Loading...
HomeMy WebLinkAboutLot Certifications - 11/06/2006City of Fort Collins Utilities electric • stormwater • wastewater • water CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: I OG Permit Application No. �. Address: Co Lle4c .Qve- r M2 ke. 1?4 Lot: 1 Block: �.4 Subdivision: I'h&r7cie✓-4,1,d SZy_oCs li'tJ7 STORMWATER RECEIVED NOV 0 2 2006 (,(Print) TDSt'pt7 C S47 4 'a" -<—' , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or someone under my direct supervision, and verify construction of all stormwater facilities and grading is complete, and the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date) Le;2 X06 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, certify that (check one): i� The elevations and drainage patterns of the lot/site are in substantial conformance with the City // approved drainage and grading plan for the property (information attached). SEE NOTE. ❑ The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot as constructed is functionally adequate and will allow for stormwater drainage consistent with the approved drainage plan. SEE NOTE. M /?.. � -"V",l-190 NOTE: A COMPLETE certification must be submitted, including but not limited to drawings of the lot/site showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written information/explanation of discrepancies, etc. to: Fort Collins Utilities (970) 221-6700 700 Wood Street Fort Collins, CO 60621 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property Rev. 111106 Diq'�Ctk'p 11()346 1 li 3 I n� 9� dl I I ww Zp„� 66ww Z a]j I% °1h�E xll I I mwzopa _\� 1yhF� xIl I 3I I�II I syII t�.fIIIIlIIIIlI I�i' o"Q6 "n��Sp�rL�rdZ� Aa3 II III`II nrm a wOm SURVEY 1/0o Fwal IIG o EXISTING SHRUBS 9 v � RECORD W1Sa 5�—--——AOF10/36 ____LLJ2 WO)OUl x LEGEND N rc o Mo EMSTING PIPES 8 INLETS �yjFL PROPOSED PIPE a Q t GLARED ENO SECTION a OL 4 y _` . P V PROPOSED INLET OR OUTLET STRUCTURE p • I F III PROPOSED INLET LOCATION LID _ --____1-- m OJ • S° p Ica' LIMITSa CONSTRUCTION EMSTING 5' CONTOUR Q W �T• �� ^� J (G I ���/ EXISTING 1' CONTOUR �HEf ern. o 5' PROPOSED CONTOUR 6 yy LLI 1, Log U r / PROPOSED 1' CONTOUR W �u/ S ` !! D V / CATCH CURB W/GUTTER W i I t4 = Il RETAINING WALL z Q 7 c !� yj N ^0 I g // I aow MRow �y g 00 OD 6 OO lO0 T{T/ Q /�' FF FINISHED FLOOR crm 10i ri O� c0, �' m LO T U I. Fo• SW SIDEWALK W 4J � I O l9 a hp I ( I GILT GRATE ELEVATION ./ Q 00 r Q Dr) ,0 O 7 O \ OR FINISHED GRADE W In ?to C� /� �J FL FLOW LINE N tr1 FT.� R\ L TC TOP OF CURB//// W TC TOP OF CURB _ w d' 1y �D ` �. I� • r yW HP HIGH PONT W W O ! I O r p ` Q 1- LP LOW PONT - I N N Lfl O T �O (_') %0 III !1( � EC EDGE OF CONCRETE V Tw TOP OF WALL o r to O ^� m °/\�� \ I AS -BUILT SPOT EIEVAYON IN 1 I I oN p li II it �0 to �m o a he ai p6� 1' III p Ej� ^� s N U o \ o � O a III I 10 5 0 10 20 SCALE to In 1 � �o I9s m o� 28ips o III it I1 1 I d� � _ � ry� � J !O � v`�jT III I \ PREPARED unm TIE ollEcr wFLRWBa OT v z NIP . E'i $a\• i!v I Ip � _ _ _ _ __ __III o N RQ � � _ � rt�H� I' I fSs/ONRI f•�O6 J CIXWADO 0.F. N0. 3B6w Fan A w BEHAu W w DEREOWHD i II �I II to 0 N In I cos ��n '11 t ��✓ //' CRY of Fort Collins. Colorado 0 II I• I w �= UTRITY PLAN APPROVAL a\ ti ti 3 II III in a P: a. piNMWDW w 0 F t* CHECKED BT. t m ZED m y a 3 al LL m J I tt, hO} \ NECKED BY:- Wp g q w e CHECKED BY a Rcnur e II ^0 a W to J� ^ Q — — NECKED Bn A n Ia_—g — in 1! O 1. THE NDTEi 00 TOP OF F'WNDAIICN ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS p G.` �`� �_ Or\06 O JI \\\,, M IO } CNI REWIRED FOR PROTECUON FROM THE 1W-YEAR STORM . MINIMUM FINISHED FLOOR IL l ELEVATOR ABOVE THE TW-YEAR WATER SURFACE IN STREETS, CHANNELS. DITCHES. 00' S -O In �I \\ ,00 h_A��I ^ (.� N O SWALES, W OTHER DRAINAGE FACILITIES AS ILLUSTRATED BY A MASTER GRADING I\ R (Fr J V Lyf PLAN ARE TO BE 910NN. hO 9 p 01 \ Q i ` 0. LL > ^ ( Ex Q_ % z. ALL SPOT EIEVAngls DEPICTED ME FLOMllxE UNLESS OTHERWISE NDTm. 01 �. - N� _ 'PG't� \ 3. ALL CURB MD WTTIR S HNL BE -OLI CURB AND GUTTER' UNLESS OTHERWSE \ A, `--- p G° �{ O NOTED. J !., v 1 {. EXISTING UNDERGROUND INSTAIL ATIgb h PRIVATE UUUUES SHOWN ARE IN pCAIED \ ONE I V O �� _ — _ — _ _ _ _ Q w O ACCORDING TO THE BEST INFOMADON AVAILABLE TO THE ENGINEER. ME (_ I� ,3 a ENGINEER DOES NOT GUARANTEE THE ACCURACY CE SUCH INFCRMATCN. SEANCE ((�� ((��V �Y� ` OO,�\ 1 /b ` 0. �0 (� (� !� •(+ rI Q W (n LINES (WATER. POWER. GAS, SigiN MAIN. SANITMY SEWER, PHONE, 1V) MAY NOT [i� W KT/ ('` !� �V��. _� �= v •') O^ ^n. C1R IUi " BE STRAGHT LINES OR AS INDICATED ON THE PLANS. THE COMPACTOR SHALL \ -1 -I V) _ CALL ALL URUTY COMPANIES BEFORE EXCAVAMON FOR EXACT LOCATIONS. ? 1 = 3 — tt Q O O O \ _tn _ � Q 5. ALL WORK TO BE ACCCNPCSHED IN STRICT ADHERENCE WM ALL LOCAL _ _ _ _ _ WTr ORDINANCES, CITY OR STATE. , _ 6. CONTRACTOR APPROPRIATETUTUTYCOMPANES. WORK MINIM PU01L PoLHT-Cf-WAT WI THE 3 COLLEGE A V E• -' ]. ALL MXLF TO BE COORDINATED WTH THE ARCHITECTJRAL PLANS , h O O SHEET T OF i > _ JOB No. 39480.02