HomeMy WebLinkAboutLot Certifications - 03/11/2014 (3)r Utilities CI.,�.V" OT electric. stormwater. wastewater. water _ J 700 Wood St. PO Box 580 Fo7tc, 0 n, Fort Collins, CO 80522 970.221.6700 970.221.6619 fax . 970.224.6003 TDD utilities@fcgovcom . fcgov.com/utiiities CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: 03/14/2014 Permit Application No. B1306371 Address: 508 Bannock Street Lot: 3 Block: 2 Subdivision: Dry Creek Subdivision tI500 aScrowcd (,(Print) Cody A. Geisendorfer , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): 0 3 / 11 / 2 014 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the IoUsite are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. Nr" The elevations and drainage patterns of the IoUsite as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the IoUsite as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormwater drainage on and off the loot(site�in a manner consistent with the approved drainage plan. SEE NOTE. P001t� By: t�tBGU1 44,- (signature, PE stamp, email address) 1501 Academy Court, #201 Fort Collins, CO 80524 (970) 416 — 7891 (address & telephone number of signing party) NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the lot/site, Including but not limited to drawings of the lot/site showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written Informationlexplanation of discrepancies,, and other Information necessary to confirm the above certification to: Fort Collins Utilities 700 Wood Street Fort Collins, CO 80521 (970)221-6700 Rev. 127/12 Submit Two Weeks Prior To Requesting A Certification Of Occupancy For The Property I 1 I00>6�+N:' ,DSQr-Jpm-n �rnrmxl $ggZSmao> O :5 r w�Zrn �='-�N» r� > � O<mX XI S 0 0 rg CAI.t12r.iw u z F� 18;� mm n CD 17 mm c�xnm�>rnW r;-pO-nz0m n ' > gEXZv v z 0:* < 2i"DC C >�DZZ1 �n cn -n FZ�� F Z z v 8 I M xc, `floJ r yo o I r O I 00 r O X0 fi OL6l i 1 00 ED u � W = ;U m 0 0 N O 04 L 049' 1I ry 04C fC1l SITE PLAN CUEI.^r: ENCORE HOMES, LLC SITE: Lot 3, Blk 2, Dry Creels Subdivision 508 Bannock Street, Fort Collins 01 Z CO J00 �nr1 Co O Q I N 00 O Clt - CTL I THOMPSON CTLI THOMPSON INCORPORATED P.970-206-9455 ". 351 Linden Street, Suite M I FF9v 0-206-9441 Fort CeIrms, CO 80524 0fthompson.cam DRAW. SHEET FC05720.224 WEL OF 12-05-2013 1, — 2e. 1 QUALITY _ . _ ' `x ENGINEERING WWW. QUALITY-ENGI NEERI NG. COM CERTIFICATION OF LOT GRADING Date: March 14, 2014 Permit Application No. B1306371 Address: 508 Bannock Street, Fort Collins, CO. Lot/Block/Subdivision: Lot 3, Block 2, Dry Creek Minor Subdivision First Replat Exception: Elevation 36.60' on the northeast side of the lot and elevation 36.43' on the southeast side of the lot differ from the original subdivision grading plans due to as -built construction variances; however, subdivision grading intent is still met. QUALITY ENGINEERING, LLC . (970) 416-7891 1501 ACADEMY CT, SUITE 201 FORT COLLINS, COLORADO