CERTIFICATION OF LOT GRADING
Pursuant to Fort Collins City Code § 26-544 and Land Use Code § 3.2.2 (e)
Date: June 25. 2013 I, 3
Permit Application No. B130-0835
Address: 457 Noquet Court, Fort Collins, CO I
Lot/Block/Subdivision: Lot 35. Block 4, Dry Creek Minor Subdivision First Replat
1. Cody A. Geisendorfer, a Colorado registered professional engineer, verify that the above referenced property in
the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my
direct supervision, and verity that construction of all stormwater facilities and grading is complete, and that the
elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed
on approximately June 17, 2013, accurately and truly depict the elevations and drainage patterns as they existed on
the date of the survey. Based on this information, I certify that (check one):
❑ The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved
drainage and grading plan for the property.
X The elevations and drainage patterns of the lot/site as measured are in general conformance with the City
approved drainage plan with exception of: elevation 37.45', at the southeast corner of the home, which
should be at 37.36% as well as elevation 38.247. at the northeast corner of the home. which should be at
38.02', as well as elevation 37.36% at the northwest side of the lot, which should be at 37.14', as well as
elevation 37.30% at the northwest corner of the lot, which should be at 36.88' to maintain a one percent
grade along the lot line (east to west). Once corrected, the elevations and grading of the lot/site as
constructed will be functionally adequate and equivalent to the specifically approved drainage plan, and
will affect stormwater drainage on and off the lot/site in a manner consistent with the approved drainage
plan. pD0 L!C
F F.iys.
�J 6 N F
O,O
0 41326
t d ms
By.-022' Cody A. eisendo�fer, PE ?�� 1NN*AL
QUALITY ENGINEERING, LLC (970) 416-7891 1612 LAPORTE AVE, SUITE 7 FORT COLLINS, COLORADO
w
�0
S m S01'51'04'E 'y
1 21.00' /
501051'04'E
41.00'
O�
T C
va
0) a
r
OO
s
tti -Di
D
W
0
E
N
�(
6010SI'041E 37�.1
6500'
_
GRaQ -
eEirr 6 _, 7-),3
m�
D
m
z �8
J�
1
1
� �•
1
I
L
I
•� n
I
I
. °. .4
: 'p .'
•
m
7.32
�,
cn m �.
5Zl
,c
pON�
r
n
o
I
z
(p c
m 3�
i
�x
o0
0�
-_�
0m
D m -t
1
PI ti
II tn JI}CD
1
V1
1A1'i
V) ;
W
(y�r Ztn '{
I�
9®
CD
�r
m
m
m�
m
m�
Ti (1
-Zi
SITE PLAN
cLMM: ENCORE HOhM LLC
S11E: Lot 35, Blk 4, Dry Crook Subdivision
457 Noquet Cant, Fast COMM
N0I'51'048w
65.00'
cn m
m m�
U)
4-4
CTL I THOMPSON
CTL 1 INOMPSON INCORPORATED P.970-2W-945S
361 Emden Shoat. Suite 140 F:970-206-9441
Fwt Collina, CO 80524 w, .otlthempaen.mm
PMX
FDas32a.1so
;Py'
I _ I1
1 ��
_--- J ;� I I oa 1 4 ova o
T �� I, �Q I J I I J I I
�• I IN If
o < < I r
lop
00--- — sal
0
S. —
cV—
Y .. N }
O m j 1
J o H � S n
(7
0 CV)Z o p TT ♦ J --- LL
o
c
_ I /may �' �. — I `�CD���� I a
o
r
m
O
ys
s O 16
s,
00
co
CL
cao
c
O. I �' E
lop
ID
J
3
• II