HomeMy WebLinkAboutLot Certifications - 03/25/2014 (6)Utilities
(~.'
electric. stormwater. wastewater. water
r
rM \F&t-COIM
Of
700 Wood St.
POBox 580
s
Fort Collins, CO 80522
970.221.6700
970.221.6619 fax . 970.224.6003 TDD
utilitfes@fcgov.com . fcgov.com/utilities
CERTIFICATION OF LOT GRADING
Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e)
Date: 03/24/2014
Permit Application No.
B1305497
Address: 538 Muskegon Court
Lot: 8 Block: 1
Subdivision: Dry Creek Subdivision
Cody A. Geisendorfer
rcl+.0.ud
a Colorado registered professional engineer, verify that the
above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately
qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading
is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed
from a survey performed on (Date): 0 3 / 1 9 / 2 014 , accurately and truly depict the elevations and drainage
patterns as they existed on the date of the survey. Based on this information, I certify that (check one):
❑ The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved
drainage and grading plan for the property (information attached). SEE NOTE.
'Ei The elevations and drainage patterns of the lot/site as measured are in general conformance with the City
approved drainage plan with exceptions (information attached). In my professional judgment the elevations
and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically
approved drainage plan, and will affect stormwater drainage on and off the lot/site in a manner consistent
with the approved drainage plan. SEE NOTE.
eDO l/ By:
0'.-0 Fn, (signature, PE stamp, email address)
1501 Academy Court, #201
Fort Collins, CO 80524
(970) 416 - 7891
(address & telephone number of signing party)
NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the lot/site, including but not limited to drawings of the IoUsite showing the approved design and as -built surveyed
elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written,
information/explanation of discrepancies, and other Information necessary to confirm the above certification to:
Fort Collins Utilities
700 Wood Street
Fort Collins, CO 80521
(970)221-6700
Rev. 1127112 Submit Two Weeks Prior To Requesting A Certification Of Occupancy For The Property
QUALITY-
`x ENGINEERING
m
W W W. QUALITY-ENGI NEERI NG. COM
CERTIFICATION OF LOT GRADING
Date: March 24, 2014
Permit Application No. B1305497
Address: 538 Muskegon Court, Fort Collins, CO.
Lot/Block/Subdivision: Lot 8, Block 1, Dry Creek Minor Subdivision First Replat
Exception:
Back of lot corners do not match subdivision grading elevations due to as -built construction variances;
however, subdivision grading intent is still met.
R
QUALITY ENGINEERING, LLC (970) 416-7891 1501 ACADEMY CT, SUITE 201 FORT COLLINS, COLORADO
�
C)
C
0
c
c
C
A o
Fri�
/
/o
<
0
co -
.
z�m
\/
\\\§
&
// /»
!
SITE PLAN
O7: ENCORE HOMES, LLC
7wlat��aaw_
mr ,e* Fort eRins
\"-jIz3
§\ 2am
Sm /r
e
/ $/
§
\o� zz j 7
\
±5���
6
_
CTL | THOM PSON r
PROJECT
& l • -. . �a ,
k»���° |�Cdthanvswx' ]
C:`2xje-
\✓.
i-- - - - - - -----
m '10,
ter-
- , �9 � -17
— A
�
I I
�,�
•sue
�
I
I
+� v
cr)
c
0
N
C
ED
ED
0
0
I
W��°
`
1
C
o � a]r��
�,.
cn
:3
6,fl
- J4
I •
•
y9
S�
J
I
I
Di�
O
No
/
9
r
i