Loading...
HomeMy WebLinkAboutLot Certifications - 03/25/1995 (3)3/2,S/5 s- C) ��a C� March 24, 1995 V^ C.L. City of Fort Collins Stormwater Utility Mr. Basil Hamden 235 Mathews Fort Collins, CO 80524 RE: Finished Floor Certification Project No. 10-746-000 Dear Basil: This letter is to certify the finished floor and window well elevations for lot 15, Dakota Ridge, Phase Two. On March 24, 1995, we surveyed said elevation and found that those elevations are as follows: Finished floor elevation=4921.74 and window well elevation=4920.01. According to the approved Utility Drawings dated 9-22-93, the minimum elevation for the finished floor is 4916.50. As you can see, the built finished floor is above this minimum elevation. Therefore, we are requesting the release of the Certificate of Occupancy. We have attached a portion of the Grading, Drainage and Erosion Control Plan for the said lot. If we can answer any questions, please feel free to contact us at any time. Respectfully, TST, INC. CONSUL ING ENGINEERS r ter F. Humann .E. RAD/rsj TST, INC. Consulting Engineers 748 Whalers Way - Building D Fort Collins. CO 80525 (303) 226-0557 Metro Denver (303) 595-9103 Fax (303) 226-0204 I (r Inverness Terrace East Suite 105 Englewood, CO 80112 (303) 792-0557 Fax (303) 792-9489 I I M.H. 114 I � 93 I I Instal/ 4' Diam. Existing lrrigot%on� Standard M.H. I II Ditch Along I , ®I (I 9 Property Line -1,- 82 To Be Removed I I 1-0I lnle 9 1 I LINE 28 Inst I 6' Standard M. fB ` I 41 L.F. Type' Inlet I Install 6' Diom. UNE 34 Standard MN. I 48" R.C.P. 2B L.F. 1 1f12 24�R. C.P. I J 8 MH 17 I / Install 6' Diom \ Standard MH. LINE 2C 1 Jl L.F. 2C 54"`R. C. P. ^ UNE 2 (43 128 L. F. \ _ JJB L. e 54" R.C.P. 42" R. cb Into// 6' Diam. Standard M. H. 4 B _ /. LINE 2A 20' Drainage, ( $ LINE JB 200 L.F. 9' /tility And ` ` 8 L.F. 95 42" R. C. P. M. H.15 1.29 Ac. access Easemen 1B" R. Instal/ 5' Diam. I \ In/et 2C 1 8 1� rj Standard M.H. \ � I Install 9' Standard In/et 2B Type "R` /n/e 1 Install 9' Standc \ \ 4F 1&0 type `R" Inlet �� \ 9, 0.76Ac. ����� 139 j 1 99 \ \ \ 4E I 180 \ 1 \ 1. 19 Ac. \ \ l I 54" R. C.P. 148 \ 4919 I I � � 12 I \ 142 k I 93 J \ 146 \ \ � � I F43 � I 918 \ \ I II I I \ \ 14 ` \ Inlet 4A L — — — I 4:1 Instal/ 1J' Standard I I l7yp•% Type "R" Inlet94 — .r. 18 I UNE 64 166 L.F. I I I 48" R. C. P. (� v Instal/ 4' Concrete 0.8AC. \ __ SEE —Notch Trck/e \ I I ( Pon 0.5' Deep, 18 \ 4" Thick. l I I 16 UNE 64 LINE 64 J6 L.F. I 95 L. F. 7 42" R. C.P. 42" R. C P. 1� 20 Inlet 4,9 I Instaw I I Type /l"R" Standard Inlet