Loading...
HomeMy WebLinkAboutLot Certifications - 09/15/1995t/o/ — /Z C- 0- Mr. Basil Hamden City of Fort Collins Stormwater Utility Department P.O. Box 580 235 Mathews Street Fort Collins, CO 80522-0580 Re: Finished Floor Certification Project No. 10-746-000 Dear Basil: September 15, 1995 This letter is to certify the finished top of foundation and window well elevations for lot 1, D"akota_Ridge,-Phase Two-10n September 13, 1995, we surveyed said elevation and found that those elevations are as follows: Finished top of foundation elevation = 4926.87 and window well elevation = 4925.19. According to the approved Utility Drawings dated September 22, 1993, the minimum elevation for the finished floor is 4916.50. As you can see, the built top of foundation is above this minimum elevation. Also, at the time of our field investigation of said lot 1, we verified that the drainage way improvements as constructed in the final overlot grading and drainage have not been impacted as of this date. These improvements were certified in a letter to you dated May 8, 1995. Said improvements were the low flow concrete drainage pan and rock riprap at the outlet of the drainage culverts under Creekstone Drive. At this time there were not any fences constructed on this lot. Therefore, we are requesting the release of the Certificate of Occupancy. We have attached a portion of the Grading, Drainage and Erosion Control Plan for the said lot. If we can answer any questions, please feel free to contact us at any time. Respectfully, TST, INC. CONSULTING ENGINEERS harlene A. S owen, P.E. RAD/lg TST INC. 748 Whalers Way - Building D 102 Inverness Terrace Fast ! Fort Collins, CO 80525 Suite 105 Consulting Engineers (303) 226-0557 Englewood, CO 80112 Metro Denver (303) 595-9103 (303) 792-0557 Fax (303) 226-0204 Fax (303) 792-9489 3 VUj ji Jr Reg not, II i I I Storm Sewek To Be /nsaa 40` I -- - — By Others. 1 i V I� II , I I.J _ I III � I 1 , I i '1I CRE£KSTONE �I CULVERT Instal/ 70 LF. I 27"x42" Eliptical RCP w/ F.E.S. On Both Ends Down Stream End I Shall Have 20 L.F. 1 Of Type "L` Bum Riprap On Both Sides Of The Pon Extending Up The Bonk 1 Foot. .. ,00;r",\- 1 1 It I , r � + J' , i 1 r Match Existing Concrete Pon And Extend ' To Creekston 1 Culvert LINE 48 27 LF. 240. R.C.P. 189 M.H..112 Install 4' D/am. Standard M.H. 419 r-5 UN£ 4C 1 97 LF. 24` R.C.P. Install concrete I Combination �I Bike Path/Swivle A See Detail On -�9- This Sheet 4 �I �I >.34 Ac. Jr Regional Storm sewer To Be Installed By Others ►1 187 Inlet 54 \ ? 181 1�8 Instal/ 12' Standard Type -R' Inlet 2B ® /14,C. 40 r 0 / // 00000.01- r59 J r .01/ / A 36L4F 24 R.C.P. In/et 5B / M Instal/ 9' Stando Type 'R" Inlet / 167 89 A/.H. /13 — _... .._-.. Instal/ 4' Diam. ^ Standard M.H. .-..., - ....... 158 1.22 I Ac- 90 � 1 1� LINE 4D 402 LF. 240 R.C.P. I 1 o i l i •