Loading...
HomeMy WebLinkAboutLot Certifications - 06/24/2014 (8)Utilities City of electric. stormwater. wastewater. water ` Fort Collins 700 Wood St. POBox 580 Fort Collins, CO 80522 970.221.6700 970.221.6619 fax . 970.224.6003 TDD utilities@fcgov.com . fcgov.comlutllities CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: 06/23/2014 Permit Application No. B1400813 Address: 327 Bannock St. Lot: 13 Block: 5 Subdivision: Dry Creek co fi'MS-30A (,(Print) Cody A. Geisendorfer,aColorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): 0611612014 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one) ❑ The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. t' The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormwater drainage on and off th/ej llooft/siteeiin a manner consistent with the approved drainage plan. SEE NOTE. By: t�LBtHU oPPOU t-�CF (signature, PE stamp, email address) C.i C'�ISP4'O0F0 1501 Academy Court, #201 ° 41326 'n o V � Fort Collins, CO 80524 �O�FS�._ � (9 7 0) 416 — 7891 (address & telephone number of signing party) NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the IoUsite, including but not limited to drawings of the lot/site showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written inforrnationlexplanation of discrepancies, and other information necessary to confirm the above certification to: Fort Collins Utilities 700 Wood Street Fort Collins, CO 80521 (970)221-6700 Rev. 1127112 Submit Two Weeks Prior To Requesting A Certification Of Occupancy For The Property QUALITY `x ENGINEERING Date: Permit Application No. Address: Lot/Block/Subdivision: Exception: W W W. QUALITY-ENGI NEERI NG. COM CERTIFICATION OF LOT GRADING June 23, 2014 B1400813 327 Bannock St, Fort Collins, CO. Lot 13, Block 5, Dry Creek The southwest and southeast lot corners do not match subdivision grading elevations due to as -built construction variances; however, subdivision grading intent is still met. QUALITY ENGINEERING, LLC (970) 416-7891 1501 ACADEMY CT, SUITE 201 FORT COLLINS, COLORADO o , w o i�r O 4/ 7sy Qa = v z s nJ m'DO am p N O j,V ci 4/ l i . �n ~ai9e / / Ts i. „g \` w (A w m NO r / ti \% i, l`• -n w 3 •rj •JS I ssJ GS j -< 0 m �� �o zoy zm o m r z UI m z Z �m g20a 00 '� m00CC0-' M5zMwM0 vMMo<zm'i DOAczD< ((1) � m0� 'T)i0z z � m ram` zi r VA OOTZ z�ibv� _4 C13 US � U0 �m 0 0 0 0 C N m ni 1 d 1 l QUALITY DRY CREEK SUBDIVISION i LOT 13. BLOCK 5 \x ENGINEERING 327 BANNOCK STREET, FORT COLLINS 1501 Academy Court #201 Fort Collins, CO 80521 (970) 416-7891 LOT GRADING PLAN NO. REVISIONS BY DATE No Text