q 3.G4 19MOA 40 3.10 4N9.56 41 2.a7 4699.37 42 1.61 4898.2P 43 - 0.6 2 499S.16 44 0.72 4897.12 45 1.A2 4 7.82 4G 1.72 4898.12 47 -1-04 4595.36 Swale 48 1 O 1489G.,40 Swale Site: see .a ttachecl �.t. �... .... _tom._-;-•._r_ STA Measurement Elevation__ Rtma-AS 40i 0.61 97. 21 Svva 1e 50 5:21 489T.61 Swale STORMWATER RECEIVED JUN 19 2n Secure Foundations, LLC • 211 West Magnolia Street, Ft. Collins, CO 80521 • Ph: 970-472-6255 • Fax: 970-472-6256 JLH-19-2006 07:52 FROM: TO:2216619 P.5 STORMWATER RECEIVED 6401 JUN 1 9 2006 t 44 45 4 P.4070 I 11-C 33 34 35 40 4t A + 22 2.3,, 15 oleo y M MY- 7 10 2.! 3 q t-4 JLJN-19-2006 07:52 FROM: TO:2216619 P.6 S ORMWATER RECEIVED a 3dU Z6 rce UN 1 9 2006 rd, r rI i 6� r• ' owA o•Q�0 3au an �a ' [ 63 •0� MR z !, Fe u C'l0 •!l Nql ! I I 0A — — r y 0 3017 LOl i s '6' .0 mil NM .-.. _ •- .