Loading...
HomeMy WebLinkAboutLot Certifications - 06/04/2013 (13)Quality Engineering,,. W W W. QUALITY- ENG I NEERING. BIZ CERTIFICATION OF LOT GRADING Pursuant to Fort Collins City Code § 26-544 and Land Use Code § 3.2.2 (e) Date: May 29. 2013 Permit Application No. B 1300558 Address: 457 Houghton Ct., Fort Collins, CO Lot/Block/Subdivision: Lot 55, Block 4, Dry Creek Minor Subdivision First Replat 1. Cody A. Geisendorter. a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado. has been inspected by me or an appropriately qualified professional under my direct supervision, and verity that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on May 23, 2013. accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information. I certify that (check one): ❑ The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property. X The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exception of: elevation 36.75'. at the southeast corner of the lot, which should beat 36.91', and the elevation 35.847, at the northwest corner of the lot, which should beat 35.917 to maintain a one percent grade along the lot lines (east to west and north to south. respectively). Once corrected, the elevations and grading of the lot/site as constructed will be functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormwater drainage on and off the lot/site in a manner consistent with the approved drainage plan. y ND O Oce T 41326 -n ✓: io rn; Cody A. eisendorfer, PE �0c'*. QUALITY ENGINEERING, LLC (970) 416-7891 1612 LAPORTE AVE, SUITE 7 FORT COLLINS, COLORADO .. ... .______—._. _i . 0 `' 1.9 ,y 1 501-51' 4'E ' 501'51'04'E w j I 21 65.00' •p O � .N -4 •. > r 501 *51'04'E 41.00' 3S� W oto I& 3�d zNm F- 0 4 0 N 4 ,3 SITE PLAN CLIENT: ENCORE HOMES, LW SITE: lAt55.svc4;nryESadc.sa6divLwn 457 Ho9ghtaD Comf FoKCdtim W D �1 m C m m i silo I z 501051'04'E a 65.00 Oa m . I ; a m m -4 W �' m D Z ` --4 cn Olt CTL I THOMPSON P"�`' FC05320.143 0AM- CTL 1 THOMPSON INCORPORA7FD P:670-206-9455 02-04-2ot3 331 Linden Street, Suite 140 F:970-206-9441 0�1 Fort CdRne, CO 80524 W".etltho ps .wm 1' . 20' No Text