Loading...
HomeMy WebLinkAboutLot Certifications - 05/10/2016 (29)7.3' 7.0' 15.2' 7.6' 11.6' 3.3' 0.9' 6.3' 7.6' 3.0' 27.7' 7.0' 7.3' 37.7' 6.0' 84.0' 6.0' 1.0' 37.7' 1.0' 3.3' 6.3' 0.9' 3.0' 4.4' 5.1' U, D & AE U, D, A & EAE U, D, A & EAE U, D, A & EAE N90°00'00"W 95.42' N00°00'00"E 64.00' S90°00'00"E 95.42' S00°00'00"E 64.00' 9.9' 9' UE LaGRANGE AT RIGDEN FARM BG: 12 DRAWN BY: MAK DATE: 04/06/15 No.REVISION BY DATE PROJECT #: 374-008 NOTES: 1. BUILDING IMPROVEMENTS SHOWN ON THIS PLOT PLAN ARE CONCEPTUAL FOR THE SOLE PURPOSE OF OBTAINING A BUILDING PERMIT. REFER TO APPROVED ARCHITECTURAL PLANS FOR CONSTRUCTION OF BUILDING IMPROVEMENTS. 2. ELEVATIONS AND CONTOURS ARE AS SHOWN ON THE ORIGINAL CITY APPROVED GRADING PLAN. DUE TO CIRCUMSTANCES WHICH ARISE SUBSEQUENT TO THE PREPARATION OF THIS SITE PLAN, CONTRACTOR IS ADVISED THAT ELEVATIONS SHOWN HEREON SHOULD BE VERIFIED PRIOR TO CONSTRUCTION. 3. ALL DRAINAGE ARROWS AND PERCENTAGES ARE SHOWN WITHIN DRAINAGE EASEMENTS AND ARE SHOWN FOR CLARITY PURPOSES AND ARE DESIGNED TO HAVE CENTERLINE OF DRAINAGE SWALES INLINE WITH PROPERTY LINE, UNLESS OTHERWISE NOTED. MODEL: LaGRANGE 4 UNIT BASEMENT: NO GARAGE: REAR TOWN: FORT COLLINS COUNTY: LARIMER LOT TYPE: 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com LANDMARK HOMES 1" = 30' 0 FG = 24.50 TF = 25.17 DRIVE 30 15 30 P 4920 4925 4925 4923 20 19 22 21 24 23 24 24 24 26 25 26 25 24 24 23 22 23 22 21 23 22 21 22 21 20 13 14 15 16 17 19 20 18 18 21 17 19 16 20 23 22 21 24 24 25 26 27 26 26 24 25 26 23 22 24 25 24 23 22 21 23 22 21 20 20 22 21 20 19 14 15 16 17 18 19 13 20 22 21 19 24 23 21 20 DES MOINES DRIVE RIGDEN PARKWAY LIMON DRIVE MINNESOTA DRIVE REMOVE EXISTING COLORED CONCRETE PANEL INSTALL TRUNCATED DOME WARNING PER DETAILS REMOVE EXISTING COLORED CONCRETE PANEL INSTALL TRUNCATED DOME WARNING PER DETAILS ROCKFORD DRIVE S T 0 P R1-1 36"x36" STREET NAMEAVE ### BORGERT AQUA-BRIC INTERLOCKING PERMEABLE PAVERS. INTEGRAL COLOR CONTRASTING BRICKS FOR PARKING STRIPES. INSTALL PER MANUFACTURERS SPEC. NO SAND SHALL BE USED. OUTFALL CURB (TYP.) 2' CONCRETE RIBBON (MIN. 6" THICK) \A1;9' R&R TO THIS POINT MATCH EXISTING VERIFY SLOPE (NO SUMP) EDGE OF CONCRETE CONCRETE DRIVE CONCRETE RIBBON 12:1 FROM FOG CONCRETE RIBBON 12:1 FROM FOG OUTFALL CURB (TYP.) 1' PAN W/ 1" DEPRESSION OUTFALL CURB OUTFALL CURB (TYP.) CONTRACTOR TO VERIFY STEPS MEET APPLICABLE CODES BLDG FG=26.50 TF=27.17 FOG=26.90 1 BLDG FG=26.50 TF=27.17 FOG=26.90 2 BLDG FG=26.50 TF=27.17 FOG=25.73 3 BLDG FG=24.50 TF=25.17 FOG=24.90 4 BLDG FG=24.50 TF=25.34 FOG=25.14 5 BLDG FG=24.50 TF=25.17 6 BLDG FG=26.50 TF=27.17 FOG=26.90 3 No. Revisions: By: Date: REVIEWED BY: G. SCHOCK DESIGNED BY: DRAWN BY: SCALE: DATE: 11/06/13 PROJECT: 374-008 Sheet Of 9 Sheets LAGRANGE AT RIGDEN FARM 200 South College Avenue, Suite 010 Fort Collins, Colorado 80524 E N G I N E E R I N G N O R T H E RN PHONE: 970.221.4158 FAX: 970.221.4159 www.northernengineering.com GR1 GRADING PLAN J. Prelog J. Prelog 1"=30' NORTH ( IN FEET ) 1 inch = ft. 30 0 30 Feet 30 60 90 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's below. Call before you dig. R LEGEND: NOTES: 1.EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2.SPOT ELEVATIONS SHOWN ARE FLOWLINE, EDGE OR PAVEMENT, OR EDGE OF WALK UNLESS NOTED OTHERWISE. 3.ALL DISTURBED AREAS SHALL BE REVEGETATED PER THE APPROVED LANDSCAPE PLANS. 4.ALL SOIL (NOT MULCH) IN LANDSCAPE BEDS ADJACENT TO BUILDINGS SHALL BE PLACED SUCH THAT THE TOP OF SOIL IS AT THE SAME ELEVATION AS ADJACENT SIDEWALK TO ALLOW FOR PROPER DRAINAGE. 5.THE FINISHED FLOOR ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. { 6.SEE APPROVED LANDSCAPE PLANS FOR RETAINING WALL SPECIFICATIONS AND DETAILS. } PROPOSED STORM SEWER PROPOSED STORM DRAINAGE INLET 77.71 (77.90) PROPOSED SPOT ELEVATION EXISTING SPOT ELEVATION PROPOSED GRADE 1.8% EXISTING GRADE (1.8%) PROPOSED CONTOURS 80 79 EXISTING STORM SEWER EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 5015 5013 EXISTING RETAINING WALL PROPERTY BOUNDARY EXISTING RIGHT-OF-WAY 1 GARAGE TO FOUNDATION ELEVATIONS ROB 06/11/14 1 1 1 1 1 2 2 CURB CUT & PAN ADDITION ROB 09/30/15 3 3 CURB & GUTTER ALM 12/18/15 EDGE OF FOUNDATION ON PROPERTY LINE